background image

 

 

LISA-U1 series - System Integration Manual 

3G.G2-HW-10002-3 

Preliminary 

Preface  

 

 

Page 3 of 125

 

Preface 

u-blox Technical Documentation 

As  part  of  our  commitment  to  customer  support,  u-blox  maintains  an  extensive  volume  of  technical 
documentation for our products. In addition to our product-specific technical data sheets, the following manuals 
are available to assist u-blox customers in product design and development. 

AT  Commands  Manual:

  This  document  provides  the  description  of  the  supported  AT  commands  by  the  

LISA-U1 series module to verify all implemented functionalities. 

System  Integration  Manual:

 This Manual provides hardware design instructions and information on how to 

set up production and final product tests. 

Application  Note:

  document  provides  general  design  instructions  and  information  that  applies  to  all  u-blox 

Wireless  modules.  See  Section

 

Related  documents

 

for  a  list  of  Application  Notes  related  to  your  Wireless 

Module. 

How to use this Manual 

The LISA-U1 series System Integration Manual provides the necessary information to successfully design in and 
configure these u-blox wireless modules. 
This manual has a modular structure. It is not necessary to read it from the beginning to the end. 
The following symbols are used to highlight important information within the manual: 

 

An index finger points out key information pertaining to module integration and performance. 

 

A warning symbol indicates actions that could negatively impact or damage the module. 

 

Questions 

If you have any questions about u-blox Wireless Integration, please: 

 

Read this manual carefully. 

 

Contact our information service on the homepage 

http://www.u-blox.com

 

 

Read the questions and answers on our FAQ database on the homepage 

http://www.u-blox.com

 

Technical Support 

Worldwide Web 

Our  website  (www.u-blox.com)  is  a  rich  pool  of  information.  Product  information,  technical  documents  and 
helpful FAQ can be accessed 24h a day. 

By E-mail 

Contact the nearest of the Technical Support offices by email. Use our service pool email addresses rather than 
any personal email address of our staff. This makes sure that your request is processed as soon as possible. You 
will find the contact details at the end of the document. 

Helpful Information when Contacting Technical Support 

When contacting Technical Support please have the following information ready: 

 

Module type (e.g. LISA-U100) and firmware version 

 

Module configuration 

 

Clear description of your question or the problem 

 

A short description of the application 

 

Your complete contact details 

Summary of Contents for LISA-U1 Series

Page 1: ...d the integration of the LISA U1 series HSPA wireless modules These modules are a complete and cost efficient 3 75G solution offering high speed dual band HSDPA HSUPA and quad band GSM GPRS voice and...

Page 2: ...tion This document applies to the following products Name Type number Firmware version PCN IN LISA U100 LISA U100 00S 00 10 72 n a LISA U110 LISA U110 00S 00 10 72 n a LISA U120 LISA U120 00S 00 10 72...

Page 3: ...necessary to read it from the beginning to the end The following symbols are used to highlight important information within the manual An index finger points out key information pertaining to module...

Page 4: ...32 1 6 2 Module power off 36 1 6 3 Module reset 37 1 7 RF connection 38 1 8 U SIM interface 39 1 8 1 U SIM functionality 41 1 9 Serial communication 42 1 9 1 Serial interfaces configuration 42 1 9 2 A...

Page 5: ...104 2 4 3 Antenna detection functionality 105 2 5 ESD immunity test precautions 108 2 5 1 General precautions 109 2 5 2 Antenna interface precautions 110 2 5 3 Module interfaces precautions 111 3 Fea...

Page 6: ...ering 119 4 2 7 Hand soldering 119 4 2 8 Rework 119 4 2 9 Conformal coating 119 4 2 10 Casting 120 4 2 11 Grounding metal covers 120 4 2 12 Use of ultrasonic processes 120 5 Product Testing 121 5 1 u...

Page 7: ...red service selectable from GSM to GPRS Optionally paging messages for GSM calls can be monitored during GPRS data transfer in not coordinating NOM II III LISA U1 series modules implement GPRS EGPRS c...

Page 8: ...PA DDC for GPS U SIM Card UART SPI USB GPIO s Power On External Reset V_BCKP RTC Vcc Supply V_INT I O Figure 1 LISA U100 LISA U110 block diagram Wireless Base band Processor Memory Power Management Un...

Page 9: ...high power signal circuitry there are all the low level analog RF components namely Dual band HSxPA WCDMA and quad band EDGE GPRS GSM transceiver Voltage Controlled Temperature Compensated 26 MHz Cry...

Page 10: ...Management Unit PMU used to derive all the system supply voltages from the module supply VCC 32 768 kHz crystal connected to the Real Time Clock RTC oscillator to provide the clock reference in idle o...

Page 11: ...ee section 1 5 4 V_INT 4 O Digital I O Interfaces supply output V_INT 1 8V typical generated by the module when it is switched on and the RESET_N external reset input pin is not forced to the low leve...

Page 12: ...s connected to the application processor See section 1 9 2 CTS 14 O UART clear to send Circuit 106 CTS in ITU T V 24 Provide access to the pin for debugging if the USB interface is connected to the ap...

Page 13: ...ions to ensure compatibility to module supported modes See section 1 11 2 I2S_RXD 44 I I2 S receive data Internal active pull up to V_INT 1 8 V enabled Check device specifications to ensure compatibil...

Page 14: ...13 RSVD 44 N A RESERVED pin Do not connect See section 1 13 RSVD 42 N A RESERVED pin Do not connect See section 1 13 RSVD 41 N A RESERVED pin Do not connect See section 1 13 RSVD 39 N A RESERVED pin D...

Page 15: ...external device If power saving is enabled the module automatically enters idle mode whenever possible Application interfaces are disabled If hardware flow control is enabled the CTS line to ON state...

Page 16: ...nnected Mode Voice or data call enabled Microprocessor runs with 26 MHz as reference oscillator The module is prepared to accept data signals from an external device The module is switched on and a vo...

Page 17: ...V_INT 2 x 3G Power Amplifier s Linear LDO Linear LDO Switching Step Down Linear LDO Linear LDO Linear LDO I O EBU CORE Analog SIM RTC NOR Flash DDR SRAM RF Transceiver Memory Power Management Unit 22...

Page 18: ...o LISA U1 series Data Sheet 1 for specification Name Description Remarks VCC Module power supply input VCC pins are internally connected but all the available pads must be connected to the external su...

Page 19: ...V typ RX slot unused slot unused slot TX slot unused slot unused slot MON slot unused slot RX slot unused slot unused slot TX slot unused slot unused slot MON slot unused slot GSM frame 4 615 ms 1 fra...

Page 20: ...h a maximum voltage that is above the maximum rating for VCC and should therefore be avoided The use of primary not rechargeable battery is uncommon since the most cells available are seldom capable o...

Page 21: ...hreshold e g 60 mA Output voltage slope the use of the soft start function provided by some voltage regulator must be carefully evaluated since the voltage at the VCC pins must ramp from 2 5 V to 3 2...

Page 22: ...inear Technology Table 5 Suggested components for the VCC voltage supply application circuit using a step down regulator Low Drop Out LDO linear regulator The characteristics of the LDO linear regulat...

Page 23: ...must be capable of delivering a DC current greater than the module maximum average current consumption to VCC pins The maximum pulse discharge current and the maximum DC discharge current are not alw...

Page 24: ...s must be carefully evaluated since the voltage at the VCC pins must ramp from 2 5 V to 3 2 V within 1 ms to allow a proper switch on of the module To reduce voltage ripple and noise place the followi...

Page 25: ...on to determine the average current consumption is set by the transmitted power in the transmit slot An example of current consumption profile of the data module in GSM talk mode is shown in Figure 10...

Page 26: ...e continuously due to the Frequency Division Duplex FDD mode of operation with the Wideband Code Division Multiple Access WCDMA The current consumption depends again on output RF power which is always...

Page 27: ...y monitor the paging channel of the current base station paging block reception in accordance to GSM system requirements When the module monitors the paging channel it wakes up to active mode to enabl...

Page 28: ...akes up to active mode to monitor the paging channel for paging block reception 1 5 3 4 2G and 3G fixed active mode power saving disabled Power saving configuration is by default disabled or it can be...

Page 29: ...in the Power Management Unit The output of this linear regulator is always enabled when the main voltage supply provided to the module through VCC is within the valid operating range with the module...

Page 30: ...not required when the VCC supply is removed The date and time will not be updated when VCC is disconnected If VCC is always supplied then the internal regulator is supplied from the main supply and t...

Page 31: ...isabled when the module is switched off or when the RESET_N pin is forced the low level The switching regulator operates in Pulse Width Modulation PWM for high output current mode but automatically sw...

Page 32: ...on level could be required if the line is externally accessible on the application board Higher protection level can be achieved by mounting an ESD protection e g EPCOS CA05P4S14THSG varistor array on...

Page 33: ...istor e g 100 k biased by the V_BCKP supply pin of the module A push pull output of an application processor can also be used in this case the pull up can be used to pull the PWR_ON level high when th...

Page 34: ...d at the VCC pin the module can be switched on by the RTC alarm when the RTC system reaches a pre programmed scheduled time The RTC system will then initiate the boot sequence by instructing the Power...

Page 35: ...Internal Reset Operational Operational Tristate Floating Internal Reset OFF ON Start up event 0 ms 5 ms 6 ms 35 ms 1000 ms PWR_ON can be set high Start of interface configuration All interfaces are co...

Page 36: ...Since the time to perform a network detach depends on the network settings the duration of this phase can differ from the typical value reported in the following figure At the end of the switch off r...

Page 37: ...eset state of all digital pins is reported in the pin description table in LISA U1 series Data Sheet 1 Name Description Remarks RESET_N External reset input Internal 10 k pull up to V_BCKP Table 13 Re...

Page 38: ...RESET_N application circuit 1 7 RF connection The ANT pin has 50 nominal characteristic impedance and must be connected to the antenna through a 50 transmission line to allow transmission and recepti...

Page 39: ...terface pins A low capacitance i e less than 10 pF ESD protection e g Infineon ESD8V0L2B 03L or AVX USB0002RP must be placed near the SIM card holder on each line VSIM SIM_IO SIM_CLK SIM_RST The SIM i...

Page 40: ...gh by the pull up resistor connected to V_INT i e the switch integrated in the SIM connector is closed LISA U1 series C1 SIM CARD HOLDER CCVCC C1 CCVPP C6 CCIO C7 CCCLK C3 CCRST C2 GND C5 C2 C3 C5 D2...

Page 41: ...ns is the maximum allowed rise time on the SIM_CLK line 1 0 s is the maximum allowed rise time on the SIM_IO and SIM_RST lines always route the connections to keep them as short as possible 1 8 1 U S...

Page 42: ...presents the data terminal equipment DTE All the interfaces listed above are controlled and operated with AT commands according to 3GPP TS 27 007 4 AT commands according to 3GPP TS 27 005 5 AT command...

Page 43: ...AT K3 HW flow control enabled AT S1 DSR line set ON in data mode and set OFF in command mode AT D1 Upon an ON to OFF transition of DTR the DCE enters online command state and issues an OK result code...

Page 44: ...t 106 Ready for sending in ITU T V 24 TxD Transmitted data Module data input Circuit 103 Transmitted data in ITU T V 24 Internal active pull up to V_INT 1 8 V enabled RxD Received data Module data out...

Page 45: ...signal behavior AT commands interface case See Table 3 for a description of operating modes and states referred to in this section At the switch on of the module before the initialization of the UART...

Page 46: ...FCon FCoff MUX command for flow control issues outside the power saving configuration while the physical CTS line is still used as a power state indicator For more details please refer to Mux Impleme...

Page 47: ...mand mode to data mode and can accept PPP packets The module sets the DCD line to the ON state then answers with a CONNECT to confirm the ATD 99 command Please note that the DCD ON is not related to t...

Page 48: ...ure 23 if the feature is enabled by the proper AT command please refer to u blox AT Commands Manual 2 AT CNMI command Figure 23 RI behavior at SMS arrival This behavior allows the DTE to stay in power...

Page 49: ...ke up time of the module As a consequence the first character sent when the module is in idle mode i e the wake up character won t be a valid communication character because it can t be recognized and...

Page 50: ...ot been received or sent the UART is disabled for 2 5 s and afterwards the interface is enabled again When UART interface is disabled data transmitted by the DTE will be lost if hardware flow control...

Page 51: ...T power saving mode when it is enabled disabled Wake up from idle mode to active mode via data reception If data is transmitted by the DTE during the module idle mode it will be lost not correctly rec...

Page 52: ...mes 9 2s after the last data received time Wake up time up to 15 6 ms time TxD module input Wake up character Not recognized by DCE Valid characters Recognized by DCE Figure 26 Wake up via data recept...

Page 53: ...tionality conforming to ITU Recommendation 3 in DTE DCE serial communication the complete UART interface of the module DCE must be connected to the DTE as described in Figure 27 LISA U1 series DCE TxD...

Page 54: ...TP Figure 28 UART interface application circuit with partial V 24 link 5 wire in the DTE DCE serial communication If only TxD RxD RTS and CTS lines are provided as described in Figure 28 the procedur...

Page 55: ...s active mode 20 ms after a low to high transition on the TxD input line the recognition of the subsequent characters is guaranteed until the module is in active mode Data delivered by the DTE can be...

Page 56: ...SB USB_D USB Data Line D 90 nominal differential impedance Pull up or pull down resistors and external series resistors as required by the USB 2 0 high speed specification 7 are part of the USB pad dr...

Page 57: ...st Remote wake up is accomplished using electrical signaling described in the Universal Serial Bus Revision 2 0 specification 7 When the USB enters suspended state the average VCC module current consu...

Page 58: ...the PWR_ON pin or enable the DC supply connected to the VCC pin to start the module firmware upgrade see Firmware Update Application Note 16 If the USB interface is not used the USB_D USB_D and VUSB_...

Page 59: ...terface without specific configuration The SPI device shall look for all upper SW layers like any other serial device This means that LISA U1 series modules emulate all serial logical lines the transm...

Page 60: ...The number of clock periods sent by the master is exactly that one of the frame size to be transferred The SPI_SRDY line will be set low after the master sets the clock line to idle state The SPI_MRDY...

Page 61: ...a transfer initiated by application processor master with a sleeping LISA U1 series module slave When the slave is sleeping idle mode the following actions happen 1 The Master wakes the slave by setti...

Page 62: ...e output for the module since it runs as SPI slave it must be connected to the data line input MISO of the application processor that runs as an SPI master SPI_SCLK is the clock input for the module s...

Page 63: ...DDC interface for communication with u blox GPS receivers is available on LISA U1 series modules This interface is dedicated exclusively to access u blox GPS receivers Name Description Remarks SCL I2...

Page 64: ...ata line Since both lines are open drain outputs the DDC devices can only drive them low or leave them open The pull up resistor pulls the line up to the supply rail if no DDC device is pulling it dow...

Page 65: ...ported by upcoming FW version LISA U1 series R1 IN OUT GND GPS LDO Regulator SHDN u blox 1 8 V GPS receiver SDA2 SCL2 R2 1V8 1V8 VMAIN 1V8 U1 21 GPIO2 SDA SCL C1 TxD1 EXTINT0 GPIO3 GPIO4 46 45 23 24 V...

Page 66: ...bus Bidirectional Voltage Translator PCA9306DCURG4 Texas Instruments U3 Generic Bidirectional Voltage Translator TXB0104PWR Texas Instruments Table 26 Components for DDC application circuit for u blox...

Page 67: ...enabled the wireless module automatically uploads data such as position time ephemeris almanac health and ionospheric parameter from the GPS receiver into its local memory and restores back the GPS re...

Page 68: ...al to analog converter The analog audio output is selected when the parameter main_downlink in AT USPM command is set to Normal earpiece Mono headset or Loudspeaker the downlink analog path profiles u...

Page 69: ...ing a headset with a 2 2 k electret microphone and a 32 receiver to the LISA U120 and LISA U130 modules with an external low noise LDO voltage regulator to provide a proper supply for the microphone M...

Page 70: ...y for the microphone Mount an 82 nH series inductor e g Murata LQG15HS82NJ02 on each microphone line and a 27 pF bypass capacitor e g Murata GRM1555C1H270J on all audio lines to minimize RF coupling a...

Page 71: ...voice band handling echo canceller and automatic gain control managed via software refer to u blox AT commands manual 2 AT UHFP command Figure 39 shows an example of an application circuit connecting...

Page 72: ...10V GRM155R71C104KA01 Murata D1 D2 Low Capacitance ESD Protection USB0002RP or USB0002DP AVX J1 Microphone Connector J2 Speaker Connector L1 L2 82nH Multilayer inductor 0402 self resonance frequency 1...

Page 73: ...o device For example in case of differential input impedance of 600 the two 10 F capacitors will set the 3 dB cut off frequency to 53 Hz while for single ended connection to 600 external device the cu...

Page 74: ...5 0 1 W RC0402JR 070RL Yageo Phycomp R2 R4 Not populated Table 31 Connection to an Audio Device 1 11 2 Digital Audio interface LISA U120 and LISA U130 modules support a bidirectional 4 wire I 2 S digi...

Page 75: ...lgorithm acts on I 2 S path Refer to the u blox AT Commands Manual 2 AT UI2S command for possible settings of I 2 S interface 1 11 2 1 I 2 S interface PCM mode Main features of the I 2 S interface in...

Page 76: ...l interface The analog amplifiers are skipped in this case Possible processing of audio signal are Speech encoding uplink and decoding downlink The following speech codecs are supported in firmware on...

Page 77: ...which summarizes the voiceband audio processing in the DSP DAC ADC I2S_RXD Switch MIC Microphone Analog Gain UF 2 UF 1 Hands free To Radio TX Scal_Mic Digital Gain Sidetone SPK_P N Switch I2S_TXD Scal...

Page 78: ...gured to provide the GPS supply enable function is set as o Output High to switch on the u blox GPS receiver if the parameter mode of AT UGPS command is set to 1 o Output Low to switch off the u blox...

Page 79: ...simultaneously set the same mode on another pin also on all the GPIOs None GPIO pin is by default configured as General purpose input The pin configured to provide the General purpose input function...

Page 80: ...detection function Can be alternatively configured by the AT UGPIOC command as Output Input Network Status Indication GPS Supply Enable Pad disabled Table 33 GPIO pins The GPIO pins ESD sensitivity ra...

Page 81: ...lder CCM03 3013LFT R102 C K Components or equivalent R4 10 k Resistor 0402 5 0 1 W Various manufacturers R5 47 k Resistor 0402 5 0 1 W Various manufacturers R6 820 Resistor 0402 5 0 1 W Various manufa...

Page 82: ...S RTC sharing function to provide a RTC Real Time Clock synchronization signal to the u blox GPS receiver connected to the wireless module setting the parameter gpio_mode of AT UGPIOC command to 5 The...

Page 83: ...re use All the RSVD pins except pin number 5 can be left unconnected on the application board The application circuit is illustrated in Figure 44 Pin 5 RSVD must be connected to GND LISA U120 U130 5 R...

Page 84: ...58 SPI_SRDY GND VBUS D D GND 18 VUSB_DET 27 USB_D 26 USB_D GND 100nF 5 RSVD 52 RSVD 74 RSVD GND RTC back up 27pF 27pF 27pF 82nH 54 SPK_N 53 SPK_P 39 MIC_N 40 MIC_P ESD Headset Connector ESD IN OUT GN...

Page 85: ...TTED and European Conformance CE mark Products bearing the CE marking comply with the R TTE Directive 99 5 EC EMC Directive 89 336 EEC and the Low Voltage Directive 73 23 EEC issued by the Commission...

Page 86: ...minimum distance of 20 cm between the radiator and your body This transmitter must not be co located or operating in conjunction with any other antenna or transmitter 1 15 3 3 Modifications The FCC r...

Page 87: ...t RSS 210 Son fonctionnement est soumis aux deux conditions suivantes o cet appareil ne doit pas causer d interf rence o cet appareil doit accepter toute interf rence notamment les interf rences qui p...

Page 88: ...cess to USB interface and or to UART RxD TxD lines and access to PWR_ON and or RESET_N lines on the application board in order to flash upgrade the module firmware Provide appropriate access to USB in...

Page 89: ...rom DC source for VCC Design USB_D USB_D connection as 90 differential pair Keep routing short and minimize parasitic capacitance on the SPI lines to preserve signal integrity 2 1 3 Antenna checklist...

Page 90: ...NT RSVD GND GND GND DSR RI DCD DTR GND RTS CTS TXD RXD GND VUSB_DET PWR_ON GPIO1 GPIO2 RESET_N GPIO3 GPIO4 GND USB_D USB_D 2 3 4 5 6 7 8 9 10 11 12 1 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 GND V...

Page 91: ...RI DCD DTR External Reset RESET_N General Purpose I O GPIO1 GPIO2 GPIO3 GPIO4 GPIO5 USB detection VUSB_DET Supply for Interfaces V_INT Table 35 Pin list in order of decreasing importance for layout d...

Page 92: ...on line and the adjacent GND area on the same layer does not exceed 5 times the track width of the micro strip use the Coplanar Waveguide model for 50 characteristic impedance calculation Don t route...

Page 93: ...series modules has a structure of four layers described in the following The Layer 1 top layer see Figure 48 provides a micro strip line to connect the ANT pin of the LISA U1 series module to the ant...

Page 94: ...er is 0 76 mm The Layer 3 inner layer described in Figure 50 is designed for signals routing and GND plane Layer 3 thickness is 0 035 mm Figure 50 Layer 3 inner layer of u blox approved interface boar...

Page 95: ...r the overall performance and functionality of the integrated product For detailed description check the design guidelines in section 1 5 2 Some main characteristics are VCC pins are internally connec...

Page 96: ...maximum ratings are not exceeded place the protecting device along the path from the DC source toward the LISA U1 series module preferably closer to the DC source otherwise functionality may be compro...

Page 97: ...g PCB lines to reduce series resistive losses when the audio output is directly connected to low impedance speaker transducer Use twisted pair cables for balanced audio usage If DC decoupling is requi...

Page 98: ...channels whose carrier frequency is coincidental with harmonic frequencies The latter case placing the RF bypass capacitors suggested in Figure 20 near the SIM connector will mitigate the problem In a...

Page 99: ...nt and paste mask To improve the wetting of the half vias reduce the amount of solder paste under the module and increase the volume outside of the module by defining the dimensions of the paste mask...

Page 100: ...d Figure 53 Signals keep out area on the top layer of the application board below LISA U1 series modules 2 2 3 Placement Optimize placement for minimum length of RF line and closer path from DC source...

Page 101: ...e call at maximum power 19 C during GPRS data transfer with 4 TX slots 16 C during EDGE data transfer with 4 TX slots up to 25 C in UMTS connection at max TX power Case to Ambient thermal resistance v...

Page 102: ...ected If the LISA U100 U120 modules are planned for use on the entire supported bands then a dual band antenna 824 894 MHz 1850 1990 MHz should be selected Otherwise for fixed applications in specific...

Page 103: ...ds Therefore to reduce as much as possible performance degradation due to antenna mismatch the following requirements should be met Measure the antenna termination with a network analyzer connect the...

Page 104: ...deband log periodic like antenna was used and the comparison was done with a half lambda dipole tuned at 900 MHz frequency The measurements show both the S11 and S21 for the penta band internal antenn...

Page 105: ...works in combination with a ground plane The ground plane ideally infinite can be reduced down to a minimum size that must be similar to one quarter of the wavelength of the minimum frequency that has...

Page 106: ...monopole or a DC short to reference GND e g PIFA antenna For those antennas without the diagnostic circuit of Figure 58 the measured DC resistance will always be at the limits of the measurement rang...

Page 107: ...ommands Manual 2 means that that the antenna is not connected or the RF cable is broken Reported values below the measurement range minimum limit 1 k will highlight a short to GND at antenna or along...

Page 108: ...al coupling planes 10 Implement the following precautions to satisfy ESD immunity test requirements 10 11 12 performed at the device enclosure in compliance to the category level 11 and shown in the f...

Page 109: ...depending on the application board handling The following precautions are suggested RESET_N pin Sensitive interface is the reset line RESET_N pin A 47 pF bypass capacitor e g Murata GRM1555C1H470JA01...

Page 110: ...ass capacitor e g Murata GRM1555C1H470J have to be mounted on the lines connected to VSIM SIM_RST SIM_IO and SIM_CLK to assure SIM interface functionality when an electrostatic discharge is applied to...

Page 111: ...fy ESD immunity test requirements and ESD category level pins connected to the port should be protected up to 4 kV 4 kV for direct Contact Discharge and up to 8 kV 8 kV for Air Discharge applied to th...

Page 112: ...rt or simultaneously through the virtual serial ports of the multiplexer multiplexing mode MUX with the following constraints Using the MT s embedded TCP IP stack only 1 internal PDP context is suppor...

Page 113: ...be generated automatically or manually following an car accident using GSM cellular service 112 When activated the in vehicle eCall system IVS creates an emergency call carrying both voice and data e...

Page 114: ...mits see Figure 61 named t 2 t 1 t 1 and t 2 Within the first limit t 1 Ti t 1 the wireless module is in the normal working range the Safe Area In the Warning Area t 2 Ti t 1 or t 1 Ti t 2 the wireles...

Page 115: ...Yes Send shutdown notification Feature enabled full logic or indication only IF Full Logic Enabled Feature disabled no action Temperature is within normal operating range Yes Tempetature is within war...

Page 116: ...41 Symbol Parameter Temperature Remarks t 2 Low temperature shutdown 40 C Equal to the absolute minimum temperature rating for the wireless module the lower limit of the extended temperature range t 1...

Page 117: ...ure 217 C Stencil Thickness 120 m for base boards The final choice of the soldering paste depends on the approved manufacturing procedures The paste mask geometry for applying soldering paste should m...

Page 118: ...ture fall rate max 4 C s To avoid falling off modules should be placed on the topside of the motherboard during soldering The final soldering temperature chosen at the factory depends on additional ex...

Page 119: ...2 5 Repeated reflow soldering Only a single reflow soldering process is encouraged for boards with a LISA U1 series module populated on it The reason for this is the risk of the module falling off du...

Page 120: ...other forms of metal strips directly onto the EMI covers is done at the customer s own risk The numerous ground pins should be sufficient to provide optimum immunity to interferences and noise u blox...

Page 121: ...ed in detail to improve the production quality This is achieved with automatic test equipment which delivers a detailed test report for each unit The following measurements are done Digital self test...

Page 122: ...ata Terminal Equipment DTM Dual Transfer Mode DTR Data Terminal Ready EBU External Bus Interface Unit EDGE Enhanced Data rates for GSM Evolution E GPRS Enhanced GPRS FDD Frequency Division Duplex FEM...

Page 123: ...Indicator RTC Real Time Clock RTS Request To Send RXD RX Data SAW Surface Acoustic Wave SIM Subscriber Identification Module SMS Short Message Service SMTP Simple Mail Transfer Protocol SPI Serial Per...

Page 124: ...measurement techniques Electrostatic discharge immunity test 11 ETSI EN 301 489 1 V1 8 1 Electromagnetic compatibility and Radio spectrum Matters ERM ElectroMagnetic Compatibility EMC standard for ra...

Page 125: ...Europe Middle East Africa u blox AG Phone 41 44 722 74 44 E mail info u blox com Support support u blox com Asia Australia Pacific u blox Singapore Pte Ltd Phone 65 6734 3811 E mail info_ap u blox com...

Reviews: