Installation Requirements
• Clear line of sight between airFiber AP and station
• Clear view of the sky for proper GPS operation
• Vertical mounting orientation
• Mounting point:
• At least 1 m below the highest point on the structure
• For tower installations, at least 3 m below the top of
the tower
• Outdoor, shielded Category 6 (or above) cabling and
shielded RJ45 connectors are required for all wired Ethernet
connections.
• Surge protection should be used for all outdoor installations.
We recommend that you use two Ethernet Surge Protectors,
model ETH-SP-G2, one near the airFiber radio and the other
at the entry point to the building. The ETH-SP-G2 will absorb
power surges and safely discharge them into the ground.
Note:
For guidelines about grounding and lightning
protection, follow your local electrical regulatory
codes.