![Ubiquiti airFiber 24 User Manual Download Page 17](http://html.mh-extra.com/html/ubiquiti/airfiber-24/airfiber-24_user-manual_833431017.webp)
13
Chapter 2: Installation
airFiber AF-24/AF-24HD User Guide
Ubiquiti Networks, Inc.
Alignment
Tips
• Fine-tuning is best achieved by a pair of installers with
a dedicated, two-way communication link: one installer
makes adjustments on one airFiber radio while the other
installer reports the received signal level at the other
airFiber radio. Fine-tuning (see
“Fine-Tuning the Link”
on page 15
) is necessary because the main lobe of
the receiver is narrower than that of the transmitter, in
both azimuth and elevation.
• To accurately align the airFiber radios for best
performance, you MUST align only one end of the link at
a time.
• For more convenient alignment, you may consider using
long-range scopes (not included) temporarily attached
to your airFiber radios.
• You may need to use additional hardware to
compensate for issues such as the improper orientation
of a mounting pole or significant elevation differences
between the airFiber radios.
Determining the Received Signal Level
There are three ways to determine the received signal
level:
• LED Display (See the following section,
Using the LED
Display
.)
• airFiber Configuration Interface (See
“Using the
airFiber Configuration Interface” on page 15
.)
• Audio tone (Optional equipment required. See
“Using
the Audio Tone” on page 18
.)
Using the LED Display
Establishing a Preliminary Link
Adjust the positions of the
Master
and the
Slave
to
establish a preliminary link. This requires the
Master
and
Slave
to be within a few degrees of the line of sight
between the airFiber radios.
Note:
The
Master
must be aimed first at the
Slave
because the
Slave
does not transmit any RF signal
until it detects transmissions from the
Master
.
1. For the
Master
and
Slave
, ensure the eight
Lock Bolts
on
the
Alignment Bracket
are sufficiently loose by spinning
each washer by hand.
WARNING:
All
Lock Bolts
MUST be loose to avoid
damage to the airFiber housing.
2. For the
Master
and
Slave
, ensure the
Azimuth (AZ)
and
Elevation (EL) Adjustment Bolts
are in the middle of their
adjustment ranges.
Elevation (EL)
Adjustment Bolt
Azimuth (AZ)
Adjustment Bolt
Summary of Contents for airFiber 24
Page 1: ...24 GHz Point to Point Radio Models AF 24 AF 24HD ...
Page 2: ......
Page 24: ...20 Chapter 2 Installation airFiber AF 24 AF 24HD User Guide Ubiquiti Networks Inc ...
Page 28: ...24 airFiber AF 24 AF 24HD User Guide Ubiquiti Networks Inc ...
Page 32: ...28 Chapter 4 Dashboard airFiber AF 24 AF 24HD User Guide Ubiquiti Networks Inc ...
Page 36: ...32 Chapter 5 Wireless Tab airFiber AF 24 AF 24HD User Guide Ubiquiti Networks Inc ...
Page 40: ...36 airFiber AF 24 AF 24HD User Guide Ubiquiti Networks Inc ...
Page 44: ...40 Chapter 7 Services Tab airFiber AF 24 AF 24HD User Guide Ubiquiti Networks Inc ...
Page 48: ...44 Chapter 8 System Tab airFiber AF 24 AF 24HD User Guide Ubiquiti Networks Inc ...
Page 54: ...50 Chapter 9 Tools airFiber AF 24 AF 24HD User Guide Ubiquiti Networks Inc ...
Page 60: ...56 Appendix B Safety Notices airFiber AF 24 AF 24HD User Guide Ubiquiti Networks Inc ...
Page 68: ...w w w u b n t c o m ...