1. This portable heater is intended for outdoor use only.
    Always ensure that adequate  fresh air ventilation is

provided.

1. Perodically check the whole gas system for leaks.
2. Immediately check for leaks if an odour of gas is detected.
3. Extinguish all open flames during testing or when an odour
    of gas is detected.
4. Never smoke while performing the leak test.
5. If you cannot stop a leak, unscrew and remove the cylinder
    from the heater.
6. The heater must be checked with a full propane cylinder.
    DO NOT use the heater until you have performed a leak
    test on all the connections and verified that your unit does
    not leak.
7. Use only manufacturer recommended replacement parts. 
    Substitution may void the warranty.

1. Open the valve on the gas supply cylinder completely.
2. Firmly press down and turn the variable control knob
    approximately 45°(counter clockwise).
3. Press down the variable control knob and hold for 20 
    seconds while holding down the variable control knob, 
    press the igniter button several times until the pilot flame 
    comes on. Release the variable control knob after the 
    pilot flame lights.
4. If the pilot does not light, repeat step 2 to 3.
   Note: If a new tank has just been connected, please allow at
   least one minute for the air in the gas pipeline to purge out
   through the pilot hole.
5. After the flame comes on, leave the variable control knob at
   minimum position for about 5 minutes, then turn knob to set
   desired heat level.

1. Turn control knob to “PILOT” position.
2. Press down lightly and turn to “OFF” position.
3.Turn the gas tank off completely.

Variable Control Knob

2. Always maintain proper clearance with combustible
    materials, i.e. top 24 inches and  sides 36 inches
    minimum.
3. The heater must be put on a solid and stable surface.
4. Never operate the heater in an explosive atmosphere
    like in areas where gasoline or other flammable liquids
    or vapours are stored.

   Gas connections on this heater are leak tested at the

factory prior to shipment. Possible mishandling of this

appliance during shipping may impair product integrity.
A complete leakage test must be performed again at the
installation site. Please follow the procedure below.
  

1. Make a soap solution of one part liquid detergent and
    one part water.  The soap solution can be applied to
    hoses and connections with a spray bottle, brush or rag.
  

2. Make sure that the safety control valve is in the "OFF"
    position.
  

3. Turn the cylinder valve ON and check for soap bubbles
   forming on and around connections and hoses. If bubbles
   appear, there is a leak present.
  

4. If a leak is present, remove the gas cylinder immediately,
    tighten any leaking fittings, replace the gas cylinder, and
    recheck.
  

  

Portable Heater Location

Turning Heater ON

Turning the Heater and Pilot Light OFF

Procedure for Leakage Test

Testing for Leakage

O

L

t

oli

P

I

H

O

L

t

oli

P

I

H

O

L

t

oli

P

I

H

36”

24”

Summary of Contents for HPS-C-GH

Page 1: ...er Keep this manual and the original sales invoice in a safe dry place for future reference Notre personnel du service la client le est disponible pour vous aider En cas de probl me avec votre achat o...

Page 2: ...G indicates an imminently hazardous situation which if not avoided could result in death or serious injury DANGER WARNING CAUTION CAUTION indicates an imminently hazardous situation which if not avoid...

Page 3: ...ards of CANADA CAN CGA B 149 2 DANGER RBO1 MONOXID HAZARD This heater is a combustion appliance All combustion appliances produce carbon monoxide CO during the combustion process This product is desig...

Page 4: ...o the burner Keep flammables at least 91 cm 36 from sides 24 61 cm from top Keep gasoline and other flammable liquids and vapours well away from heater The propane cylinder must always be stored outdo...

Page 5: ...ng weight 8 M6X20 bolts qty 4 9 3 16 Stainless bolts qty 4 and washers qty 4 10 Post with burner assembly 11 3 16 Stainless bolts qty 4 12 M5X10 bolt and washer qty 1 13 Heater housing 14 Washers qty...

Page 6: ...15mm bolts and fix the Tank housing to the base Tighten the bolts as shown below Put the Burner on the Tank Housing then attach with 4 3 16 bolts Fix the Regulator to the Tank Housing with each one of...

Page 7: ...ust caps tightly installed and must not be stored in a building garage or any other enclosed area Standard 1 02 lb tank 6 Close the door plate and lock it with the handle The cylinder must be disconne...

Page 8: ...on leave the variable control knob at minimum position for about 5 minutes then turn knob to set desired heat level 1 Turn control knob to PILOT position 2 Press down lightly and turn to OFF position...

Page 9: ...han 40 F and tank is less than 1 4 full Use a full cylinder e g a k c o l b r o f s e c i f i r o d n a r e n r u b k c e h C on HI b o n k l o r t n o C Carbon build up Dirt or film on reflector and...

Page 10: ...l snow dust and debris If desired cover heater to protect exterior surfaces and to help prevent build up in air passages Never leave LP cylinder exposed to direct sunlight or excessive heat Note Wait...

Page 11: ...d entra ner la mort ou de graves blessures corporelles DANGER MISE EN GARDE AVERTISSEMENT AVERTISSEMENT Le terme AVERTISSEMENT signifie une situation dangereuse imminente qui faute d tre vit e serait...

Page 12: ...OD JULSSH GHV HX ODUPR DQWV GHV PDX GH WrWH GHV YHUWLJHV GH OD IDWLJXH YRLUH OD PRUW QFRORUH HW LQRGRUH OH 2 WXH Q SUpVHQFH GH FHV V PSW PHV ORUV GH O XWLOLVDWLRQ GH O DSSDUHLO DOOH LPPpGLDWHPHQW DX...

Page 13: ...z que des bonbonnes munies d un dispositif d vacuation de la vapeur HQWUHSRVDJH HW O XWLOLVDWLRQ GX JD SURSDQH GRLYHQW rWUH ex cut s dans le respect des arr t s locaux des codes locaux ou de la norme...

Page 14: ...15 R gulateur 16 Tiges et crous 3 Outils n cessaires pour l assemblage 1 Tournevis Phillips 2 Cl molette 3 Flacon pulv risateur avec solution savonneuse pour effectuer les tests de d tection de fuite...

Page 15: ...lons M6X15mm et fixez le bo tier du radiateur la base et l anneau en fonte Serrez les boulons tel qu illustr D posez le br leur sur le bo tier du radiateur puis fixez les avec les 4 boulons de 3 16 Fi...

Page 16: ...solidement fix s et ne doit pas tre rang e dans un b timent un garage ou tout autre endroit clos Bonbonne standard de 1 02 lb 15 Fermez le panneau d acc s et verrouillez le avec la poign e La bonbonn...

Page 17: ...veilleuse est allum e laissez le bouton de commande en position minimum pendant environ 5 minutes ensuite r glez le la temp rature d sir e 1 Tournez le bouton de commande PILOT 2 Appuyez l g rement s...

Page 18: ...a capacit Utilisez une bonbonne pleine V rifiez si le br leur et des orifices ne seraient pas obstru s Le bouton de commande est HI Accumulation de carbone Salet ou d p ts sur le r flecteur et le gril...

Page 19: ...eur de chaleur ni sur le d me ENTREPOSAGE Entre chaque utilisation Tournez le bouton de commande OFF D branchez la bonbonnede propane Entreposez l appareil debout dans un endroit prot g l abri des int...

Reviews: