background image

®

Fuel transFer pump 12vdc

98135

set up and Operating instructiOns

distributed exclusively by Harbor Freight tools

®

.

3491 Mission Oaks Blvd., Camarillo, CA 93011

visit our website at: http://www.harborfreight.com

 read this material before using this product.  

Failure to do so can result in serious injury. 

save tHis manual.

Copyright

©

 2008 by Harbor Freight Tools

®

.  All rights reserved.  No portion of this manual or any 

artwork contained herein may be reproduced in any shape or form without the express written 

consent of Harbor Freight Tools.  Diagrams within this manual may not be drawn proportionally.  Due 

to continuing improvements, actual product may differ slightly from the product described herein.

For technical questions or replacement parts, please call 1-800-444-3353.

Summary of Contents for 98135

Page 1: ...serious injury Save this manual Copyright 2008 by Harbor Freight Tools All rights reserved No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the...

Page 2: ...ates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE is used to address practices not related to personal injury CAUTION without the safety alert symbol is u...

Page 3: ...allow children to operate it Do not wear clothing made from 8 synthetic fibers There is danger from static electricity build up causing sparks that could lead to fire or explo sion Place empty contai...

Page 4: ...unreadable or miss ing contact Harbor Freight Tools for a replacement Save these instructions Specifications Application Permanent Magnetic Motor pumps diesel Kerosene Light weight oils water and anti...

Page 5: ...een installed on tank barrel or drum When installed at tach parts as in steps two and three Wrench tighten all connections 5 Functions This Fuel Transfer Pump is com 1 patible and may be used with the...

Page 6: ...opening Install the Hose 55 and Nozzle 54 4 See Assembly Instructions on page 6 of this manual Connect the Cable 60 that extends 5 from the Cable Connector 53 Make sure to connect the Ground Wire 51 T...

Page 7: ...ce Support the Cable 60 as necessary and protect it from heat sharp edges or any other obstacle that could dam age it Strip the outer Cable 60 covering 8 as necessary Make a secure con nection to the...

Page 8: ...ck of 1 container being filled to reduce static electricity buildup On initial start up it may be necessary 2 to hold the Nozzle 54 open a few seconds to allow pump to prime Remove Nozzle 54 from Pump...

Page 9: ...1 inspect the general condition of the Pump Check for loose screws loose or bro ken electrical wiring and any other condition that may affect its safe operation Maintain labels and nameplates on 2 th...

Page 10: ...Valve 28 sticking 3 Vanes 33 sticking 4 Excessive Rotor 34 or Vane 5 33 wear Hose 55 damage 6 Remove and clean Screen 25 1 Check Suction Pipe 58 for leaks or 2 restrictions Remove and inspect Bypass V...

Page 11: ...lace if needed with identical part by qualified technician Fluid leakage Bad O Ring or Gasket 1 Dirty shaft seal 2 Bad shaft seal 3 Incompatible fluid 4 Check all O Rings and Gaskets 1 See Parts List...

Page 12: ...ad 1 22 10 24 X 3 4 Star Screw 6 23 5 32 X 1 2 Pin 1 24 Inlet Flange 1 25 Screen 1 26 Inlet Gasket 1 27 Check Valve Assembly 1 28 Bypass Valve 1 29 Bypass Valve Gasket 1 30 Bypass Spring 1 PARTS LIST...

Page 13: ...3353 ASSEMBLY DIAGRAM Record Product s Serial Number Here Note If product has no serial number record month and year of purchase instead Note Some parts are listed and shown for illustration purposes...

Page 14: ...ecial or consequential damages arising from the use of our product Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limita tion of exclusion may...

Reviews: