37
109838-01 - 5/20
X-PV
Installation, Operating & Service Manual
STATUS MODE
:
=Current Status (Table 11.3)
Press and Hold
I
,
↑
, and
↓
for at least 3
sec to enter
ADJUSTMENT MODE
Press
I
to enter
OPERATING MODE
= Current Boiler Temp.
=Call for Heat? (On/Off)
= Limit Differential
= High Limit Setting
= Current Set Point
=Call for DHW? (On/Off)
=Flame Signal (uA)
ERROR MODE
(Visible when Lockout is Present)
= Code for Error Present (Table 13.0)
=total burner Cycles
=Total Run Time (hrs)
Press
I
=Return to Status Mode
Press
↑
or
↓
Boiler in
Lockout?
=Temperature Units
=Reset
=Circulator Overrun
= High Limit Setting
= Limit Differential
=Thermal Purge Temp
=Thermal Purge Time
=DHW Priority (ON/OFF)
=Use of 2
nd
Zone
N
Boiler in
Lockout?
N
Y
Y
Except as shown above, press
I
to navigate through menu.
Use
↑
,
↓
to change parameters in Adjustment Mode
Figure 11.2: Boiler Control Menu
11
Operation
(continued)