9
Light emitting diodes (
LED’s)
LED’s from left to right:
Link
LED
Ethernet cable is OK when lit
Act.
LED:
Frequent flashing means data exchange
LED
– bi-color LED
Red flashes 2 times per second
– no connection to the ACS server
Green flashes once per second
– connection to the ACS server is OK
Panel operation
The panels supplied unloaded with factory settings below in document. In this state,
the bi-color LED on the panel flashes red twice per second. To make the panel work
in access control system (ACS) you have to upload a network setting using the
"Configurator" software and USB port or use the automatic adjustment mode.
Panel goes to the
“Normal” mode after uploading the configuration.
To return to the factory settings use the command from the U-Prox software or with
the routine described in Service Maintenance section.
In the Normal mode panel processes information from U-Prox IP500 panels received
through the built-in wireless ISM band interface or via U-Prox HE and U-Prox HW
repeaters. U-Prox HE and U-Prox HW repeaters and U-Prox IC L transact through
Ethernet or Wi-Fi and local computer network.
Communicator operation
U-Prox IC L panel operates automatically. After the upload from the access control
system server the data from the permitted repeaters and U-Prox IP500 wireless
control panels processed and access event messages are sent to the access control
system server.
Panel Communicator operates in
notification
mode that means that data
transmission to the access control system server is initiated on the access event.
U-Prox IC L panel connected to the computer network with wired Ethernet.
Both
local
enterprise computer network operation (see Fg.3) and
Internet network
(see Fg.4) operation via repeaters provided. This allows the distributed systems of
any scale construction.