background image

http://u-prox.com

 

 

11

 

 

Figure 4

. Distributed network example 

It  is  highly  recommended  to  use  VPN  technology  for  computer  network 
connecting central office with sites for additional security. 

It  is  highly  recommended  to  use  routers  with  two  different  technology  Internet 
access channels fir redundancy. 

Algorithm of working in LAN 

1. 

If DHCP - obtaining IP address with the start of the access control panel 

2. 

Update  of IP status of address (announcement  and  extension  of reserved 
IP, if DHCP) 

3. 

Determine accessibility of ACS server (IP or DNS name) 

4. 

Periodic sending of test signals 

5. 

If there is, sending of events. Waiting for server commands. 
 

Algorithm of operation on the Internet (local wire net) 

1. 

If  DHCP  -  obtaining  of  IP  address  within  local  network  affiliate  at  panel 
launch 

2. 

Update  of  status  of  IP  addresses  (announcement  and  extension  of 
reserved IP, if DHCP) 

3. 

Determine  possibility  of  access  to  the  Internet  (accessibility  of  given  IP 
address of router) 

Summary of Contents for IC L

Page 1: ...1 003 Access control panel U Prox IC L Installation and programming manual...

Page 2: ...ment of external devices and panel configuration are described in Working with the device section Technical support To get warranty and technical support you can apply to authorized service centers si...

Page 3: ...tion 9 Communicator operation 9 Wireless lock system architecture 12 Wireless lock system deployment 12 How to work with the device 15 Connection 15 Mount recommendations 16 Communication 16 Wired com...

Page 4: ...E Panel can connect to a Power over Ethernet PoE switch or injector simplifying installation and eliminating the need for expensive additional wiring U Prox IC L has advanced hardware capabilities and...

Page 5: ...non 1 EU 868 0 868 6 MHz ITU Reginon 2 USA 902 5 914 5 MHz ITU Reginon 3 AUS 915 5 927 5 MHz o Guaranteed range of 20 m o U Prox HE and U Prox HW repeaters for range extention One micro USB B port for...

Page 6: ...he access control system implying control of passing through a door in one direction It consists of reader access control panel or its part door supervision devices like door contact RTE button etc an...

Page 7: ...U Prox IC L modification 1 Figure 2b U Prox IC L modification 2 Location of jumpers and connectors on control panel board and their function is shown in Fig 2 a and b 1 The Enclosure 2 Ethernet port...

Page 8: ...signment of the access control panel Contact Name Purpose 12V 12V External 12V power supply connection GND GND USB Connector Micro USB B USB Connector For network settings configuration and firmware u...

Page 9: ...in Service Maintenance section In the Normal mode panel processes information from U Prox IP500 panels received through the built in wireless ISM band interface or via U Prox HE and U Prox HW repeater...

Page 10: ...http u prox com 10 Figure 3 Mixed type Ethernet Wi Fi local network connection example...

Page 11: ...the access control panel 2 Update of IP status of address announcement and extension of reserved IP if DHCP 3 Determine accessibility of ACS server IP or DNS name 4 Periodic sending of test signals 5...

Page 12: ...ontrol panel routes data from the allowed U Prox IP500 wireless panels via U Prox HE and U Prox HW repeaters The U Prox access control system server U Prox IC L U Prox HE and U Prox HW communicate eac...

Page 13: ...ystem IP address IP or DNS name is not set a Panel sends data packages announcing access control system server about itself as a new device in the local network Despite it is broadcast announcement it...

Page 14: ...ive network equipment That s why the IP addresses of the U Prox IC L panel are to be set manually for networks with sophisticated topology b The system will warn operator after the receiving of the da...

Page 15: ...access control system eliminating panel control capture with another system Return panel to the factory settings to eliminate the panel connection to the system 3 U Prox IP500 returns to the normal op...

Page 16: ...nect the wires Communication U Prox IC L uses wired computer networ for connection to the access control system server With computer program Configurator the adjustment of following parameters provide...

Page 17: ...ta transmission speed is 100Mbit sec The Ethernet connection examples are on the Fig 9 Connector 1 Connector 2 Direct connection Connection to switch or router 1 white yellow 1 white yellow 2 yellow 2...

Page 18: ...order Software Actions 1 Define desirable adjustment mode automatic or manual Configurator through the USB 2 Adjust initial settings if manual configuration used a Server settings IP address or server...

Page 19: ...ming mode do the following 1 Do not turn off the power 2 Open enclosure 3 Connect cable to the USB and configure the device using the software Configurator Replacing the device firmware 1 De power the...

Page 20: ...http u prox com 20 Reference for device installation modification 2...

Reviews: