14
d.
Operator has to upload panel after
it’s adjustment recorded into
the DB. Panel will be connected to the certain access control
system server, eliminating panel control capture with another
system.
Return panel to the factory settings to eliminate the panel
connection to the system
e.
In the case of access control system IP address change panel
will initiate the automatic configuration routine, but the data
exchange will be possible with previously connected system only.
U-Prox IC L addresses automatic configuration for repeaters
1.
Repeater checks for DHCP mode ON (panel address 0.0.0.0) or static IP
2.
If DHCP mode is ON, the dynamic IP address obtain routine will start
3.
The panel automatic configuration mode starts if the U-Prox IC L panel IP
address (IP or DNS name) is not set:
a.
Repeater sends data packages announcing U-Prox IC L panel
about itself as a new device in the local network
Despite it is broadcast announcement it limited with one range
local network and active network equipment. That’s why the IP
addresses of the U-Prox IC L panel are to be set manually for
networks with sophisticated topology.
b.
The system will warn operator after the receiving of the data
package from the new repeater through the U-Prox IC L panel.
Than operator must add repeater to the system database (DB).
c.
Operator has to upload U-Prox IC L panel after repeater recorded
into the DB.
d.
After the U-Prox IC L panel uploaded repeater it receives the
answer from the U-Prox IC L panel. The address of the U-Prox IC
L panel recorded into the repeater and it stops to broadcast.
Panel will be connected to the certain access control system
server, eliminating panel control capture with another system.
Return panel to the factory settings to eliminate the panel
connection to the system
e.
In the case of the U-Prox IC L panel IP address change repeater
will initiate the automatic configuration routine, but the data
exchange will be possible with previously connected system only.
U-Prox IP500 automatic configuration
1.
U-Prox IP500 announces itself in the ISM band after the power-up
2.
If U-Prox IP500 does not connected to anyone U-Prox IC L the automatic
configuration mode will start: