![U-Prox IC L Installation And Programming Manual Download Page 19](http://html1.mh-extra.com/html/u-prox/ic-l/ic-l_installation-and-programming-manual_3078685019.webp)
19
Service maintenance
Return to factory settings
To Return to factory settings:
1.
De-power control panel
2.
Press and hold FUNC button
3.
Supply power to control panel
4.
Wait for 10 seconds, until LED diode lights and release FUNC button
5.
LED diode will flash 6 times that means factory settings restored
Switching to programming mode
To put access control panel in programming mode do the following:
1.
Do not turn off the power.
2.
Open enclosure
3.
Connect cable to the USB and configure the device using the software
"Configurator"
Replacing the device firmware
1.
De-power the panel
2.
Remove the top cover of panel
3.
Connect the notebook with USB cable to the panel
4.
Using special software, do the replacement of panel firmware
5.
After downloading the software to the access control panel WAIT for or 40-
50 seconds. (If readers are connected wait for 6 short beeps)
Factory settings
Communicatior
Ethernet mode enabled, DHCP enabled (no device IP set), no ACS server set