SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE •
SERVICE
USER GUIDE
u-line.com
To ensure the windings are not shorted, check the S
and R to ground.
EMU45HSC
Refrigerant
R134a
Voltage
115 VAC
Frequency
60 Hz
Run Cap
12μF/160 VAC
Start Winding
56 Ohm at 77°F
Run Winding
6.7 Ohm at 77°F
LRA
6.5 A
FLA
1.5 A
Starting Device
8EA3B3
Overload
4TM283NFBYY-53
* All resistance readings are ±10%
Compressor Specifications 1