Installation and commissioning
● Connect all plugs as labelled to the control box .
● On the
TYPICAL 574
with the control unit
P40 ED
plug
1
of the adapter cable (see blow-up)
should be inserted in socket
X2.
The motor and the "external" plug of the synchronizer
should be connected to the "motor" plug.
● On the
TYPICAL 574
with the control unit
P44 PD-L
the synchronizer plug should be inser-
ted directly in socket
X7.
● Screw the earth cable from the sewing head and the main switch to earth point
A.
● Connect earth point
A
to earth point
B
with earth cable.
● Fasten the earth cable from plug
X1
to earth point
B.
8
.04
Connecting the safety sw itch
● Connect plug
1
of safety switch
2
as
shown in Fig.
8-09.
2
When the sewing head is til-
ted back, the safety switch pre-
vents the machine starting
when the main switch is on.
1
Fig. 8 -09
8
.05
Checking the start inhibitor function
● Switch the machine on at the main switch and tilt back the sewing head.
● The error message "Error
9"
must appear on the control panel.
● If the message does not appear, check the setting of safety switch
2.
● After the sewing head has been returned to the upright position, the machine is
ready for operation again.
61-113
27