Qwik Install

 

STEP 1:

 

Add Grounding Wire Between Door and Enclosure: Remove 

plastic covers on copper studs 

on inside of door and inside of 

enclosure. Add jumper wire be-

tween 2 copper studs and use 

copper washers and nuts to se-

cure.

 

STEP 2:

 

Add wire feedthrus and 

any necessary connectors into 

the bottom connector plate. Plug any unused holes with hole plugs pro-

vided. Attach the connector plate to the bottom of the enclosure using 

self tapping screws provided.

 

STEP 3:

 

 

Install hole plug in drain hole in bottom right corner of the en-

closure.

 

STEP 4:

 

Mount any equipment to the orange backplate and secure the 

backplate in the enclosure. Equipment can also be mounted to the in-

side of door if more room is required.

 

STEP 5:

 

Insert the battery platform in the bottom of the enclosure. The 

battery platform has cutouts so wires can be routed under the battery 

as needed.

 

STEP 6:

 

Connect Bat-

tery Cable to Controller.  

Be sure to observe prop-

er connection polarity.

 

STEP 7:

  If pole mount-

ing the enclosure, as-

semble the pole mount kit to the back of the enclosure and mount the 

enclosure to a pole using the 6 hose clamps provided. The enclosure 

can also be wall mounted using the 4 holes in the back of the enclo-

sure.

 

STEP 8:

  Assemble the solar panel mount and set the correct tilt angle 

based on your Latitude.  There is a useful tool to calculate optimum an-

gle at tyconsystems.com If you will be using a fixed angle all year we 

Summary of Contents for RemotePro RPST-2424

Page 1: ...ights and power circuits Contact with power lines lights or power circuits may be fatal We rec ommend to install no closer than 20 feet to any power lines Safety For your own protection follow these safety rules Perform as many functions as possible on the ground Do not attempt to install on a rainy windy or snowy day or if there is ice or snow accumulation at the install site or if the site is we...

Page 2: ...backplate in the enclosure Equipment can also be mounted to the in side of door if more room is required STEP 5 Insert the battery platform in the bottom of the enclosure The battery platform has cutouts so wires can be routed under the battery as needed STEP 6 Connect Bat tery Cable to Controller Be sure to observe prop er connection polarity STEP 7 If pole mount ing the enclosure as semble the p...

Page 3: ... for winter sun Mount the solar panel mount to the pole using hose clamps provided Be sure to mount high enough so the door of the enclosure clears the solar panel mount when opened You can also mount the pan el to a wall using lag bolts ...

Page 4: ...t the Battery cables to the Battery Be sure to observe polarity Black wire connects to battery negative terminal and BAT terminal on the controller When a fully charged battery is connected the Green LOA LED should light on controller STEP 12 Route the solar panel cable out thru one of the feedthrus and install to the solar panel wire junction box Be sure to connect in the proper polarity red wire...

Page 5: ...ources tools We rec ommend using a fixed tilt and setting to optimize for winter sun The panel should face South if you are in the Northern Hemisphere and face North if you are in the Southern Hemisphere Some typical winter tilt angles are as follows 6 BATTERY OVERDISCHARGE We highly recommend hooking all equipment loads to the controller voltage output This output will discon nect the load if the...

Page 6: ...tice Continuous Power Rating 30W Reserve Power 30W Load 17 hours Solar Panel Capacity 24V 120W Battery Voltage DC 24V Battery Capacity 51Ah Battery Type Valve Regulated Sealed Lead Acid GEL Battery Life 5 Years Controller Type PWM 12 24V 8A Max Solar Panel Size 120W Overcharge Protection 28 6V Over discharge protection 20V Over discharge recovery voltage 22V Controller Self Consumption 0 5W Enclos...

Page 7: ...oducts are supplied with a limited 36 month warran ty which covers material and workmanship defects This warranty does not cover the following Parts requiring replacement due to improper installation misuse poor site conditions faulty power etc Lightning or weather damage Physical damage to the external internal parts Products that have been opened altered or defaced Water damage for units that we...

Page 8: ...8 8000020 Rev 4 RPST2424 RemotePro Qwik Install Guide ...

Reviews: