98
Appendix A: Event Codes
The following tables contain Contact ID and Automatic SIA format reporting codes. See Programming Sections [308] for event reporting codes.
Contact ID
Each of the digits indicate specific information about the signal. For example, if zone 1 is an entry/exit point, the event code contains [34]. The
central station would receive the following:
*BURG - ENTRY/EXIT - 1 where the “1” indicates which zone went into alarm.
See Table A-1 "Contact ID Event Codes" for code definitions.
SIA Format - Level 2 (Hard Coded)
The SIA communication format used in this product follows the level 2 specifications of the SIA Digital Communication Standard - October
1997. This format sends the account code along with its data transmission. The transmission appears similar to the following at the receiver:
N ri1
BA 01
N
= New
Event
ri1
= Partition /Area Identifier
BA
= Burglary
Alarm
01
= Zone
1
A system event uses the Area Identifier ri00.
Contact ID Zone Alarm/Restore Event Codes
Section #
Definition
Dialer
Direction*
Automatic
Contact ID
Codes
SIA Auto
Rep Codes**
Zone Events
[307]
Zone alarms
A/R
See tables on page 103 for details
[307]
Zone restores
A/R
[307]
Zone tamper/restore
MA/R
383-ZZZ
TA-ZZZ/ TR-ZZZZ
[307]
Zone fault/restore
MA/R
38A-ZZZ
UT-ZZZZ/UJ-ZZZZ
Tamper Events
[308]-[101] Keypad 1 tamper/restore alarm
T/R
(3)83-601
TA-0601/TR-0601
[308]-[101] Keypad 2 tamper/restore alarm
T/R
(3)83-602
TA-0602/TR-0602
[308]-[101] Keypad 3 tamper/restore alarm
T/R
(3)83-603
TA-0603/TR-0603
[308]-[101] Keypad 4 tamper/restore alarm
T/R
(3)83-604
TA-0604/TR-0604
[308]-[101] Keypad 5 tamper/restore alarm
T/R
(3)83-605
TA-0605/TR-0605
[308]-[101] Keypad 6 tamper/restore alarm
T/R
(3)83-606
TA-0606/TR-0606
[308]-[101] Keypad 7 tamper/restore alarm
T/R
(3)83-607
TA-0607/TR-0607
[308]-[101] Keypad 8 tamper/restore alarm
T/R
(3)83-608
TA-0608/TR-0608
[308]-[101] Keypad 9 tamper/restore alarm
T/R
(3)83-609
TA-0609/TR-0609
[308]-[101] Keypad 10 tamper/restore alarm
T/R
(3)83-610
TA-0610/TR-0610
[308]-[101] Keypad 11 tamper/restore alarm
T/R
(3)83-611
TA-0611/TR-0611
[308]-[101] Keypad 12 tamper/restore alarm
T/R
(3)83-612
TA-0612/TR-0612
[308]-[101] Keypad 13 tamper/restore alarm
T/R
(3)83-613
TA-0613/TR-0613
[308]-[101] Keypad 14 tamper/restore alarm
T/R
(3)83-614
TA-0614/TR-0614
[308]-[101] Keypad 15 tamper/restore alarm
T/R
(3)83-615
TA-0615/TR-0615
[308]-[101] Keypad 16 tamper/restore alarm
T/R
(3)83-616
TA-0616/TR-0616
[308]-[101] Siren 1 tamper/restore alarm
T/R
(3)83-801
TA-0801/TR-0801
[308]-[101] Siren 2 tamper/restore alarm
T/R
(3)83-802
TA-0802/TR-0802
[308]-[101] Siren 3 tamper/restore alarm
T/R
(3)83-803
TA-0803/TR-0803
[308]-[101] Siren 4 tamper/restore alarm
T/R
(3)83-804
TA-0804/TR-0804
[308]-[101] Siren 5 tamper/restore alarm
T/R
(3)83-805
TA-0805/TR-0805
[308]-[101] Siren 6 tamper/restore alarm
T/R
(3)83-806
TA-0806/TR-0806
[308]-[101] Siren 7 tamper/restore alarm
T/R
(3)83-807
TA-0807/TR-0807
[308]-[101] Siren 8 tamper/restore alarm
T/R
(3)83-808
TA-0808/TR-0808
[308]-[101] Siren 9 tamper/restore alarm
T/R
(3)83-809
TA-0809/TR-0809
[308]-[101] Siren 10 tamper/restore alarm
T/R
(3)83-810
TA-0810/TR-0810
[308]-[101] Siren 11 tamper/restore alarm
T/R
(3)83-811
TA-0811/TR-0811
[308]-[101] Siren 12 tamper/restore alarm
T/R
(3)83-812
TA-0812/TR-0812
[308]-[101] Siren 13 tamper/restore alarm
T/R
(3)83-813
TA-0813/TR-0813
firealarmresources.com