S e c t i o n 5 : P r o g r a m m i n g
44
[001] Miscellaneous Alarm 1
The reporting codes in this section are sent to the Alarm & Restore
call direction group.
1 – Duress Alarm
Sent when a duress code is used to perform any function on the sys-
tem.
2 – Opening After Alarm
Sent during disarming if an alarm occurred during the previous
armed period.
3 – Recent Closing Alarm
Sent if an alarm occurs within 2 minutes of the exit time expiration
(for the first alarm only). Zone alarm transmission delays do not
effect this reporting code.
4/5 – Zone Expander Supervisory Alarm/ Restore
Sent when the system loses communication with the following mod-
ules:
•
Zone Expander Module
•
Keypad with an on-board I/O configured as a zone
This reporting code is independent of the general system supervisory
code sent to the maintenance call direction group.
6 – Burglary Verified
When using Cross Zoning, this reporting code is sent when two
crossed zones go into alarm during the cross zone timer.
When using Police Code, this reporting code is sent when any two
zones go into alarm. In both cases, only one reporting code is sent
during each armed to armed period. Arming the system resets the
zone alarm count for police code.
7 – Burglary Not Verified
When using Cross Zoning, this reporting code is sent if the cross
zone timer is initiated by the first cross zone alarm, but is not verified
by a second alarm before the timer expires.
8 – Alarm Cancel
Sent when a valid access code is entered during the communications
cancel window. The central station acknowledges cancellation by
providing a keypad ringback.
NOTE:
[011] Priority Alarms 1
The reporting codes in this section are sent to the Alarm & Restore
call direction group and apply to all system keypads.
1/2 – Keypad Fire Alarm-[F] Key Alarm/Restore
Sent when [F] Key alarms/restores occur.
3/4 – Keypad Medical Alarm-[M] Key Alarm/Restore
Sent when [M] Key alarms/restores occur. The keypad beeps 10
times when the medical alarm is successfully communicated to the
alarm monitoring station.
5/6 – Keypad Panic Alarm-[P] Key Alarm/Restore
Sent when [P] Key alarms/restores occur.
7/8 – Auxiliary Input Alarm/ Restore
Sent when an alarm condition occurs/ is restored on PGM 2 (if con-
figured as an input).
[021] Fire Alarms 1
3/4 – PGM 2 2-Wire Alarm/Restore
When PGM 2 is programmed as a 2-wire smoke alarm, this reporting
code is sent when an alarm condition is detected and when it is
restored.
[101] Tamper Events
3/4 – Module Tamper/Restore
This reporting code is transmitted when a system module enters a
tamper alarm state and uses the System Tamper Alarm and Tamper
Restore call direction.
5 – Keypad Lockout
Sent when a number of invalid access codes have been entered at a
system keypad
This reporting code is sent to the system Tamper Alarm & Tamper
Restore call direction group.
7 – Remote Lockout
Sent when a number of invalid access codes have been entered
through DLS or Integration. This reporting code is sent to the system
Tamper Alarm & Tamper Restore call direction group.
[201] Open/Close Events 1
1/2 – User Closing/Opening
This reporting code is transmitted when a user arms/disarms a parti-
tion and uses the Opening and Closing call direction.
5/6 – Special Closing/Opening
This reporting code is transmitted when a partition is closed/opened
using a keyswitch zone, downloading, quick arm ([*][0]), or Stay or
Away function keys without an access code. The Opening and Clos-
ing call direction group is used for this reporting code.
[202] Open/Close Events 2
1 – Automatic Closing
This reporting code is transmitted when a partition is automatically
armed or schedule armed and uses the Opening call direction group.
3 – Auto Arm Cancellation/Postpone
This reporting code is transmitted when the automatic arm sequence
is canceled during a pre-alert and uses the Opening and Closing call
direction group.
[211] Miscellaneous Open/Close Events
1/2 – Late to Close/Open
This reporting code is transmitted when a partition is not disarmed
before the automatic disarm time, when the late to open option,
([*][6], option 9) is enabled. The Opening and Closing call direction
group is used for this reporting code.
5 – Exit Fault
This reporting code is transmitted when an exit error occurs and entry
delay expires before the system is disarmed. The Alarms and
Restores call direction group is used for this reporting code.
If the delay zone that caused the exit error has cross zoning enabled,
the exit fault and zone alarm transmits if a second zone is not tripped.
The local alarm sequence follows cross zoning rules. The exit error is
transmitted with the zone alarm that caused the fault, even if that
zone has transmission delay enabled.
[221] Bypass Events
1/2 – Automatic Zone Bypass/Unbypass
This reporting code is transmitted when a zone is automatically
bypassed/unbypassed and uses the Opening and Closing call direc-
tion group.
03 – Partial Closing
This reporting code is transmitted if zones are manually bypassed at
the time of arming or force armed by automatic arming. The Opening
and Closing call direction group is used for this reporting code.
Automatic bypasses caused by stay arming do not cause transmission
of this code.