1 0
5.1.2
When all adapters are installed slide them to the left side of the
patch panel, measure the length of the Anti Movement Strip and cut
the AMS to length (distance of the opening minus 6 slots).
5.1.3
Install the anti movement strip (AMS) on both the slot sides of
the patch panel.
5.1.4
Mount the pigtail connectors in the adapters and route the
pigtails to the splicing trays.
4.3.7
Pull gently on the fibers in the tray and make sure that the
fibers are well contained in FAS block and wraparound groove plate.
4.3.8
Store the fibers temporarily on a tray.
5
Pigtail installation
5.1
Installation of pigtails with connectors
5.1.1
Connector adapters have to be installed in the patch panel.
Push the adapter from the top in the patch panel and slide it in position.