Page 2: ...under the copyright laws of the United States CREDITS MASTR and EDACS are registered trademarks and ProGrammer is a trademark of M A COM Inc All other brand and product names are trademarks registered trademarks or service marks of their respective holders NOTICE Repairs to this equipment should be made only by an authorized service technician or facility designated by the supplier Any repairs alt...

Page 3: ...arth Ground 10 3 4 5 CAN Port 10 3 4 6 Phone Line Connection Optional 10 3 4 7 Computer Connection 10 3 4 8 LAN 10 3 4 9 Serial A 10 3 4 10 Serial B 11 3 4 11 External I O 11 4 CONTROL STATION OPERATION 12 4 1 POWERING UP THE STATION 12 4 2 GENERAL OPERATION 12 4 2 1 Setting Up And Using The Control Station Transceiver 12 4 2 2 To Receive a Call Local Only Control Stations 12 4 2 3 To Make Transmi...

Page 4: ... of Remote and Intercom Switch Positions 16 FIGURES Figure 2 1 CT 013892 001 Local Control Station with Scan Head Front View 6 Figure 2 2 CT 013892 002 Local Remote Control Station with System Head Front View 6 Figure 3 1 Front Panel Features Local Control Station 7 Figure 3 2 Front Panel Features Remote Control Station 9 Figure 3 3 Rear Panel Features Local and Remote Stations 11 ...

Page 5: ...hered to could result in personal injury Do not proceed beyond a WARNING symbol until the conditions identified are fully understood or met CAUTION The CAUTION symbol calls attention to an operating procedure practice or the like which if not performed correctly or adhered to could result in a risk of danger damage to the equipment or severely degrade the equipment performance The NOTE symbol call...

Page 6: ...ations with the local operation of the Desktop Station The Desktop Station is available in the following three models Desktop Station configuration with only local controls Desktop Station configuration with local and remote control capability Remote mount configuration with remote control capability Local Control Desktop Station model CT 013892 001 shown in Figure 2 1 is designed to provide local...

Page 7: ...al band 700 800 MHz transceiver capable of EDACS Conventional P25 and OpenSky modes of operation Both transceivers include the CH721 control head 3 1 2 1 Transceiver ON OFF Volume Control Local Control Stations rely on the transceiver s ON OFF Volume control for volume level setting Refer to Section 3 2 4 when setting the volume on remote control stations 3 1 2 2 Local Microphone The transceiver s...

Page 8: ...hone audio if the REMOTE switch is set to the ON position ON Down position This position places the Control Station operation in the INTERCOM mode Transmissions made from the Local Station Microphone will NOT key the transceiver Local Station Microphone audio will be heard only by Remote Controllers and transmissions made by Remote Controllers will only be heard over the Local Speaker Remote Contr...

Page 9: ...Station share similar rear panel features The following sub sections provide a brief description of the available rear panel features 3 4 1 AC Power Switch Cord Fuse Assembly The AC Power Switch Cord Fuse assembly is located on the left side of the rear panel when facing the rear panel As indicated it serves as the main Control Station ON OFF switch AC cord receptacle and houses the fuses for the ...

Page 10: ... similar to standard serial ports and supports full duplex connectivity to optional M A COM devices However unlike standard serial ports multiple CAN devices may share a common CAN bus A CAN bus is limited to a maximum distance of 250 ft between the two furthest devices connected to the CAN bus The Control Station can be connected anywhere along the bus A fiber optic CAN bus extender may be used w...

Page 11: ...3 4 11 External I O The External I O connector is a DB 25 female connection This port provides access to local controlling features of the transceiver such as PTT TX audio RX audio etc Foot switches and other local external customer devices may be connected to the Control Station using this connector Figure 3 3 Rear Panel Features Local and Remote Stations ...

Page 12: ...Control Station is now ready to receive messages from other radios in the system 2 When the first call is received it may be necessary to adjust the VOLUME control to the desired listening level Use the transceiver s VOLUME control to set the volume level 4 2 3 To Make Transmit a Call Local Only Control Stations 1 If more than one channel is available select the proper channel using the radio s Sy...

Page 13: ...the PTT switch as soon as the message is completed and listen for an answer to the call 4 3 REMOTE CONTROL OPERATION Control Stations equipped with Intercom and Remote switches may be remotely controlled The Intercom and Remote switches determine when remote controllers connected to the Control Station may send and receive messages via the Control Station 4 3 1 Enabling Remote Control Perform the ...

Page 14: ...l Station Microphone or a remote controller will be transmitted over the air Only intercom communications is possible 4 4 2 Momentary Intercom Operation The M position on the Intercom switch is spring loaded momentary and returns the switch to the OFF position when released This switch position allows the Control Station s local operator to make an intercom call without leaving the Control Station...

Page 15: ...TATION MANUAL NUMBER CS 7000 Installation Manual MM 014714 001 M5300 Transceiver Operator s Manual MM 012125 001 M5300 Transceiver Quick Guide when using OpenSky Systems MM 012997 001 M5300 Transceiver Quick Guide when using P25 EDACS or Conventional Systems MM 013232 001 M7300 Transceiver Operator s Manual MM 014718 001 M7300 Transceiver Quick Guide when using OpenSky Systems MM 014368 001 M7300 ...

Page 16: ...ressed 2 Microphone audio from Remote Controller is heard at the Control Station s speaker Receive Mode No PTTs Pressed N A The Control Station s receiver audio is heard at its speaker and Remote Controller s speakers 1 PTT on Control Station Microphone Pressed 1 Audio from Control Station s microphone is heard at Remote Controller s speaker and transmitted over the air Intercom Mode Selected on t...

Page 17: ...e Labor to perform warranty service will be provided at no charge during the warranty period only for the Equipment covered under Paragraph B 3 and B 4 To be eligible for no charge labor service must be performed at a M A COM factory by an Authorized Service Center ASC or other Servicer approved for these purposes either at its place of business during normal business hours for mobile or personal ...