Menu Contents
◦
RANGE ERROR
- Used to display the values of Y MAX, Y MIN, C MAX, C MIN, Y PICTURE BLINK, and C PICTURE BLINK
on the screen.
- Selected values in Y MAX, Y MIN, C MAX, C MIN are indicated in WAVEFORM/VECTOR or Y/Cb/Cr.
- If Y PICTURE BLINK or C PICTURE BLINK is enabled, the section of image that exceeds the selected
values of Y MAX, Y MIN, C MAX and C MIN blinks.
* In the case of RGB input, Range Error is not supported.
◦
Y MAX
- This item sets the maximum luminance level.
- Available values are between 0 ~ 127. Exceeded selection displays on the top portion of the
waveform or display.
-In the case of RGB input, Range Error is not supported.
◦
Y MIN
- This item sets the minimum luminance level.
- Available values are between 0 ~ 127. Exceeded selection displays on the top portion of the
waveform or display.
◦
C MAX
- This item sets the maximum chroma level.
- Available values are between 0 ~ 127. Exceeded selection displays on the top portion of the
waveform or display.
◦
C MIN
- This item sets the minimum chroma level.
- Available values are between 0 ~ 127. Exceeded selection displays on the top portion of the
waveform or display.
◦
Y PICTURE BLINK
- This item sets selections of image that exceeds Y MAX and Y MIN to blink.
◦
C PICTURE BLINK
- This item sets selections of image that exceeds C MAX and C MIN to blink.
Below is the description for each function of the AUDIO menu.
◦
LEVEL METER SELECT
- Controls the audio level meters.
- Available modes are OFF, G1+G2, G2+G3, G3+G4, G1+G3, G1+G4,G2+G4 and 16CH.
- If Main Menu window activates, the level meter displays semi-transparent even if [LEVEL METER
SIZE] menu is set to opaque. It returns to normal when the Main Menu window is deactivated.
◦
LEVEL METER DISPLAY
- Controls display method of audio level meter.
- Available modes are PAIR and GROUP.
◦
LEVEL METER REFERENCE
- This item sets audio level default.
- Available values are -18dB and -20dB.
- Audio within selected value is displayed in green and exceeded audio level is displayed in yellow.
Audio exceeding -4dB is displayed in red.
◦
LEVEL METER DECAY TIME
- This item sets the reduction time of the maximum indication of audio signals.
-
Available values are between MIN (0) ~ MAX (30). Larger values indicate a longer time for it to display.
◦
LEVEL METER SIZE
- Controls the size of the audio level meters.
- Available modes are SMALL, SMALL TRANS., NORMAL, NORMAL TRANS, LARGE and LARGE TRANS.
- In SMALL, NORMAL and LARGE modes, the Level Meter appears opaque.
- In SMALL TRANS. NORMAL TRANS and LARGE TRANS Modes, the Level Meter appears semi-
transparent.
SDI A LVM-420A 1080/60i
LEVEL METER SELECT OFF
LEVEL METER DISPLAY PAIR
LEVEL METER REFERENCE -20dB
LEVEL METER DECAY TIME MIN
LEVEL METER SIZE SMALL
LEVEL METER POSITION HOR.
VOLUME MIN
Em. AUDIO LEFT OFF
Em. AUDIO RIGHT OFF
[8] AUDIO
Menu Contents