19 

0x33

exit counter off; 

0x22 

0x01

 

0x30-0x31

 

Counter Reset:     

0x30

entry counter reset

 

0x31

exit counter reset

0x24

 

0x01

 

0x30-0x31

 

Setting 

tripod 

turnstile 

auto-drop  &  raise  (only 

applicable  to  fully  automatic 

tripod turnstiles ): 

0x30

auto-drop; 

0x31

auto-raise

0x28

 

0x01 

0x30-0x31

 

Reading 

entry 

exit 

counting: 

0x30: reading entry counting; 

0x31: reading exit counting; 

After receiving the command, 

the control board will send the 

corresponding  counting  (see 

the  sending  command  format 

table) 

0x42 

0x01 

0x31-0x37 

Setting  the  door  opening  & 

closing speed ranking (1-7) 

0x31-0x37:  ASCII  code  of 

1-7  (inapplicable  to  tripod

turnstiles)

0x81 

0x01 

0x31-0x35 

Setting  the  IR  sensors’ 

sensitivity ranking (1-5) 

0x31-0x35:  ASCII  code  of 

1-5

(inapplicable 

to 

tripod 

turnstiles) 

0x82 

0x02 

0x31- 

0x32 

0x31- 
0x35 

Control  LED  panel,  after 

receiving 

this 

command, 

control  panel  will  control 

LED  panel  to  display,  and 

then  return  to  the  feedback 

command.   

The  first  word  refers  to  LED 

panel address: 

0x31: LED panel 1 

0x32: LED panel 2 

The second word refers to the 

image  which  LED  panel 

displays: 

0x31: prohibition 

Summary of Contents for TPW-321ASP

Page 1: ...OPERATING MANUAL AUTOMATIC SWING GATE TPW 321ASP...

Page 2: ...4 3 SYSTEM COMPOSITION 4 5 EQUIPMENT ASSEMBLY AND INSTALLATION 4 5 1 EQUIPMENT INSTALLATION 4 5 2 EQUIPMENT FUNCTIONAL TEST 6 5 3 3 FAR END CONTROL 6 6 OPERATION INSTRUCTION OF THE EQUIPMENT 7 7 REGU...

Page 3: ...the system It is recommended that the user read carefully the operation manual prior to application of the equipment otherwise your right may be infringed due to an improper application of the equipme...

Page 4: ...ctro mechanism mounted within the top section of the Automatic Swing Gate and accessible by open the Top Cover Purely mechanical control is also possible 8 It is provided with multiple operation modes...

Page 5: ...des there are also different types and specifications depending on different read write equipment installed 1200 Figure 1 4 Basic Operation Principle 4 1 Basic Operation Principle When card in card ou...

Page 6: ...ay flow limit 2 One way reading card the other way barring 4 3 System Composition The product can either be used independently to form a passage or be combined into multiple passages of intelligent ma...

Page 7: ...undation Drawing for Ground Installation 5 Pull the cable of the heavy current light current through the 3 4 PVC tubes respectively and bury them into the relevant position with cement 6 Move the equi...

Page 8: ...for unlocking After the pre set time the main controller controls the motor drives the barrier rotate to the limit position and lock automatically the counter will automatically increase 1 at the pass...

Page 9: ...a green lamp Otherwise the normal operation of equipment may be affected 6 3 It is forbidden to sit or press with force on the barrier rod when the equipment is not in use otherwise the turnstile may...

Page 10: ...ection grounding of the system to ensure a reliable connection 4 It is required to check regularly the connectors and line connection points to ensure a reliable connection 8 Common Failures and the R...

Page 11: ...nd sound alarm if passengers get into the gate area without sign in sign out NC mode normal close gate stay in close state gate will open if passenger sign in sign out successfully gate will return to...

Page 12: ...oor closing time setting the max time for each passenger entering the passage The value effective range is 1 60 unit is second Default 5 4 Entry counter reset clear entry counting value 5 Exit counter...

Page 13: ...11 Attached Figure 4...

Page 14: ...12 2 The instructions of turnstile control panel Turnstile control panel instructions shown as Attached Figure 4 Attached Figure 4...

Page 15: ...panel The common wirings for customer 1 OPEN_R Entrance open signal access dry contact signal 2 OPEN_L Exit open signal access dry contact signal 3 EMO Emergency signal access dry contact signal Conne...

Page 16: ...ertime waiting time is 2 seconds The control board of turnstiles will send related parameters after received feedback signal Every parameter sent by main board needs the feedback signal address if you...

Page 17: ...l board successfully corresponding commands can be sent to the control board to set the parameters The control board will send success return signal 0x02 0x44 0x00 0x04 to PC if the setting is success...

Page 18: ...c tripod turnstiles For detailed command formats please refer to 3 Control Board Receiving Command Below is the flow Chart 2 Control Board Sending Command Control Board Sending Command Format Command...

Page 19: ...tatus the second word shows exit status 0x30 Controlled Mode 0x31 Free Passing Mode 0x32 Forbidden Passing 0x33 Barrier free passing after swiping card 0x18 0x03 0x30 0x39 0x30 0x39 0x30 0x39 Door clo...

Page 20: ...x33 Setting working mode of entry exit the first word shows setting entry working mode the second word shows setting exit working mode 0x30 Controlled Mode 0x31 Free Passing Mode 0x32 Forbidden Passin...

Page 21: ...counting see the sending command format table 0x42 0x01 0x31 0x37 Setting the door opening closing speed ranking 1 7 0x31 0x37 ASCII code of 1 7 inapplicable to tripod turnstiles 0x81 0x01 0x31 0x35...

Page 22: ...is command the control panel will set the display image of LED panel on both sides according to the command contents and then return to the feedback command The first word refers to LED panel address...

Reviews:

Related manuals for TPW-321ASP