16
The control board is now available for PC to set the following parameters:
1) Turnstile Working Mode
2) Working Mode of Entry & Exit
3) Door Closing Delay
4) Door Opening & Closing Speed (inapplicable to tripod turnstiles)
5) Entry & Exit Counter Reset
6) Entry & Exit Counter Switch
7) IR Sensors’ Sensitivity (inapplicable to tripod turnstiles)
8) Auto-Drop & Raise (only applicable to fully automatic tripod turnstiles)
For detailed command formats, please refer to 3. Control Board Receiving Command.
Below is the flow Chart:
2. Control Board Sending Command
Control Board Sending Command Format
Command
Start Symbol
Command
Type
Command
Length
Command Content
Command
End
Symbol
Command
Descriptions
0xFF
0x00
NULL
Connection success
return signal
0x44
0x00
NULL
Receiving command
success return signal
0xF4
0x00
NULL
Receiving command
failure return signal
0xF1
Command
Content
Length
Equipment Model ASCII Code
Equipment
model
name
0xF2
Software Version ASCII Code
Software
Version