![TurnOnGreen FSP 600 User'S Manual & Installation Instructions Download Page 21](http://html1.mh-extra.com/html/turnongreen/fsp-600/fsp-600_users-manual-and-installation-instructions_1182203021.webp)
3.5 Recommended Tools for Installation and
Inspection
3�5�1 Recommended Tools for Installation
Type
Description
Philips Screwdriver
No. 2 and 3
Shifting Wrench
Socket Screwdriver
No. 8, 10, 17 and 19
Electrical Tape
Black / 15mm (0.6”) Width
AC Input Cable
53.5mm² (106 kcmil) at least Cable x 5 (L1, L2, L3,
N, PE)recommend 600V, 90
°
C, XLPE power cable
Ring Terminal
1. Ring Terminal for L1, L2, L3, N(Inner Diameter:
10.5mm (0.41”), Outer Diameter: 22mm (0.87”))
2. Ring Terminal for PE (Inner Diameter: 6.4mm
(0.25”), Outer Diameter: 22mm (0.87”))
Crimping Pliers for Ring
Terminal
Wire Stripper
Wire Cutters
Crane/ Forklift
>235 kg (518 lbs)
3�5�2 Recommended Tools for Inspection & Commissioning
Type
Description
EV or EV Simulator
Meet CHAdeMO/CCS Standard
Multiple Meter
1000V
Current Probe
200Amp
RFID Authorized Card
RFID No Valid Card
Door Key
Needle-Nose Plier
Laptop or PC & CAT6 cable
For Charger Configuration
Wi-Fi /4G signal quality checker
Recommended
18