Technical Data

No. of channels

4

Connection technology of outputs

M12, 5-pin

Output type

PNP

Type of output diagnostics

Channel diagnostics

Summary of Contents for TN-UHF LNX Series

Page 1: ...Your Global Automation Partner Instructions for Use TN UHF LNX UHF Read Write Head ...

Page 2: ...2 Hans Turck GmbH Co KG T 49 208 4952 0 F 49 208 4952 264 more turck com www turck com ...

Page 3: ...15 6 3 Connecting digital sensors and actuators 16 6 4 Connecting external antennas 17 7 Commissioning 18 7 1 Setting read write head parameters with the DTM 18 7 1 1 Connecting the device with the PC 19 7 1 2 Starting the extended read write head parameter setting 22 7 1 3 DTM main menu Overview 23 7 1 4 Choosing the access level 24 7 1 5 Setting multiplex operation 24 7 1 6 Setting antenna power...

Page 4: ...ions 58 7 6 1 LEDs Overview 58 7 6 2 Setting LED functions via a script 58 7 6 3 Programming LED functions with Python 3 59 7 6 4 Programming LED functions with Node js 60 7 6 5 Programming LED functions with C or C 61 7 7 Creating a C application 62 7 8 Starting the application automatically Autostart 63 7 8 1 Autostart Creating the configuration file unit file 63 7 8 2 Example Using the unit fil...

Page 5: ...ided CAUTION CAUTION indicates a dangerous situation of medium risk which may result in minor or moderate injury if not avoided NOTICE NOTICE indicates a situation which may lead to property damage if not avoided NOTE NOTE indicates tips recommendations and useful information on specific actions and facts The notes simplify your work and help you to avoid additional work u CALL TO ACTION This symb...

Page 6: ...HF Q300 CHN LNX 920 5 924 5 MHz China TN UHF Q180L300 CHN LNX 920 5 924 5 MHz China TN UHF Q300 KOR LNX 917 920 8 MHz Korea TN UHF Q180L300 KOR LNX 917 920 8 MHz Korea TN UHF Q300 BRA LNX 915 928 MHz Brazil TN UHF Q180L300 BRA LNX 915 928 MHz Brazil TN UHF Q300 RUS LNX 866 868 MHz Russia TN UHF Q180L300 RUS LNX 866 868 MHz Russia TN UHF Q300 AUS LNX 920 926 MHz Australia TN UHF Q180L300 AUS LNX 92...

Page 7: ...n The Turck product database contains software tools for programming configuration or commissioning data sheets and CAD files in numerous export formats You can access the product database at the following address www turck de products For further inquiries in Germany contact the Sales and Service Team on n Sales 49 208 4952 380 n Technology 49 208 4952 390 Outside Germany please contact your loca...

Page 8: ...z TN UHF NA LNX 902 928 MHz TN UHF CHN LNX 920 5 924 5 MHz TN UHF KOR LNX 917 920 8 MHz TN UHF BRA LNX 915 928 MHz TN UHF RUS LNX 866 868 MHz TN UHF AUS LNX 920 926 MHz These devices may only be started up under the following conditions n The particular frequency range is permissible for the use of UHF RFID n The operating frequency range of the devices is compliant with the permissible UHF RFID r...

Page 9: ...y be used in accordance with applicable national and international regu lations standards and laws n Any extended stay within the area of radiation of the UHF read write heads may be harmful to health Observe minimum distances from the actively radiating surface of the UHF read write head Region Max permissible total radiant output power Safety distance Europe Russia China 2 W ERP according to ETS...

Page 10: ...0 or for con necting external antennas Q180 Both device variants are suitable for connecting up to four external passive UHF RFID antennas The terminals for the Ethernet and for digital I Os are M12 sockets The device has an M12 plug connector for connecting the power supply Terminals are also provided for up to four external antennas 4 1 Device overview 180 300 61 7 100 100 46 125 219 126 Ø 6 5 F...

Page 11: ...power A read write head contains a transmitter and a receiver an interface to the interface and a coupling element coil and dipole antenna for communicating with the tag Electromagnetic wave propagation is used for the transmission between read write head and tag on devices for the UHF range IC Read write head Data carrier UHF electromagnetic wave Fig 3 Operating principle of UHF RFID The antenna ...

Page 12: ...The devices can be fully tested configured and parameterized from a PC using the specified software tools The Linux operating system enables the device functions to be programmed with C C NodeJS or Python It is also possible to integrate middleware functions on the device Sensors and actuators can be connected to the configurable digital channels Up to four 3 wire PNP sensors or two PNP DC actuato...

Page 13: ...nd vertic ally The max length of the screws is 8 mm plus the thickness of the VESA bracket The devices can be mounted in any position Fasten the device with four M4 screws to a bracket in accordance with VESA 100 x 100 100 3 94 100 3 94 219 8 62 126 4 96 Ø 6 5 0 26 4 M4 46 1 1 82 100 3 94 100 3 94 126 4 96 Ø 6 5 0 26 4 M4 46 1 1 82 219 8 62 Fig 4 Rear view TN UHF Q180 Fig 5 Rear view TN UHF Q300 ...

Page 14: ... with a 4 pin M12 female connector for connecting the device to an Eth ernet system Fig 6 M12 Ethernet connector Connect the device to Ethernet as per the following pin layout max tightening torque 0 8 Nm v 4 1 3 2 ETH1 PoE 1 TX 2 RX 3 TX 4 RX flange FE Fig 7 Pin layout of the Ethernet connections NOTE With PoE transfer the power supply via PoE Mode A with 4 wire cables ...

Page 15: ...tors for connecting the power supply Fig 8 M12 plug connector for connecting the power supply Connect the device to the power supply as per the following pin layout max tightening torque 0 8 Nm 1 V1 2 TX RX 3 GND 4 TX RX 5 PE 2 1 5 4 3 3 2 1 5 4 24 VDC COM Fig 9 Pin layout of the power supply terminals ...

Page 16: ...ors and actuators Connect sensors and actuators to the device as per the following pin layout max tight ening torque 0 8 Nm 4 1 3 2 5 v 1 Vaux2 2 Signal In Out 3 GND V2 4 Signal 5 FE DXP0 DXP3 5 FE 4 BK 1 BN 3 BU 3 BU 2 WH v DXP0 DXP3 Sensor or Actuator Sensor or Actuator Fig 11 Connections for digital sensors and ac tuators Pin layout Fig 12 Connections for digital sensors and ac tuators Wiring d...

Page 17: ... is provided with four RP TNC sockets for connecting up to four external antennas The input impedance is 50 Ω Fig 13 RP TNC sockets for connecting external antennas Connect external antennas with an RP TNC antenna cable to the device max tightening torque 0 8 Nm ...

Page 18: ...ware components can be downloaded via the Turck Software Man ager The Turck Software Manager is available free of charge from www turck com NOTE The parameterization function is only available in English All parameters are written in the DTM The individual read write heads are available in different variants When a connection is made to a connected read write head the DTM automatically detects the...

Page 19: ...V01 00 2019 04 19 7 1 1 Connecting the device with the PC Launch PACTware Right click Host PC in the project tree Click Add device Add RS485 RFID Confirm selection with OK Fig 15 Selecting RS485 RFID ...

Page 20: ...Commissioning 20 Hans Turck GmbH Co KG T 49 208 4952 0 F 49 208 4952 264 more turck com www turck com Right click the Ethernet adapter Start the Topology scan Fig 16 Starting the Topology scan ...

Page 21: ...V01 00 2019 04 21 The connected devices are automatically detected and added to the project tree Fig 17 Project tree ...

Page 22: ...m www turck com 7 1 2 Starting the extended read write head parameter setting Right click the device Start the parameter setting Choose Parameterization or Online Parameterization The device must be connected to the PC for the Online Parameterization Fig 18 Starting the parameterization ...

Page 23: ...t setting n Advanced n Administrator password protected Channel wise display Toggles the view between standard display and channel wise display Load parameters from the database Loads previously stored parameters from the database e g an existing project Transfers parameters to the database Transfers the current read write head parameters to the data base of the project Compare values with databas...

Page 24: ...cation are available in the Advanced access level Access level Description Initial password Basic Basic access for configuration and commis sioning Not required Advanced Extended access e g for applications Not required Administrator Administrator access for critical security or wireless settings Required The current access level is displayed in the top right screen area of the DTM 7 1 5 Setting m...

Page 25: ...ntenna tab in the main menu At Antenna Ò Antenna multiplexing Ò Number of entries enter the number of anten nas Fig 21 Entering the number of antennas Assign antennas with functions e g internal antenna RHCP LHCP external antenna Fig 22 Example Setting multiplex operation ...

Page 26: ...4952 264 more turck com www turck com Click Accept to save the settings For all antennas used set at Antenna configuration Ò Maximal transmit time the time in which the particular antenna is to remain active and stay switched on Fig 23 Setting maximal transmit time ...

Page 27: ...ets of the components used for the cable attenuation and an tenna gain Fig 24 Power calculation Relevant variables schematic representation The power can be calculated with the following formula PERP GHW dB Pcond Setting antenna power Restrictions of radio regulations Some national regulations restrict the degree of freedom available for creating an RFID system You as the operator are responsible ...

Page 28: ...be stated in watts or in dBm The following table shows approximate values as a guide for converting between dBm and mW dBm mW dBm mW dBm mW dBm mW 1 1 25 9 8 17 50 25 316 2 1 6 10 10 18 63 26 400 3 2 11 13 19 80 27 500 4 2 5 12 16 20 100 28 630 5 3 13 20 21 125 29 800 6 4 14 25 22 160 30 1000 7 5 15 32 23 200 8 6 16 40 24 250 33 2000 The formula for calculating the exact values is dBm 10 lg P 1 mW...

Page 29: ...nternal antenna is limited to 1 W With external antennas 1 W of output power is provided at the TNC socket The power supply type is set automatically via Antenna configuration Ò Power supply to the ex ternal power supply value Set the radiated power via Antenna Configuration Ò Radiated power here 33 dBm ERP Fig 25 Setting the radiated power ...

Page 30: ...Co KG T 49 208 4952 0 F 49 208 4952 264 more turck com www turck com Refer to the data sheet of the cable used for the cable attenuation Enter the cable attenuation at Antenna cable attenuation Fig 26 DTM Entering the cable attenuation ...

Page 31: ...ata sheet of the external antenna for the antenna gain Set the unit for the antenna gain at Antenna gain unit here dBd Fig 27 Setting the unit for the antenna gain Set antenna gain at Antenna gain here 9 00 Fig 28 Setting antenna gain ...

Page 32: ...4952 264 more turck com www turck com The power at the TNC socket Pcond is calculated automatically by the DTM and displayed at Conducted power Fig 29 Display of the power at the TNC socket Click Accept to save the settings Set the power for each additional antenna ...

Page 33: ...eased by switching the polarization Polarization switching is suitable for example in single tag applica tions in particularly metallic environments The following graphics schematically illustrate the possibilities of antenna polarization ANT ANT Fig 30 Antenna polarization circular RHCP Fig 31 Antenna polarization circular LHCP ANT ANT Fig 32 Antenna polarization linear vertical Fig 33 Antenna po...

Page 34: ...ck com Switching antenna polarization Polarization switching is activated in the DTM via the multiplex settings Set at Antenna Ò Number of entries the value 2 Set at Antenna Ò 1st entry the value Antenna LHCP Set at Antenna Ò 2nd entry the value Antenna RHCP Fig 34 Switching antenna polarization ...

Page 35: ...eration without reading to the next multiplex sequence Entry Fig 35 Switching polarization automatically 7 1 8 Switching on Presence sensing mode In order to use the Continuous presence sensing mode the Presence sensing mode must be ac tivated in the read write head In Presence sensing mode the read write heads are automatic ally switched on as soon as a tag is located in the detection range Choos...

Page 36: ... the parameters for the configuration of the deBus mes sages All parameters and the settable values are written in the DTM Example Switch on RSSI transmission Switch on RSSI transmission Choose Communication Ò Message data content Ò Transponder RSSI and select the enabled option a The RSSI value is displayed with the inventory in the read data Fig 37 Switching on the RSSI transmission ...

Page 37: ... an Inventory command All para meters and the settable values are written in the DTM Example Set the tag reset The tag reset function makes it possible to set how often a tag returns a signal to the read write head with an Inventory operation The tag reset function is only useful in single tag applica tions EPC Class 1 Gen 2 Ò Inventory Ò Inventory profile 1 Transponder reset Ò Enter value here 15...

Page 38: ...a traffic on the air interface and are not suitable for multi tag applications with many tags or high passing speeds All parameters and the settable values are written in the DTM Example Setting the RSSI filter An RSSI filter makes it possible to prevent unwanted read operations All read operations with an RSSI outside of the set limit values are filtered out and not displayed At Post Read Filter ...

Page 39: ...ple All read operations below an RSSI value of 45 dBm are filtered out Fig 40 Example Setting the limit value for RSSI 7 1 12 Setting LED indication Signaling The Signaling tab enables the default settings for the USER LEDs to be edited All parameters and the settable values are written in the DTM ...

Page 40: ...tion between host or PC and read write head n Sending of user specific deBus commands n Writing of tags with a user defined number n Sending tag specific commands Requirements for the RFID test n PACTware must be installed n The DTM for UHF read write heads must be installed n The connection between the read write head and the PC must be established n A project must have been created in PACTware 7...

Page 41: ...V01 00 2019 04 41 7 2 2 Start window Overview The RFID Test window consists of the following elements n Main menu n Basic test n Tag actions n Logger Fig 42 RFID test Overview of start window ...

Page 42: ...be selected n Phase n RSSI n Socket n Time Switch mode report polling Switches between Report mode automatic read write and polling mode read write started through an explicit polling command Read read write head Calls the following information from the read write head and provides the information in the Logger window n Read write head status Read read write head version Calls the following inform...

Page 43: ...ailable in polling mode Poll all Shows all tags in the polling memory of the device in the tag list The function is only available in polling mode Delete polled tags of the read write head Clears the polling memory of the read write head CSV export of the current data Saves the tag list in CSV format Delete tag list Deletes the list of displayed tags The queried data is displayed in the tag list T...

Page 44: ...tically displayed One word is always read with the first read operation The following parameters can be set for other read operations n Memory bank TID EPC UID PC access password or kill password n Start word n Number of words The read data is displayed in the Data area Write tag Starts the write operation The chip type is automatically displayed The following para meters can be set for the write ...

Page 45: ... to display tag in the tag list Basic test window Select tag from the tag list Fig 46 Selecting a tag Tag actions window Enter required values and confirm entry with ENTER Switch trigger off to activate the buttons Fig 47 Entering the data Execute the required function by clicking the appropriate button here Read Fig 48 Execute tag action example read ...

Page 46: ...Successful access is displayed via the status message at the bottom of the window Fig 49 Example Successful read operation 7 2 6 RFID test Logger window The Logger window displays read write information and error messages The list can be cleared via the Delete button Fig 50 Messages in the Logger window ...

Page 47: ...ad is displayed for each channel in the HF dia gnostics window Fig 51 HF diagnostics window The following functions can be executed in the HF diagnostics window Icon Function Description Start stop HF diagnostic Starts or closes the HF diagnostics Delete values Deletes the displayed values ...

Page 48: ...ws the available information on the device according to the selected access level 7 4 Setting the IP address The IP address can be set via the Turck Service tool or via DHCP 7 4 1 Setting the IP address via the Turck Service Tool Connect the device to a PC via the Ethernet interface Launch the Turck Service Tool Click Search or press F5 Fig 52 Turck Service Tool Start screen The Turck Service Tool...

Page 49: ...V01 00 2019 04 49 Change the IP address and if necessary the network mask and gateway Accept the changes by clicking Set in device Fig 53 Turck Service Tool Changing the device configuration ...

Page 50: ...on 24V Output 88 0 Output off 0V 1 Output on 24V DXP1 Input 60 0 Input off 0V 1 Input on 24V Output 89 0 Output off 0V 1 Output on 24V DXP2 C1 Input 57 0 Input off 0V 1 Input on 24V Output 86 0 Output off 0V 1 Output on 24V DXP3 Input 58 0 Input off 0V 1 Input on 24V Output 87 0 Output off 0V 1 Output on 24V Setting the switchable VAUX power supply Socket Type GPIO Possible values C0 Output VAUX0 ...

Page 51: ...e set transfer rate The speed may possibly not be enough for time critical applica tions To achieve faster data processing the process can be set as a real time pro cess The following example shows the programming of the digital I O channels with Python 3 import sys GPIOs OUT IN ports 88 59 write GPIO try set direction to write DXP fo open sys class gpio gpio ports 0 direction w fo write out fo cl...

Page 52: ...alue fal write 1 fal close read DXP fr open sys class gpio gpio ports 1 value r val fr read fr close print val except export gpio if not done as yet f1 open sys class gpio export w f1 write ports 1 f1 close set direction to read DXP fo open sys class gpio gpio ports 1 direction w fo write in fo close set active low to get the right value fal write 1 fal close read DXP fr open sys class gpio gpio p...

Page 53: ... the digital I O channels with Node js Further information on Node js and the Node js packages is provided at n https nodejs org n https www npmjs com initialize the onoff box const Gpio require onoff Gpio function setGpioByInt OUT val switch from DXP to GPIO switch OUT case 0 res 88 break case 1 res 89 break case 2 res 86 break case 3 res 87 break initialize the GPIO just to write write the GPIO ...

Page 54: ...mmissioning 54 Hans Turck GmbH Co KG T 49 208 4952 0 F 49 208 4952 264 more turck com www turck com initialize the GPIO just to read set active low to get the right value read the GPIO DXP res return res ...

Page 55: ...ccess const char pfad int modus int main void choose DXP GPIO for connection char input 2 READ file doesn t exist export gpio if fh fopen sys class gpio export w fputs 59 fh fclose fh else printf failed on export to read n printf result i n int fh return 1 set direction to read if fh fopen sys class gpio gpio59 direction w fputs in fh fclose fh else printf failed on setting direction to read n ret...

Page 56: ...ts input 2 fh fclose fh printf Value c n input 0 else printf failed on reading n return 1 WRITE file doesn t exist export gpio if fh fopen sys class gpio export w fputs 88 fh fclose fh else printf failed on export to write n printf result i n int fh return 1 set direction to read if fh fopen sys class gpio gpio88 direction w fputs out fh fclose fh else printf failed on setting direction to write n...

Page 57: ...V01 00 2019 04 57 if fh fopen sys class gpio gpio88 value w fputs const char 1 fh fclose fh else printf failed on writing n return 1 ...

Page 58: ... Red run_red If the red and green of an LED are switched on at the same time the LED is orange NOTE During an ongoing firmware update the RUN LED is used by the system 7 6 2 Setting LED functions via a script A script is installed on the device for setting the LEDs The script is located under the following path TURCK scripts led sh The script can be used with the following syntax sh led h led colo...

Page 59: ... for 5 seconds time sleep 5 write green LEDs fw open sys class leds appl_green brightness w fw write 1 fw close fw open sys class leds err_green brightness w fw write 1 fw close fw open sys class leds run_green brightness w fw write 1 fw close Wait for 5 seconds time sleep 5 clean red LEDs fw open sys class leds run_red brightness w fw write 0 fw close fw open sys class leds appl_red brightness w ...

Page 60: ...ode js The following examples illustrate the programming of the LED functions with Node js Further information on Node js and the Node js packages is provided at n https nodejs org n https www npmjs com initialize the onoff box const Gpio require onoff Gpio initialize the leds which are free for the user appl_green_led new LED appl_green appl_red_led new LED appl_red error_green_led new LED err_gr...

Page 61: ...appl_green char appl_red_led appl_red char error_green_led err_green char error_red_led err_red char run_green_led run_green char run_red_led run_red char LED_FILE sys class leds char brightness brightness FILE fh char cur_Str 50 0 strcpy cur_Str LED_FILE take LED which will shine strcat cur_Str run_red_led strcat cur_Str brightness WRITE printf string to led s n cur_Str write LED if fh fopen cur_...

Page 62: ... file with the following toolchain command opt OSELAS Toolchain 2014 12 0 arm cortexa8 linux gnueabihf gcc 4 9 2 glibc 2 20 binutils 2 24 kernel 3 16 sanitized bin arm cortexa8 linux gnueabihf gcc o helloExample hello c Example Creating a C program via a make file The make service program automates the creation of executable files from source code C programs can be compiled via make This uses a ma...

Page 63: ...nterface is restarted ExecStart path_to_programm app file A parameter can be transferred if required Example ExecStart path_to_programm app file parameter Further information on unit configuration files is available at https www freedesktop org software systemd man systemd service html Example Autostart of an application with a parameter transfer ExecStart usr bin node home user hello_GPIO js weba...

Page 64: ...ndard Linux user management The access rights can be managed with the following standard Linux tools n adduser n addgroup n passwd User Rights Password root System administrator all ac cess rights turck user Restricted access rights and console rights password sftpuser Access rights SFTP rights in the directory home password 7 10 Installing Python packages Modules libraries and other software can ...

Page 65: ...Name E Mail ptxdist enter package section Python3 generating rules sh make generating rules sh in The sh make and sh in files are created automatically If known enter the key of the package as a SH_MD5 parameter in the sh make file Set the SH_CONF_TOOL parameter in the sh make file to the appropriate tool in this case Python 3 SH_CONF_TOOL python3 If a Python module has a separate subfolder Create...

Page 66: ...g with the following command ptxdist menuconfig Navigate to the Python 3 modules via Scripting Languages Ò python3 Extra Mod ules Select the sh module Save the configuration Fig 54 PTXdist Python 3 Extra Modules Generate ipkg packages with the following command ptxdist go a If no errors have occurred the package with the sh module can be found at platform tben lx linux packages ls platform tben lx...

Page 67: ...to the TBEN device in order to install the sh_1 12 14_armhf ipk package Call up the ipkg manager to install the Python module ipkg force depends install sh_1 12 14_armhf ipk a The module is available in the Python Interpreter ...

Page 68: ...ng Off Wireless field deactivated Green Wireless field activated DATA LED Meaning Off No tag in the field no data transfer Yellow flashing Tag in the field data transfer via the air interface DIAG LED Meaning Off No error Red Error The following multicolor LEDs are freely programmable The tables below describe the default display functions DXP LEDs digital channels LEDs DXP0 3 LED green LED red Me...

Page 69: ...first check whether ambient interference is present If there is no ambient interference present check the connections of the device for faults If there are no faults there is a device malfunction In this case decommission the device and replace it with a new device of the same type ...

Page 70: ...OTICE Interruption of the power supply during the firmware update Risk of device damage due to faulty firmware update Do not interrupt the power supply during the firmware update During the firmware update do not reset the power supply Connect the device to a PC via the Ethernet interface Call the web server of the device Enter the IP address of the device in the address line of the browser or sta...

Page 71: ...V01 00 2019 04 71 Click File Upload Ò Select File Fig 56 Web server Upload function Select the update file on the host PC Fig 57 Selecting the update file ...

Page 72: ...208 4952 0 F 49 208 4952 264 more turck com www turck com Load the update file on the device Click Upload Fig 58 Web server Loading the update file on the device Install the update file Click Install Fig 59 Web server Installing the update file ...

Page 73: ...V01 00 2019 04 73 Restart the device to complete the update Click Reboot Fig 60 Restarting the device ...

Page 74: ...device and the latest firmware can be downloaded free of charge from www turck com NOTICE Interruption of the power supply during the firmware update Risk of device damage due to faulty firmware update Do not interrupt the power supply during the firmware update During the firmware update do not reset the power supply Example Update the firmware with the PACTware FDT frame application Launch PACTw...

Page 75: ...V01 00 2019 04 75 Select RS485 RFID and confirm with OK Fig 62 Selecting the RS485 interface ...

Page 76: ...Maintenance 76 Hans Turck GmbH Co KG T 49 208 4952 0 F 49 208 4952 264 more turck com www turck com Right click RS485 RFID Click Add device in the context menu Fig 63 Adding a read write head ...

Page 77: ...elect the required read write head Fig 64 Example Selecting a read write head Right click TN UHF Q300 EU Establish connection to the host PC Click Establish connection in the context menu Fig 65 Establishing a connection ...

Page 78: ... T 49 208 4952 0 F 49 208 4952 264 more turck com www turck com Right click TN UHF Q300 EU In the context menu choose Other Functions Ò RFID Test Fig 66 Starting the RFID test Click Firmware Update Fig 67 Firmware Update Opening the menu ...

Page 79: ...V01 00 2019 04 79 Click the Select BL File button Fig 68 Button Selecting a BL file Select the update file from the local memory location Fig 69 Local memory location of the update file ...

Page 80: ... com www turck com Start the update Click Firmware update Fig 70 Starting the firmware update A completed firmware update is indicated by a status message and a yellow progress bar in the DTM Fig 71 Successful firmware update Reset the read write head to complete the firmware update ...

Page 81: ...turns to Turck can only be accepted if the device has been equipped with a Decontamination declaration enclosed The decontamination declaration can be downloaded from https www turck de en retoure service 6079 php and must be completely filled in and affixed securely and weather proof to the outside of the packaging 12 Disposal The devices must be disposed of correctly and must not be included in ...

Page 82: ...al Aluminum AL silver Material of active face Fiber glass reinforced polyamide PA6 GF30 black Vibration resistance 55 Hz 1 mm Shock resistance 30 g 11 ms Protection class IP67 No of channels 4 Electrical connection RP TNC Input impedance 50 Ω System description Processor ARM Cortex A8 32 bit 800 MHz ROM memory 512 MB Flash RAM memory 512 MB DDR3 System data Ethernet transfer rate 10 Mbit s 100 Mbi...

Page 83: ...V01 00 2019 04 83 Technical Data No of channels 4 Connection technology of outputs M12 5 pin Output type PNP Type of output diagnostics Channel diagnostics ...

Page 84: ...ck com www turck com 14 EU Declaration of Conformity Hans Turck GmbH Co KG hereby declares that wireless system read write heads of type TN UHF Q L EU comply with directive 2014 53 EU The complete text of the EU declaration of conformity can be obtained from the following Internet address www turcks com ...

Page 85: ...Over 30 subsidiaries and over 60 representations worldwide www turck com 100003067 2019 04 100003067 ...

Reviews: