Commissioning
50
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
7.5
Programming digital channels (DXP)
7.5.1
GPIOs of the DXP channels – Overview
The digital I/O channels (DXP) can be programmed as inputs or outputs via the GPIOs. The
GPIOs are located under the following path:
/sys/class/gpio/…
Channel
Socket
Type
GPIO
Possible values
DXP0
C0
Input
59
0: Input off (0V)
1: Input on (24V)
Output
88
0: Output off (0V)
1: Output on (24V)
DXP1
Input
60
0: Input off (0V)
1: Input on (24V)
Output
89
0: Output off (0V)
1: Output on (24V)
DXP2
C1
Input
57
0: Input off (0V)
1: Input on (24V)
Output
86
0: Output off (0V)
1: Output on (24V)
DXP3
Input
58
0: Input off (0V)
1: Input on (24V)
Output
87
0: Output off (0V)
1: Output on (24V)
Setting the switchable VAUX power supply
Socket
Type
GPIO
Possible values
C0
Output VAUX0
41
0: VAUX off
1: VAUX on
Output VAUX1
40
Setting the switchable VAUX power supply – Diagnostics
Socket
Type
GPIO
Possible values
C0
Input VAUX0
56
0: VAUX error-free
1: Error or overvoltage
on VAUX
Input VAUX1
55