Connecting
Connecting the supply voltage
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | [email protected] | www.turck.com
V01.00 | 2022/09 | 11
6
Connecting
NOTICE
Intrusion of liquids or foreign bodies through leaking connections
Loss of protection class IP65/IP67/IP69K, device damage possible
Tighten M12 connectors with a tightening torque of 0.6 Nm.
Only use accessories that guarantee the protection class.
Always seal unused connectors with suitable screw caps or blind caps. The tight-
ening torque for the screw caps is 0.5 Nm.
6.1
Connecting the supply voltage
For the connection to the power supply, the device has a 7/8" connector. The connector is de-
signed as 4-pin (TBIL-L4) or 5-pin (TBIL-L5) connector. V1 and V2 are galvanically isolated from
each other. The maximum tightening torque is 0.8 Nm.
Fig. 4: TBIL-L4… – 7/8” connector (P2) for connecting the supply voltage
Fig. 5: TBIL-L5… – 7/8” connector (P2) for connecting the supply voltage
Connect the device to the power supply according to the pin assignment.
1 = 24 VDC (V2)
2 = 24 VDC (V1)
3 = GND (V1)
4 = GND (V2)
2
1
4
3
Fig. 6: TBIL-L4– Pin assignment supply voltage (P2)
1 = GND (V2)
2 = GND (V1)
3 = FE
4 = 24 VDC (V1)
5 = 24 VDC (V2)
5
4
1
2
3
Fig. 7: TBIL-L5– Pin assignment supply voltage (P2)