background image

Your Global Automation Partner

Instructions for Use

TBIP-L…-16DXP-AUX

I/O Hub with IO-Link

Summary of Contents for BIL-L4-16DXP-AUX

Page 1: ...Your Global Automation Partner Instructions for Use TBIP L 16DXP AUX I O Hub with IO Link...

Page 2: ...8 4 1 1 Display elements 8 4 2 Properties and features 9 4 3 Functions and operating modes 9 5 Installing 10 6 Connecting 11 6 1 Connecting the supply voltage 11 6 1 1 Supply concept 12 6 2 Connecting...

Page 3: ...more turck com www turck com V01 00 2022 09 3 9 4 Diagnostic data 26 9 5 IO Link error codes 27 10 Troubleshooting 28 11 Maintenance 29 12 Repair 29 12 1 Returning devices 29 13 Disposal 29 14 Technic...

Page 4: ...Table of Contents Hans Turck GmbH Co KG T 49 208 4952 0 more turck com www turck com V01 00 2022 09 4...

Page 5: ...NG WARNING indicates a dangerous situation with medium risk of death or severe in jury if not avoided CAUTION CAUTION indicates a dangerous situation of medium risk which may result in minor or modera...

Page 6: ...e of delivery includes n I O hub n Dummy plugs for M12 connectors n Label clips n Quick Start Guide 2 3 Turck service Turck supports you with your projects from initial analysis to the commissioning o...

Page 7: ...ted applications n For the use in safety applications Observe chapter Using the device in safety applications n The device is part of a safety related overall system The overall system must always be...

Page 8: ...r via an M12 socket An additional 7 8 connector is available for connecting the auxiliary voltages V1 and V2 to supply connected field devices The devices are designed in a fully encapsulated housing...

Page 9: ...nels per connector n Metal connectors 4 3 Functions and operating modes The I O hub TBIL L 16DXP AUX is an IO Link Class A device with three galvanically isolated supply voltages V1 V2 VIOL The connec...

Page 10: ...0 5 Installing The device is mounted via two M4 screws on a flat and pre drilled mounting surface Fasten the module to the mounting surface with two M4 screws The maximum tighten ing torque for the sc...

Page 11: ...screw caps is 0 5 Nm 6 1 Connecting the supply voltage For the connection to the power supply the device has a 7 8 connector The connector is de signed as 4 pin TBIL L4 or 5 pin TBIL L5 connector V1...

Page 12: ...y shutdown of parts of an installation via emergency off circuits V1 Supply of connectors C0 C3 and the connected sensors and actuators V2 Supply of connectors C4 C7 and the connected sensors and actu...

Page 13: ...Fig 12 Pin assignment TBIL L 16DXP AUX C0 C3 Fig 13 M12 connector for connecting digital sensors and actuator C4 C7 1 VAUX2 V2 2 In Out odd 3 GND V2 4 In Out even 5 FE C4 C7 4 3 2 1 5 Fig 14 Pin assi...

Page 14: ...olation of load and operating voltage the design of the devices allows the fault exclusion of voltage carry over to safely disconnected equipment with a single fault safety of category 3 for safety fu...

Page 15: ...with cross circuit protection if the safe installation of the cables is not possible 7 3 2 Switch off supply voltage safely WARNING 1 pole switch off the supply voltage Safe separation not guaranteed...

Page 16: ...2061 2005 A1 2012 A2 2015 Safety of machinery Functional safety of safety related electrical electronic and programmable electronic control systems DIN EN 61508 2011 IEC 61508 2010 Functional safety o...

Page 17: ...P AUX 0xE330 0x0B 0x0C IO Link object directory ISDU device parameters Identification ISDU Index Hex dec Object name Access Length in bytes Meaning default value Comment 0x10 16 Vendor name read only...

Page 18: ...cess Length in bytes Meaning 0x40 64 Parameter ID read write 4 Customer specific ID for free use 0x41 65 Inverting input read write 2 Invert digital input 0x42 66 Activate output read write 2 Activate...

Page 19: ...A C3P2 B C3P4 A C2P2 B C2P4 A C1P2 B C1P4 A C0P2 B C0P4 A Activate output 0x42 66 sub index 0 This parameter activates or deactivates the output function of the digital channel Format Length Byte 2 by...

Page 20: ...P2 B C6P4 A C5P2 B C5P4 A C4P2 B C4P4 A C3P2 B C3P4 A C2P2 B C2P4 A C1P2 B C1P4 A C0P2 B C0P4 A NOTE This parameter can also be set for all connectors of the module via the IODD Manual output reset af...

Page 21: ...te 2 bit per channel Default values are shown in bold Value Meaning 00 0 Set output to 0 01 1 Set output to 1 10 Current value Hold current value 11 reserved Byte 0 Byte 1 Byte 2 Byte 3 Bit offset 6 4...

Page 22: ...shold values for undervoltage diagnostics for V1 V2 and VIOL Format Length Array of byte 2 byte 3 bit per module Default values are shown in bold Value Meaning Activate undervoltage diagnostics 0 No 1...

Page 23: ...ent sensor supply 3 Overcurrent C7 Overcurrent C6 Overcurrent C5 Overcurrent C4 Overcurrent C3 Overcurrent C2 Overcurrent C1 Overcurrent C0 Channel diagnostics overcurrent output 4 Overcurrent C3P2 Ov...

Page 24: ...e sensor actuator supply at the connector At mod ules with group diagnostics all connector LEDs of the supply group flash simultaneously in case of an error Channel diagnostics overcurrent output Over...

Page 25: ...ent Red IO Link communication error or module error Red flashing 1 Hz IO Link communication OK invalid process data or diagnostic message Off No voltage supply 9 3 2 Channel LEDs LED 0 15 Meaning inpu...

Page 26: ...Undervoltage V1 per module n Undervoltage V2 per module n Undervoltage VIOL per module n Overcurrent sensor supply per connector Format Length Array of bytes 2 byte 0 no diagnostics 1 diagnostic messa...

Page 27: ...ur rent C1P4 Overcur rent C0P2 Overcur rent C0P4 Byte 1 Bit offset 7 6 5 4 3 2 1 0 Overcur rent C7P2 Overcur rent C7P4 Overcur rent C6P2 Overcur rent C6P4 Overcur rent C5P2 Overcur rent C5P4 Overcur r...

Page 28: ...the device does not function as expected first check whether ambient interference is present If there is no ambient interference present check the connections of the device for faults If there are no...

Page 29: ...d if it is faulty Observe our return acceptance conditions when returning the device to Turck 12 1 Returning devices Returns to Turck can only be accepted if the device has been equipped with a Decont...

Page 30: ...l pnp inputs EN 61131 2 Type of input diagnostics Channel diagnostics Signal voltage low level 3 5 VDC EN 61131 2 type 1 and 3 Signal voltage high level 11 30 VDC EN 61131 2 type 1 and 3 Input current...

Page 31: ...N 60068 2 6 Shock test According to EN 60068 2 27 Drop and topple According to IEC 60068 2 31 IEC 60068 2 32 Electromagnetic compatibility According to EN 61131 2 6 4 Approvals CE cULus General Inform...

Page 32: ...Appendix Hans Turck GmbH Co KG T 49 208 4952 0 more turck com www turck com V01 00 2022 09 32...

Page 33: ...nada Inc 140 Duffield Drive CDN Markham Ontario L6G 1B5 www turck ca China Turck Tianjin Sensor Co Ltd 18 4th Xinghuazhi Road Xiqing Economic Development Area 300381 Tianjin www turck com cn Czech Rep...

Page 34: ...uiterlaan 7 NL 8019 BN Zwolle www turck nl Poland TURCK sp z o o Wroclawska 115 PL 45 836 Opole www turck pl Romania Turck Automation Romania SRL Str Siriului nr 6 8 Sector 1 RO 014354 Bucuresti www t...

Page 35: ...Over 30 subsidiaries and 60 representations worldwide www turck com 100019421 2022 09 100019421...

Reviews: