40
OVEn SySTEMS
Magnetron Thermostats
The magnetron thermostats are “open-on rise.”
They are designed to open at 270ºF (132ºC), which
triggers an F5 fault.
NOTE: The magnetron thermostats are wired in
series. If one opens, the control will switch off both
magnetrons until the open thermostat closes. The
thermostats are self-resetting.
Testing a Magnetron for an Open/Shorted
filament
DANGER: The only safe way to test a
magnetron is by a resistance test of its
filament. Never attempt to measure the
magnetron using any other method while the
microwave system is on. Death or serious
injury will occur.
1. Disconnect the AC power source and discharge
the high-voltage capacitors.
2. Isolate the magnetron from the circuit by
removing the wires from the F and FA terminals
(Figure 31).
3. An ohmmeter connected between the filament
terminals (F, FA) should indicate a reading of less
than 1 Ω (Figure 31).
4. A continuity check between either filament
terminal and the magnetron chassis should
indicate an infinite resistance (open).
CAUTION: Do not allow debris to enter
the waveguides when servicing the
magnetrons.
Relay - K1 filament
The K1 relay is a 240 VAC, 24 VDC coil, 20 amp,
sealed double-pole, double-throw relay. It switches
power to the filament transformers.
Relay - K2 Anode
The K2 relay is a 240 VAC, 30 amp, double-pole,
double-throw, 24 VDC relay coil. It switches power
to the high-voltage transformers.
Relay - K7 Cooling fans
The K7 relay is 240 VAC, 24 VDC coil, 20 amp,
sealed single-pole relay. It switches power to the
magnetron cooling fans when the magnetron
filaments are actuated. Power is switched off after
four minutes and fifteen seconds.
NOTE: The four-minute, fifteen-second timer starts
over each time the magnetron filaments are actuated.
NOTE: The magnetron cooling fans are actuated by
the K7 relay when the EC temperature exceeds 120°F
(49°C), regardless of magnetron operation.
Waveguides
The waveguides channel microwaves into the cook
cavity. If debris or contamination gets into the wave-
guides, the life of the magnetrons will be shortened.
Be careful to not allow debris into the waveguides
when servicing the magnetrons.
Troubleshooting
The following faults may occur in relation to the
microwave system:
- F3: Magnetron Current Low (see page 49)
- F5: Magnetron Over Temperature (see page 50)
The following issues may occur in relation to the
microwave system:
- Electrical component failure (blank or
scrambled display, damaged control board, etc.)
- Food not cooking properly (see page 60)
filament and High
Voltage Terminals
Antenna
figure 31: Magnetron Detail
Summary of Contents for Encore Touch Rapid
Page 12: ...iv safety instructions This page intentionally left blank...
Page 13: ...Specifications and Installation...
Page 14: ......
Page 19: ...Daily and Quarterly Maintenance...
Page 20: ......
Page 24: ...8 cleaning This page intentionally left blank...
Page 25: ...Oven Controls and Cooking...
Page 26: ......
Page 33: ...Info Mode...
Page 34: ......
Page 43: ...Edit Mode...
Page 44: ......
Page 54: ...32 edit mode This page intentionally left blank...
Page 55: ...Oven Systems...
Page 56: ......
Page 68: ...44 oven systems This page intentionally left blank...
Page 69: ...Troubleshooting...
Page 70: ......
Page 88: ...62 troubleshooting This page intentionally left blank...
Page 89: ...Oven Schematic and Wire Harnesses...
Page 90: ......
Page 92: ...64 OVEN SCHEMATIC AND WIRE HARNESSES...
Page 97: ...Appendix Replacing Oven Components...
Page 98: ......
Page 114: ...A 16 appendix replacing oven components This page intentionally left blank...
Page 115: ......