![TurboChef Encore Touch Rapid Service Manual Download Page 60](http://html1.mh-extra.com/html/turbochef/encore-touch-rapid/encore-touch-rapid_service-manual_1181180060.webp)
36
OVEn SySTEMS
Measuring Rf Leakage for Microwave Safety
WARNING: This procedure requires work with
hot surfaces and water loads. To avoid burns, be
careful when testing.
An RF (microwave) leakage test must be performed at
the conclusion of the following service tasks:
- Door removal, replacement and/or adjustment
- Waveguide removal and/or replacement
- Magnetron removal and/or replacement
- Door switch adjustment and/or replacement
WARNING: If the unit fails the microwave
leakage test (leakage greater than 5mW/cm
2
),
the oven must be taken out of service
immediately until the defect is corrected. In
addition, the CDRH Regulation 21 Subpart C,
1002.20 requires that leakage readings of over
5mW/cm
2
must be reported to the manufacturer.
To measure RF leakage,
1. Turn the oven on and allow it to warm up to the
set temperature (approximately 15 minutes if the
oven starts cold).
2. Once the oven has warmed up, place the oven
in Manual Mode (page 13).
3. From Manual Mode, create a 1 minute
recipe with a single event, 10% air, and 30%
microwave (Figure 28, below).
4. Place a water load into the cook cavity. The
water load must conform to the following
specifications:
- Volume: 275 ml ± 15 ml (1 cup/8 fl oz)
- Temperature: 68ºF ± 9ºF (20ºC ± 5ºC)
- Vessel: Low form, 600 ml beaker with an
inside diameter of approximately 3.35”
(85 mm) and made of Pyrex or equivalent.
5. Close the oven door and press the Cook key.
The microwave system will turn on.
6. Measure microwave emission around the door as
shown in the adjacent illustration, moving the
meter sensor at 0.5 inches/second.
7. As microwave leakage is observed while moving
the sensor, note any meter spike areas that come
close to 5mW/cm
2
for later re-measurement.
8. Replace the water load every 60 seconds until the
test is completed, and also after scanning the door.
9. Close the oven door and return the meter probe
to any “meter spike” areas and allow the probe to
remain in the “spike” area for 17 seconds. Note
the highest reading obtained.
NOTE: There may be several places on the door
where this procedure needs to be done. If so, start out
with a fresh water load each time a new area is mea-
sured, or if measurement of an area takes longer than
60 seconds.
10. After each test is complete, open the oven door
and dispose of the hot water.
Troubleshooting
The following faults may occur in relation to the oven
door:
- F4: Monitor (see page 36)
The following issues may occur in relation to the oven
door:
- “Cook Door Open” message when door is
closed (see page 36)
figure 29: Measure for Microwave Leakage
figure 28: Settings for Rf Leakage Test
Summary of Contents for Encore Touch Rapid
Page 12: ...iv safety instructions This page intentionally left blank...
Page 13: ...Specifications and Installation...
Page 14: ......
Page 19: ...Daily and Quarterly Maintenance...
Page 20: ......
Page 24: ...8 cleaning This page intentionally left blank...
Page 25: ...Oven Controls and Cooking...
Page 26: ......
Page 33: ...Info Mode...
Page 34: ......
Page 43: ...Edit Mode...
Page 44: ......
Page 54: ...32 edit mode This page intentionally left blank...
Page 55: ...Oven Systems...
Page 56: ......
Page 68: ...44 oven systems This page intentionally left blank...
Page 69: ...Troubleshooting...
Page 70: ......
Page 88: ...62 troubleshooting This page intentionally left blank...
Page 89: ...Oven Schematic and Wire Harnesses...
Page 90: ......
Page 92: ...64 OVEN SCHEMATIC AND WIRE HARNESSES...
Page 97: ...Appendix Replacing Oven Components...
Page 98: ......
Page 114: ...A 16 appendix replacing oven components This page intentionally left blank...
Page 115: ......