ConnectMe Tunstall Vi+ Installation and Programming Manual
62
KB
Ringing end
057
System status
00
Normal default
Kb
General Alarm
010
Fixed trigger 1
00
Normal default
Kd
Away State entry
057
System status
00
Normal default
KE
Home State entry
057
System status
00
Normal default
Ke
Call Raised
057
System status
00
Normal default
KF
Call Selected
057
System status
00
Normal default
Kf
Call Cleared
057
System status
00
Normal default
KG
Speech Module Selected
057
System status
00
Normal default
Kg
System onsite
057
System status
00
Normal default
KH
System offsite
057
System status
00
Normal default
Kh
Dialling complete
057
System status
00
Normal default
KI
Protocol complete
057
System status
00
Normal default
Ki
TT New Acceptor Code 0 (D)
057
System status
00
Normal default
KJ
TT New Acceptor Code 3 (D/G)
057
System status
00
Normal default
Kj
TT New Acceptor Code 6 (D)
057
System status
00
Normal default
KL
TT New Acceptor Code A (D)
057
System status
00
Normal default
Kl
TT New Acceptor Code B (D)
057
System status
00
Normal default
KM
TT New Acceptor Code C (D)
057
System status
00
Normal default
Km
TT New Acceptor Code D (D)
057
System status
00
Normal default
KN
TT New Acceptor Code * (D)
057
System status
00
Normal default
Kn
TT New Acceptor Code 8 (G)
057
System status
00
Normal default
KO
TT New Acceptor Code A (G)
057
System status
00
Normal default
Ko
TT New Acceptor Code C (G)
057
System status
00
Normal default
KP
TT New Acceptor Code E (G)
057
System status
00
Normal default
Kp
TT New Acceptor Code * (G)
057
System status
00
Normal default
K0
Momentary offsite
057
System status
00
Normal default
K1
Intruder system armed
057
System status
00
Normal default
K2
Intruder system disarmed
057
System status
00
Normal default
K3
Carer Left
099
Service incompleted
00
Normal default
K4
Intruder Timeout
057
System status
00
Normal default
K5
Keyless Access
057
System status
00
Normal default
K6
Concierge Call
010
Fixed trigger 1
00
Normal default
K7
Information Call (likely to be
removed)
057
System status
00
Normal default
K8
Ademco Reset
057
System status
00
Normal default
K9
Ademco Timeout
057
System status
00
Normal default
LA
Telelarm Low Battery
057
System status
00
Normal default
La
Confirmation - Call Cleared
057
System status
00
Normal default
LB
Confirmation - Call Raised
057
System status
00
Normal default
Lb
Incoming call answered
057
System status
00
Normal default
LC
Incoming call cleared
057
System status
00
Normal default
Lc
Outgoing call started
057
System status
00
Normal default
LD
Outgoing call finished
057
System status
00
Normal default
Ld
Poll Voice Server
057
System status
00
Normal default
LE
IP Module Fail
062
IP communication Link
00
Normal default
Le
IP Connectivity Fail
062
IP communication Link
06
Fault status (alarm not active)
LF
IP Connectivity Restored
062
IP communication Link
04
In service (fault rectified)
Lf
PNC Contact
062
IP communication Link
00
Normal default
LG
Unknown Trigger Alarm
010
Fixed trigger 1
00
Normal default
Lg
Roaming Alarm
010
Fixed trigger 1
00
Normal default
LH
LAN Fail Alarm
062
IP communication Link
00
Normal default
Lh
PBX Fail Alarm
062
IP communication Link
00
Normal default
LI
Test Alarm (Red Button)
010
Fixed trigger 1
00
Normal default
Li
Test Alarm (Pendant)
010
Fixed trigger 1
00
Normal default
LJ
Test Alarm Not Confirmed (Red
Button)
010
Fixed trigger 1
00
Normal default
Lj
Test Alarm Not Confirmed
(Pendant)
010
Fixed trigger 1
00
Normal default
Lm
Radio Blocking
061
Radio receiver
06
Fault status (alarm not active)