ConnectMe Tunstall Vi+ Installation and Programming Manual
19
Step 2
– Enter commands via the keypad (Refer to Installer keypad section for more
detail)
Frequently used series telephone codes
Enter programming mode as described on the previous page, lift the telephone
handset and then enter the following codes:
Resetting the home unit but retaining radio triggers
To reset all previous programmed information except the radio triggers, press:
This code means all functions are reset to default settings. The date and time remain
unchanged.
Resetting the home unit
To reset all previous programmed information press:
Resetting erases all programmed telecare sensors and triggers and all functions are
reset to default settings. The date and time remain unchanged.
Setting the time and date
There is a real time 24 hour clock in the home unit which automatically adjusts to
AEST During power cuts the clock is ba
cked up by the home unit’s battery for up to
40 hours. However if the unit is powered down for transit then the clock must be reset
again when the home unit is installed in the user’s home. Once the time has been set
the time can be checked by using the quick code 3020. The unit will then announce
the date and time. During the first 30 minutes of installation the Tunstall Vi+ will also
announce the date and time when an incoming telephone call is received (requires
CLI on the telephone line). To set the clock press:
DDMMYY HH MM X Y
DD represents the day of the month (01-31)
MM represents the months (01-12)
YY represents the two digit year (00-99)
HH represents hours 00-23; 24 cannot be programmed
MM represents minutes 00-59; 60 cannot be programmed
X represents the daylight saving time zone (0 = disabled, 3 = AUS Eastern States, 5 = NZ)
Y represents enable/disable auto CLI time update feature (0 = disable, 1 = enable)