The TM2-box needs configuration before it is ready to use. The configuration requires an 

Android application especially made for that purpose. Please contact the Tunstall office in 

Malmö for details about the application. 

Tx75 transmitters 

There are many different Tx75 transmitters and most of them can be reprogrammed to act 

in different ways. The recommended types of transmitters and their IDs for ID-Lock Smart 

are: 

 

K2315-ID4

 or 

K2315-ID2

 with IDs between 

1

 and 

927

 for residents 

 

K2315-ID4M

 with IDs between 

928

 and 

991

 for the staff. 

Make sure you order the correct transmitters with the correct IDs to save the time to 

reprogram them in the field (which requires a special programming box). 

IDT zone-IDs 

The zone-ID that is transmitted from the IDT is set by dip-switches inside the IDT. There are 

10 switches, representing 10 binary bits with the least significant bit to the left (i.e. the 

reverse from how a binary number is normally represented in writing). 

The zone-ID range that normally should be used for ID-Lock is 

768

 to 

910

. Other zones may 

cause the Tx75 transmitter to behave in undesired ways. 

 

 

 

 

 

 

 

 

 

Tunstall AB

 

Box 9028 

Tel: 040-625 25 00 

200 39 Malmö 

[email protected] 

Visiting address: Agnesfridsvägen 113 A 

www.tunstallnordic.com 

Summary of Contents for 036-01-835

Page 1: ...ID Lock Smart Installation guide Version 1 3...

Page 2: ...bers 5 Split mechanics 036 01 835 or 036 01 836 5 Handles 346 60 04 95 cover plate 346 60 04 96 5 Carelock ACE Split 036 01 902 5 TM2 box 046 01 803 5 IDT K2415 5 Exploded view of the Split mechanics...

Page 3: ...y just pulling the door handle without any key or transmitter while the outside handle only works when the door is unlocked Many hotel rooms use this same functionality The residents only need to wear...

Page 4: ...as an ID that is unique for each transmitter on a site The staff Tx75 transmitters work the same way except they do not automatically transmit anything you must push the transmitter s button to trigge...

Page 5: ...Steel wires and the screws are the only parts that differs depending on door thickness Handles 346 60 04 95 cover plate 346 60 04 96 Most existing handles do not have a strong enough return spring whi...

Page 6: ...f the Split mechanics Item Name 1 Satellite bottom 2 Top cabinet 3 Main spindle 4 Circlip 5 Wire sleeve 6 Tooth module 7 Support roller 8 Steel wire 9 Spring 10 Outer wire sleeve 11 Outer spacer 12 Ou...

Page 7: ...box Other examples are to mount it inside a plastic box or hide it above the ceiling Make a simple mounting plate by using a metal or plastic plate that you drill holes in and attach to the TM2 box wi...

Page 8: ...each other in e g a corridor then it is important that all IDTs are mounted on the same side of their respective door Two IDTs must never be closer than 1 meter from each other It may be necessary to...

Page 9: ...ock Smart Installation guide Ver 1 3 9 Step by step installation of the Carelock ACE Split Step 1 Remove the inside thumbturn knob and the exterior cylinder housing which is fastened with the same scr...

Page 10: ...2 Unscrew the thumbturn spindle bracket The lock cylinder on the doors exterior is fastened with the same screws as the thumbturn spindle bracket so you want to hold the lock cylinder in place while y...

Page 11: ...ID Lock Smart Installation guide Ver 1 3 11 and remount the bracket with the same screws that also holds the lock cylinder Step 3 Remove the handles and the spindle...

Page 12: ...ID Lock Smart Installation guide Ver 1 3 12 Step 4 Prepare the satellite part by first mounting the support roller and then sliding on the tooth module Step 5 Mount the circlip on the outer spindle...

Page 13: ...Smart Installation guide Ver 1 3 13 Step 6 Place the steel wires inside the outer wire sleeve Step 7 Temporarily use the outer spindle to hold the steel wires in place by sliding it into the outer wir...

Page 14: ...ID Lock Smart Installation guide Ver 1 3 14 Step 7 Slide the spring on to the outer wire sleeve Step 8 Thread the outer wire sleeve assembly through the door from the outside...

Page 15: ...ugh the tooth module It is easier to do this if you first rotate the satellite assembly and then adjust it to a vertical position Step 10 Mount the wire sleeve on the tooth module and make sure the st...

Page 16: ...ID Lock Smart Installation guide Ver 1 3 16 Step 11 Mount the circlip onto the main spindle followed by a shim washer...

Page 17: ...Lock Smart Installation guide Ver 1 3 17 Step 12 Now press the main spindle assembly through the top cabinet It may be a narrow fit so some light force may be needed Step 13 Mount the other shim wash...

Page 18: ...14 Slide the top cabinet assembly through the door Rotate the main spindle so that the steel wires can slide through the cavity in the main spindle Catch the outer spindle on the outside of the door t...

Page 19: ...uter wire sleeve toward the door and while holding it depressed turn the cogwheel that protrudes from the bottom of the top cabinet assembly clockwise Then without letting go of the cogwheel release t...

Page 20: ...etween 180 to 270 degrees to of a turn and make sure it is aligned with the main spindle the outer wire sleeve should be able to slide over the outer spindle Step 18 Now release the outer wire sleeve...

Page 21: ...ID Lock Smart Installation guide Ver 1 3 21 Step 19 Place the door plate on the outside of the door and remount the exterior cylinder housing that will keep the door plate in place...

Page 22: ...r cylinder housing at this stage you must be able to move around the door plate to be able to fit the outer spacer Step 20 Mount the new handles from the ID Lock Smart kit starting with the inside of...

Page 23: ...rotrude beyond the outer spacer more than 4 mm Step 22 Now mount the limiting bracket so that the spindle can rotate equally in both directions before the limiting bracket hits the outer spacer It is...

Page 24: ...ID Lock Smart Installation guide Ver 1 3 24 Step 23 Mount the outer handle and the nipples Step 24 Tighten the screws holding the exterior cylinder housing and cover plate...

Page 25: ...ID Lock Smart Installation guide Ver 1 3 25 Step 25 Mount the Carelock ACE Split unit with the Torx screw from the kit...

Page 26: ...26 Step 26 Mount the battery in the battery cabinet as shown here Note that the battery should slide into the cabinet with the cable first Step 27 Snap the battery cabinet to the Carelock ACE Split un...

Page 27: ...etween 1 and 927 for residents K2315 ID4M with IDs between 928 and 991 for the staff Make sure you order the correct transmitters with the correct IDs to save the time to reprogram them in the field w...

Reviews: