background image

600A  AC CLAMP METER

AUTO RANGING

PART NO:  

TTICM1000V 

(..151477)

OPERATING

INSTRUCTIONS

Summary of Contents for PROFESSIONALS TTICM1000V

Page 1: ...600A AC CLAMP METER AUTO RANGING PART NO TTICM1000V 151477 OPERATING INSTRUCTIONS...

Page 2: ...rement 9 AC Voltage Measurement 10 DC Voltage Measurement 11 Resistance Measurement 12 Continuity Testing 13 Diode Testing 14 Capacitance Measurement 15 Non Contact AC Voltage Detecting NCV 16 TECHNIC...

Page 3: ...them carefully and strictly observes all warnings and notes INTENDED USE The clamp meter is to be used only for electrical inspection within the specifications the device is rated for Failure to use...

Page 4: ...ng circuits connected to the distribution part of the building s low voltage MAINS installation Check the clamp meter and test leads before using guard against any damage If any abnormalities or damag...

Page 5: ...not measure current in circuits carrying more than 600A with the meter jaw Do not measure voltage or current higher than the allowable input value Disconnect circuit power and discharge all high volta...

Page 6: ...Power supply 3xAAA 1 5V batteries Dimension 228mm x77mm x41mm EXTERNAL OVERVIEW 1 2 4 5 6 7 3 1 Clamp 2 Clamp body Designed to protect operator from touching the dangerous area 3 Clamp Trigger Press...

Page 7: ...h function of the multimeter A short press of the HOLD button once will enter data measurement hold mode press again to exit the data measurement hold mode A long press of this button will turn the ba...

Page 8: ...rement Continuity measurement Relative value measurement k M Resistance unit mV V Voltage unit A mA A Current unit nF F mF Capacitance unit NCV Non contact voltage measurement AUTO Auto ranging Auto p...

Page 9: ...ductor to be measured is clamped at the centre of the clamp 2 Care should be taken to ensure that the clamp is completely closed 3 The current measurement will be shown in the display NOTE Disconnect...

Page 10: ...t NOTE Do not input voltage higher than AC 750V as damage to the meter may result After completing all measurement operations disconnect the test lead from the measured circuit When measured voltage i...

Page 11: ...than 1000V as damage to the meter may result When measuring at mV range relative mode must be used After completing all measurement operations disconnect the test leads from the measured circuit When...

Page 12: ...est lead to V terminal 2 Set the function selector to the measurement setting press SELECT until the resistance icon appears on the display 3 Ensure all power is off in the circuit being measured and...

Page 13: ...to the measurement setting 2 Press SELECT until the screen displays 3 Ensure all power is off in the circuit being measured and that all capacitors have been discharged 4 Measure continuity by connec...

Page 14: ...d black test leads is respectively and 2 Set the function selector to the measurement setting 3 Press SELECT until the screen displays 4 Ensure all power is off in the circuit being measured and that...

Page 15: ...he measurement setting 3 Press SELECT to select connect test leads in parallel with the two terminals of measured capacitance 4 Ensure all power is off in the circuit being measured and that all capac...

Page 16: ...this space place the front end of the clamp meter near the conductor to be tested distance 10mm When an electric field voltage is detected 100vRMS the meter will beep with a red light above the NCV d...

Page 17: ...PECIFICATION AC RANGE RESOLUTION ACCURACY OVERLOAD PROTECTION 6A 0 001A 2 5 30 600A AC VOLTAGE MEASUREMENT RANGE RESOLUTION ACCURACY OVERLOAD PROTECTION 6V 0 001V 1 2 5 1000V DC 750V AC 60V 0 01V 600V...

Page 18: ...RESOLUTION ACCURACY OVERLOAD PROTECTION 99 99nF 0 01nF 4 0 25 1000V DC 750V AC 999 99nF 0 1nF 4 0 5 9 999nF 0 001nF 99 99nF 0 01nF 999 9nF 0 1nF 9 999nF 0 001nF 10 59 99nF 0 01nF For reference only N...

Page 19: ...ally wipe the case with a damp cloth and mild detergent Do not use abrasives or solvents Turn off the power of the meter when it is not in use Remove the battery when the unit won t be in use for exte...

Page 20: ...be excluded under the Australian Consumer Law You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage You are also ent...