TELECOMMUNICATIONS TECHNIQUES CORPORATION
23
3.8 FIREBERD 4000 REMOTE
CONTROL COMMANDS
The FIREBERD 4000 remote control commands enable
remote control over the RS-449/530/MIL Data Interface. The
RS-449/530/MIL Data Interface commands are listed in Table
Table 3-2
RS-449/530/MIL Data Interface FIREBERD 4000 Remote Control Commands
Remote Command
Result
INT SET MIL449 TYP
Prints current interface type setup
INT SET MIL449 TYP (xxxxxx)
Selects the interface type (xxxxxx = 188114, RS449, EIA530, or 188C)
INT SET MIL449 CON
Prints current connector setting
INT SET MIL449 CON (xxx)
Selects the connector type (xxx = DTY [D-type] or TWI [twinax])
INT SET MIL449 EMU
Prints current emulation setup
INT SET MIL449 EMU (xxx)
Selects the type of emulation (xxx = DTE or DCE)
INT SET MIL449 MOD
Prints current mode setting
INT SET MIL449 MOD (xxx)
Selects the mode setting (xxx = BAL or UNBAL)
INT SET MIL449 IMP
Prints the current termination impedance
INT SET MIL449 IMP (xxx)
Selects the termination impedance (xxx = 78, 100, 124, or UNTERM)
INT SET MIL449 TIM
Prints the current timing
INT SET MIL449 TIM (xxx)
Selects the timing (xxx = ASY or SYN)
INT SET MIL449 RCV (xx)
Selects the receive clock source (xx = TT or ST)
INT SET MIL449 DAT
Prints the current data bits setting
INT SET MIL449 DAT (x)
Selects the data bits (x = 5, 6, 7, or 8)
INT SET MIL449 PAR
Prints the current parity setting
INT SET MIL449 PAR (xxx)
Selects the parity (xxx = NON, EVE, or ODD)
INT SET MIL449 STO
Prints the current stop bit setting
INT SET MIL449 STO (xxx)
Selects the stop bit (xxx = 1, 1.5, or 2)
INT SET MIL449 TM (xxx)
Selects the Test Mode ON or OFF
INT SET MIL449 CTS (xxx)
Selects the Clear To Send ON or OFF
INT SET MIL449 LL (xxx)
Selects the Local Loop ON or OFF
INT SET MIL449 RL (xxx)
Selects the Remote Loop ON or OFF
INT MIL449 SIG
Prints the current signaling polarity
INT MIL449 SIG (xxx)
Selects the signaling polarity POS or NEG
3-2. The spacing used on each command line must be used as
indicated. Table 3-2 defines the remote control commands
abbreviations. For detailed instructions on remotely control-
ling the FIREBERD 4000, refer to the FIREBERD 4000
Reference Manual.