27
(3) Manual release operation
Conduct the following when the brake is released manually. Do not turn on the brake power and
Never apply any load to the rod when releasing the brake manually.
1)
Remove the sealing bolts (2pcs) with M10 seal washer. (Figure1)
2)
Inset the bolts for manual release (M8X70L) attached with motor in two positions and tighten it into the
screw hole in the cover. (Figure2)
3)
The head surface of release screw hits the end. Keep tighten the bolts another 90
°
after it becomes heavy,
brake will be released.
【
Note
】
Do not tighten the bolts too much. Otherwise, the armature may deform and bolts or female screws at
cover may be damaged, which will lead to break failure.
4)
When setting back to regular braking condition, remove the bolts for manual release (M8X70L).
When these steps are completed, make sure works normally with motor.
【
Note
】
Securely tighten the sealing bolts. Otherwise, the sealing for brake cover may not perform efficiently,
water may enter the brake.
(
Figure1
)
(
Figure2
)
Sealing bolt
(
Hexagon nut
)
M10
(
with seal washer
)
Bolts for manual release
(
Phillips-round head screw attached
motor
)
M8 X 70