TCP Server Mode
a. Local TCP Port: The TCP Port of TRP-C34X that uses to listen to the requests coming
from Host Computers on Network in order to establish connection. The Host Computers
should contact this Port in order to establish connection with the TRP-C34X.
b. Click the Max Connection drop-down box to set Max connection options to 1 / 2 / 3 / 4.
c. TCP Alive Check Timeout (Default setting is 7 min).
d. Inactivity Timeout (Default setting is 0 ==> Disabled).
TCP Client Mode
a. Click the Connect Mode drop-down box to set “Startup”/ “Any character”.
b. Setting Destination IP address 1 and Port Number, allows TRP-C34X to connect actively
to the remote host whose address is set by this parameter.
c. Similarly Destination IP addresses 2 / 3 / 4, allows TRP-C34X to connect actively to the
remote hosts whose address is set by this parameter.
d. TCP Alive Check Timeout (Default setting is 7 min)
e. Inactivity Timeout (Default setting is 0 ==> Disabled).