![Truper SME-10X-3 Manual Download Page 19](http://html1.mh-extra.com/html/truper/sme-10x-3/sme-10x-3_manual_1176503019.webp)
Technical Data
3
ENGLISH
Power Requirements
The tool shall be grounded while in use to prevent an electric shock!
The saw shall be I stalled as close as possible of the main power supply. Check the power supply is the same voltage indicated in
the motor nameplate.
This device shall be grounded!
The power cables are codified with the following colors:
SME-10X-3
82” x 41” x 34” Base: 20” x 20”
10640
3 Hp
3450 RPM
Table Saw with Extension
60 Hz
Measurements
Code
Description
Motor
10”
Disc
Speed
Voltage
Current
Frequency
14 AWG x 3C with 221 °F Insulation Power
Conductors
Power cord grips used in this product: Type “Y”.
Build quality: Reinforced Insulation
Thermal insulation on motor winding: Class H
220 V
* Allowed to be used only if the extensions have a built-in overcurrent protection device.
AWG= American Wire Gauge. Reference: NMX-J-195-ANCE-2006
When using an extension cable, double check it is the gauge enough to transport the current the tool
will need. A lower caliber cable will cause voltage drops in the line, resulting in power loss and overheating of the motor.
The following table shows the right gauge to use depending on the cable length and the ampere capacity indicated in the
tool nameplate. When in doubt, use the next higher gauge.
GREEN GROUND
WHITE
LINE 1
BLACK
LINE 2
IP Grade
IP20
Class I
Insulation
12,8 A
WARNING
WARNING
CAUTION
WARNING
120 min work per 30 min rest. Daily Maximum 6 hours.
Work Cycle
From 0 and up to 10 A
From 10 and up to 13 A
From 13 and up to 15 A
From 15 and up to 20 A
18 AWG
16 AWG
14 AWG
8 AWG
16 AWG
14 AWG
12 AWG
6 AWG
3 (one grounded)
From 6 ft to 49 ft | Higher than 49 ft
Ampere
Capacity
Number of
Conductors
Extension Gauge
WARNING
WARNING
Avoid the risk of electric shock or severe injury. When the power cable gets damaged
it should only be replaced by the manufacturer or at a Authorized Service Center.
The build quality of the electric insulation is altered if spills or liquid gets into the tool while in use.
Do not expose to rain, liquids and/or dampness.
Before gaining access to the terminals all power sources should be disconnected.