![Truma Mover XT4 Operating And Installation Instructions Download Page 21](http://html.mh-extra.com/html/truma/mover-xt4/mover-xt4_operating-and-installation-instructions_1175933021.webp)
21
Technical data
Operating voltage
12 V DC
Power consumption
on average approx. 37 A up to a maximum of 150 A
Quiescent current consumption
< 80 mA (with plug / adapter inserted)
< 150 μA (plug / adapter disconnected or after 1 hour with
plug / adapter inserted)
Radio frequency
Class 2, 868 MHz
Speed
approximately 17 cm per second
(depending on weight and incline)
Weight
approx. 60 kg
Positive line fuse
150 A
Mover® XT4 range of use
Dual-axle caravans with a gross weight of up to 3100 kg
Subject to technical changes.
EU Declaration of Conformity
Product
Function:
Manoeuvring assistant
Type:
Mover® XT
Versions:
XT, XT2, XT L, XT4, HR XT, HR XT2, HR XT L,
HR
XT4
Manufacturer
Truma Gerätetechnik GmbH & Co. KG
Wernher-von-Braun-Str. 12,
85640 Putzbrunn, Germany
This declaration of conformity is issued under the sole re-
sponsibility of the manufacturer.
The product is in conformity with the relevant Union
harmonisation legislation:
Directive 2014/53/EU Radio
equipment
UN ECE R10
Electromagnetic compatibility of
vehicles
The following (harmonised) standards and other techni-
cal specifications were used:
EN 300 220-1 V3.1.1; EN 300 220-2 V3.1.1
EN 301 489-1 V1.9.2; EN 301 489-3 V1.6.1
EN 60950-1:2006/A2:2013
The KBA, 24932 Flensburg, Germany issued the type approval(s):
E1 10R-04 6968
Signed for and on behalf of:
Truma Gerätetechnik GmbH & Co. KG
Frank Oster
CEO
Putzbrunn, 22.06.2017