background image

7

EN

Read the safety instructions and operating instructions 

carefully before starting the appliance. 

Operating instructions can be viewed in offline mode 

with a mobile device and the  Truma App. Download the 

operating instructions when you have a WiFi connection and 

save them on your mobile device.

Before initial use, be sure to flush the entire water supply thor-

oughly with clear water. 

The materials of the appliance that come into contact 

with water are safe for drinking water (see Manu-

facturer’s Declaration, www.truma.com – Manufacturer’s 

Declaration)

Control panels

The control panels are described in separate operating 

instructions. 

The temperature setting on the control panel depends on per-

sonal heating requirements and the design of the vehicle, and 

must be determined individually.

Room temperature sensor

To measure the room temperature, an external room tempera-

ture sensor (2) is located in the vehicle. The position of the 

sensor is determined by the vehicle manufacturer depending 

on the vehicle model. More information can be found in the 

operating instructions for your vehicle.

2

Figure 2

Safety / drain valve

A.   FrostControl 

(Safety / drain valve with integral frost protection / optional in 

the UK version)

 FrostControl is a currentless safety / drain valve. When there 

is a danger of frost, it automatically drains the contents of 

the boiler through a drainage socket. If excessive pressure is 

present in the system, pressure will be automatically intermit-

tently equalized through the pressure relief valve.

a

b

c

d

Figure 3

a  = rotary switch position “On” 

b = pushbutton position “Closed”

c  = pushbutton position “Drain”

d = drainage socket (led outside through floor of vehicle)

Operating instructions

Heating mode

In heating mode

 the appliance automatically selects the 

required operating level according to the temperature differ-

ence between the temperature set on the control panel and 

the current room temperature. If the water container has been 

filled, the water is automatically heated as well. The water 

temperature depends on the selected operating mode and the 

heater output. 

All 3 energy selection options can be used for.

 

– In 

gas mode

 the appliance automatically selects the oper-

ating level that is required.

 

– In 

electric mode

 output of 900 W (3.9 A) or 1800 W (7.8 A) 

can be manually preselected in accordance with the fuse 

protection at the camp site. 

If more output is required (e.g. heating up or low outside 

temperatures) gas or mixed mode should be selected so 

that enough heating power is always available. 

 

– In 

mixed mode

 230 V   electric mode is preferred if the 

power requirement is only low (e.g. for maintaining the 

room temperature). The gas burner is not enabled until the 

power requirement is higher, and is the first to switch off 

during heat-up operations. 

Hot water mode

(with filled water container only)

Gas mode or 230 V   electric mode is used for hot water 

preparation. The water temperature can be set to 40 °C / 

ECO* or 60 °C / HOT*. 

* ECO, HOT only with control panel Truma CP plus.

 

– In 

gas mode

 the water is heated at the lowest burner set-

ting. Once the water temperature has been reached, the 

burner switches off.

 

– In 

electric mode

 output of 900 W (3.9 A) or 1800 W (7.8 A) 

can be manually selected in accordance with the fuse pro-

tection at the camp site.

Mixed mode

 is not possible. With this setting the appli-

ance automatically selects electric mode. If the 230 V   

power supply is disconnected or fails, the heater automatical-

ly switches over to gas mode.

Summary of Contents for Combi 2 E

Page 1: ...EN Operating instructions To be kept in the vehicle Combi E Page 02 ...

Page 2: ...al 10 Faults 11 Troubleshooting guide water supply 11 Accessories 11 Manufacturer s Warranty European Union 12 Combi E Geändert Ludsteck 2017 17 18 2 3 5 7 8 9 11 10 14 15 16 4 12 13 6 6 1 Figure 1 Symbols used Symbol indicates possible hazards Note containing information and tips Observe the ESD regulations Intended use Proper use The appliance is approved solely for installation and opera tion i...

Page 3: ... smoke Open windows and doors Evacuate all persons from the vehicle Shut off gas cylinders and or shut off the gas supply from the outside Have the entire gas system inspected and repaired by experts Do not put the gas system back into opera tion until it has been inspected and repaired Working on the appliance in the installation compartment Possible danger from electric shock or explosion as a r...

Page 4: ... relevant national regulations in Germany every 2 years The test must be confirmed on the respective test certificate G 607 Pressure regulating devices and hoses must be replaced with new ones no more than 10 years after their date of manufacture every 8 years if used commercially Inspect hose lines regularly and have them replaced if they are broken Safe operation The exhaust cowl must not be blo...

Page 5: ...le duct must be checked regularly particu larly at the end of long trips Also check the mounting of the appliance and the cowl Operation while driving For heating while driving the directive UN ECE R 122 for motor caravans and cara vans specifies a safety shut off device in order to prevent the uncontrolled escape of gas in the event of an accident The Truma MonoControl CS gas pressure regulator s...

Page 6: ...red this is possible in hot water mode In hot water mode the water is heated at the lowest burner setting Once the water temperature has been reached the burner switches off In heating mode the appliance automatically selects the required operating level according to the temperature dif ference between the temperature set on the control panel and the current room temperature If the boiler has been...

Page 7: ...nage socket led outside through floor of vehicle Operating instructions Heating mode In heating mode the appliance automatically selects the required operating level according to the temperature differ ence between the temperature set on the control panel and the current room temperature If the water container has been filled the water is automatically heated as well The water temperature depends ...

Page 8: ...al position a or b Filling the water Check whether the safety drain valve is closed see Closing the safety drain valve When the temperature at FrostControl is below approx 7 C first switch on the heater to warm the installation compartment and FrostControl After several minutes when the temperature at FrostControl is above 7 C the safety drain valve can be closed Switch on the power for the pump a...

Page 9: ...on for at least 30 minutes and no hot water may be removed The residual heat in the heat exchanger will heat the water up to 70 C Solar systems When a solar system is used EN 1648 stipulates that a battery with charge regulator or a voltage regulator output voltage 11 V 15 V alternating voltage ripple 1 2 Vss must be connected between the solar system and the heater at all times Otherwise the heat...

Page 10: ...s consumption Combi 2 E UK 160 g h Combi 4 E 160 335 g h Combi 6 E 160 460 g h Standby heat requirement all appliances Gas mode 8 6 g h measured in accordance with EN 15033 Additional information according to EN 624 Combi 2 E UK Qn 2 4 kW Hs 170 g h C13 I3 B P 30 Combi 4 E Qn 4 8 kW Hs 345 g h C13 I3 B P 30 Combi 6 E Qn 6 8 kW Hs 480 g h C13 I3 B P 30 Destination countries Combi 2 E UK GB IE Combi...

Page 11: ...ent for FrostControl The FrostControl can no longer be closed Temperature at FrostControl less than approx 7 C Switch heater on Without heater operation the FrostControl cannot be closed again until the temperature reaches ap prox 7 C Rotary switch is not set to Operation Turn the rotary switch of the FrostControl to Operation then press the pushbutton until it engages If these actions do not reme...

Page 12: ...2 Warranty exclusions No warranty claim shall be applicable under the following circumstances Improper unsuitable faulty or negligent use and any use that is not compliant with the intended purpose Improper installation assembly or commissioning contrary to operating or installation instructions Improper operation or operation contrary to operating or installation instructions particularly any dis...

Page 13: ...89 4617 2020 Telefax 49 0 89 4617 2159 service truma com www truma com EN Should problems occur please contact the Truma Service Centre or one of our authorised service partners see www truma com In order to avoid delays please have the unit model and serial number ready see type plate 34020 00851 00 11 2019 ...