background image

6

EN

Maintenance / Repairs / Cleaning

– The appliance may only be repaired and 

cleaned by an expert. 

– Maintenance, repairs and cleaning must not 

be done by children.

–  Combi E only:  

If this appliance’s power supply line is dam-
aged, it must be replaced by the manufac-
turer, the manufacturer’s Customer Service 
or a similarly qualified person so as to pre-
vent hazards

.

– In particular, the following will render war-

ranty and guarantee claims void and lead to 
exemption from liability claims:

– Modifications to the appliance (including 

accessories), 

– Modifications to the exhaust gas system 

and the cowl, 

– Using replacement and accessory parts 

other than original  Truma parts, 

– Failure to follow the installation and 

operating instructions. 

The appliance’s operating permit, and conse-
quently also the vehicle’s operating permit in 
some countries, are also rendered void.

– With a new Combi or if the appliance has not 

been used for some time, thoroughly rinse 
all hot / cold water hoses with drinking water 
before use.

Function description 

(Combi)

The liquid gas heater Combi is a warm-air heater with inte-

grated hot water boiler (10 litre volume). The burner is fan-

assisted, which ensures that operation is problem-free, even 

when on the move.

In 

heating mode,

 the heater can be used to heat both the 

room and water simultaneously. If only hot water is required, 

this is possible in 

hot water mode.

 

– In 

hot water mode, 

the water is heated at the lowest burner 

setting. Once the water temperature has been reached, the 

burner switches off.

 

In heating mode

 the appliance automatically selects the 

required operating level according to the temperature dif-

ference between the temperature set on the control panel 

and the current room temperature. If the boiler has been 

filled, the water is automatically heated as well. The water 

temperature depends on the selected operating mode and 

the heater output.

At a temperature of approximately 3 °C at the automatic 

 FrostControl safety / drain valve, the valve will open and drain 

the boiler. 

Function description

(Combi E)

(in conjunction with the  Truma CP plus control panel)

The liquid gas heater  Combi E is a warm-air heater with inte-

grated hot water boiler (10 litres volume). The burner is fan-

assisted, which ensures that operation is problem-free, even 

when on the move. The appliance also has heating elements 

for electrical operation. 

In 

heating mode,

 the heater can be used to heat both the 

room and water simultaneously. If only hot water is required, 

this is possible in 

hot water mode.

At a temperature of approximately 3 °C at the automatic 

 FrostControl safety / drain valve, the valve will open and 

drain the boiler.

3 different options are available for operating the appliance:

 

– only 

gas mode

 

Propane / Butane for autonomous use

 

– only 

electric mode

 

230 V   for stationary use on camp sites

 

– or

 

gas and electric mode — 

mixed mode 

possible only in heating mode.

Summary of Contents for Combi 2 E

Page 1: ...EN Operating instructions To be kept in the vehicle Combi E Page 02 ...

Page 2: ...al 10 Faults 11 Troubleshooting guide water supply 11 Accessories 11 Manufacturer s Warranty European Union 12 Combi E Geändert Ludsteck 2017 17 18 2 3 5 7 8 9 11 10 14 15 16 4 12 13 6 6 1 Figure 1 Symbols used Symbol indicates possible hazards Note containing information and tips Observe the ESD regulations Intended use Proper use The appliance is approved solely for installation and opera tion i...

Page 3: ... smoke Open windows and doors Evacuate all persons from the vehicle Shut off gas cylinders and or shut off the gas supply from the outside Have the entire gas system inspected and repaired by experts Do not put the gas system back into opera tion until it has been inspected and repaired Working on the appliance in the installation compartment Possible danger from electric shock or explosion as a r...

Page 4: ... relevant national regulations in Germany every 2 years The test must be confirmed on the respective test certificate G 607 Pressure regulating devices and hoses must be replaced with new ones no more than 10 years after their date of manufacture every 8 years if used commercially Inspect hose lines regularly and have them replaced if they are broken Safe operation The exhaust cowl must not be blo...

Page 5: ...le duct must be checked regularly particu larly at the end of long trips Also check the mounting of the appliance and the cowl Operation while driving For heating while driving the directive UN ECE R 122 for motor caravans and cara vans specifies a safety shut off device in order to prevent the uncontrolled escape of gas in the event of an accident The Truma MonoControl CS gas pressure regulator s...

Page 6: ...red this is possible in hot water mode In hot water mode the water is heated at the lowest burner setting Once the water temperature has been reached the burner switches off In heating mode the appliance automatically selects the required operating level according to the temperature dif ference between the temperature set on the control panel and the current room temperature If the boiler has been...

Page 7: ...nage socket led outside through floor of vehicle Operating instructions Heating mode In heating mode the appliance automatically selects the required operating level according to the temperature differ ence between the temperature set on the control panel and the current room temperature If the water container has been filled the water is automatically heated as well The water temperature depends ...

Page 8: ...al position a or b Filling the water Check whether the safety drain valve is closed see Closing the safety drain valve When the temperature at FrostControl is below approx 7 C first switch on the heater to warm the installation compartment and FrostControl After several minutes when the temperature at FrostControl is above 7 C the safety drain valve can be closed Switch on the power for the pump a...

Page 9: ...on for at least 30 minutes and no hot water may be removed The residual heat in the heat exchanger will heat the water up to 70 C Solar systems When a solar system is used EN 1648 stipulates that a battery with charge regulator or a voltage regulator output voltage 11 V 15 V alternating voltage ripple 1 2 Vss must be connected between the solar system and the heater at all times Otherwise the heat...

Page 10: ...s consumption Combi 2 E UK 160 g h Combi 4 E 160 335 g h Combi 6 E 160 460 g h Standby heat requirement all appliances Gas mode 8 6 g h measured in accordance with EN 15033 Additional information according to EN 624 Combi 2 E UK Qn 2 4 kW Hs 170 g h C13 I3 B P 30 Combi 4 E Qn 4 8 kW Hs 345 g h C13 I3 B P 30 Combi 6 E Qn 6 8 kW Hs 480 g h C13 I3 B P 30 Destination countries Combi 2 E UK GB IE Combi...

Page 11: ...ent for FrostControl The FrostControl can no longer be closed Temperature at FrostControl less than approx 7 C Switch heater on Without heater operation the FrostControl cannot be closed again until the temperature reaches ap prox 7 C Rotary switch is not set to Operation Turn the rotary switch of the FrostControl to Operation then press the pushbutton until it engages If these actions do not reme...

Page 12: ...2 Warranty exclusions No warranty claim shall be applicable under the following circumstances Improper unsuitable faulty or negligent use and any use that is not compliant with the intended purpose Improper installation assembly or commissioning contrary to operating or installation instructions Improper operation or operation contrary to operating or installation instructions particularly any dis...

Page 13: ...89 4617 2020 Telefax 49 0 89 4617 2159 service truma com www truma com EN Should problems occur please contact the Truma Service Centre or one of our authorised service partners see www truma com In order to avoid delays please have the unit model and serial number ready see type plate 34020 00851 00 11 2019 ...

Reviews: