10
EN
Overheating protection 230 V ( Combi E)
230 V heating mode has a mechanical overheating protec-
tion switch. If the 12 V power supply is interrupted, for
example during operation or during the after-run period, the
temperatures within the appliance could activate the over-
heating protection.
Figure 7
Resetting the overheating protection: Allow the heater to cool,
remove the connector cover and press the reset button.
After replacing the fuse and resetting the overheating
protection, the connection cover must be put back in
order to protect the appliance electronics against dripping
water.
Technical data
Determined in accordance with EN 624 or Truma test
conditions
Gas type
Liquefied gas (propane / butane)
Operating pressure
30 mbar (see type plate)
Water capacity
10 litres
Heating time from approx. 15 °C to approx. 60 °C
Boiler approx. 23 minutes (measured according to EN 15033)
boiler approx. 80 min.
Pump pressure
max. 2.8 bar (280 kPa)
System pressure
max. 4.5 bar (450 kPa)
Rated heat output
(automatic operating levels)
Gas mode
Combi 2 E UK:
2000 W
Combi 4 (E):
2000 W / 4000 W
Combi 6 (E):
2000 W / 4000 W / 6000 W
Electrical mode
Combi 2 E UK / 4 E / 6 E: 900 W / 1800 W
Mixed mode (gas and electric)
Combi 2 E UK /
Combi 4 E:
max. 3800 W
Combi 6 E:
max. 6900 W
Gas consumption
Combi 2 E UK:
160 g/h
Combi 4 (E):
160 – 335 g/h
Combi 6 (E):
160 – 460 g/h
Standby heat requirement (all appliances)
Gas mode 8.6 g/h (measured in accordance with EN 15033)
Additional information according to EN 624
Combi 2 E UK:
Q
n
= 2.4 kW (Hs), 170 g/h, C
13
, I
3 B/P(30)
Combi 4 (E):
Q
n
= 4.8 kW (Hs), 345 g/h, C
13
, I
3 B/P(30)
Combi 6 (E):
Q
n
= 6.8 kW (Hs), 480 g/h, C
13
, I
3 B/P(30)
Destination countries
Combi 2 E UK: GB, IE
Combi 4 (E) / 6 (E):
DE, AT, CH, DK, FI, NL, NO, SE, SK, CH, CZ, CY, BE, IT, RO,
GR, LI, LU, IS, PL, EE, LT, LV, MC, MT, PT, SI, HR, HU, FR, BG,
SM, TR, GB, IE
Air flow rate
(free-blowing without warm air duct)
Combi 2 E UK / Combi 4 (E) / Combi 6 (E):
with 3 warm air outlets max. 249 m³/h
with 4 warm air outlets max. 287 m³/h
Power consumption at 12 V
boiler
Combi 2 E UK /
Combi 4 (E):
1.2 – 6.5 A
Combi 6 (E):
1.4 – 6.5 A
Boiler heating maximum 0.5 A
Quiescent current approx. 0.001 A
Heating element – FrostControl (optional): maximum 0.4 A
Power consumption at 230 V
Combi 2 E UK / Combi 4 E / Combi 6 E
3.9 A (900 W) or 7.8 A (1800 W)
Protection type
IP 21
Weight
(without water)
Combi 2 E UK
Combi 4 E
Combi 6 E
–
Combi 4
Combi 6
Heater:
15.5 kg
14.4 kg
Heater with periphery:
16.0 kg
14.9 kg
0085
Dimensions
450 mm
510 mm
300
m
m
Figure 8
Subject to technical changes.
Disposal
The appliance must be disposed of in accordance with the ad-
ministrative regulations of the respective country in which it is
used. National regulations and laws (in Germany, for example,
the End-of-Life Vehicle Regulation) must be observed.