background image

3

EN

Improper use

 

– All other uses not listed under proper use are improper and 

therefore prohibited. This applies e.g. to installation and 

operation in: 

  Motor buses (vehicle class M2 and M3), 

•  Commercial vehicles (vehicle class N), 

•  Boats and other water vehicles, 

•  Hunting lodges, weekend homes or awnings.

 

– Installation in trailers and vehicles used to transport hazard-

ous goods is prohibited.

 

– It is prohibited to heat liquids other than drinking water (e.g. 

cleaning, descaling, disinfection and preserving agents).

 

– Defective appliances must not be used.

 

– Appliances that are not installed or used in accordance with 

the installation and operating instructions may not be used.

Safety instructions

For safe and proper use, carefully read, follow 
and keep for later use the operating instruc-
tions and other documents that are supplied 
with the product. The respective valid laws, 
directives and standards must be observed.

Not following the rules in the operating and 
installation instructions can result in serious 
material damage and serious risk to the health 
or life of persons. The appliance’s operator or 
user is solely responsible for such damage.

Only competent and trained staff (ex-
perts) are permitted to install and repair 

the  Truma product and to carry out the func-
tion test, at the same time observing the in-
stallation and operating instructions and the 
currently recognised technical regulations. 
Experts are persons who, based on their spe-
cialist instruction and training, their knowledge 
and experience with  Truma products and the 
relevant standards, can carry out the necessary 
work properly and identify potential hazards.

What must I do if I smell gas?

 

– Avoid ignition sources, e.g. extinguish all 

naked flames, do not actuate any electrical 
switches or use any mobile phones or radios 
in the vehicle, do not start the vehicle’s en-
gine, do not operate any appliances, do not 
smoke.

 

– Open windows and doors

 

– Evacuate all persons from the vehicle.

 

– Shut off gas cylinders and / or shut off the 

gas supply from the outside.

 

– Have the entire gas system inspected and 

repaired by experts.

 

– Do not put the gas system back into opera-

tion until it has been inspected and repaired!

Working on the appliance, in the 

installation compartment

Possible danger from electric shock or 
explosion as a result of escaping gas! 

 

– Before starting any work:

1. Switch off the appliance
2. Close off the gas supply
3. Disconnect the appliance from the power 
supply and mains (230 V  ) at all poles

Possible risk of cut injuries from sharp 
edges!

– Wear suitable protective gloves and goggles 

when carrying out all work.

A safe operating environment

– The appliance may be operated only with 

appropriate  Truma control panels and 
accessories.

 

– It is not permissible to operate the appliance 

without a warm air duct.

– Danger of toxic exhaust fumes. The heater’s 

exhaust can be toxic in enclosed spaces 
(e.g. garages, workshops, awnings). If the 
vehicle is parked in closed rooms:
• Shut off the fuel supply to the heater
• Deactivate the time switch
• Switch off the heater at the control panel.
• Switch off the heater via the  Truma App if a 

 Truma iNet Box is installed.

– If the cowl has been placed near or directly 

beneath a window that can be opened, the 
appliance must be equipped with an auto-
matic shut-off device in order to prevent 
 operation with the window open.

 

– Possible fire hazard from higher temperatures! 

• Never use heat-sensitive items (e.g. spray 

cans, candles) or flammable materials, liq-
uids gaseous substances or vapours near 
to the appliance, in the installation com-
partment or in the appliance itself 

• Never block the warm air vents of the 

warm air distributor or bring heat-sensitive 
objects or flammable materials, liquids, 
gaseous substances or vapours into or into 
the vicinity of the warm air distributor

• The openings for the circulated air intake, 

the installation compartment and the in-
stallation compartment itself must be kept 
free of obstacles so that the appliance does 
not overheat

Summary of Contents for Combi 2 E

Page 1: ...EN Operating instructions To be kept in the vehicle Combi E Page 02 ...

Page 2: ...al 10 Faults 11 Troubleshooting guide water supply 11 Accessories 11 Manufacturer s Warranty European Union 12 Combi E Geändert Ludsteck 2017 17 18 2 3 5 7 8 9 11 10 14 15 16 4 12 13 6 6 1 Figure 1 Symbols used Symbol indicates possible hazards Note containing information and tips Observe the ESD regulations Intended use Proper use The appliance is approved solely for installation and opera tion i...

Page 3: ... smoke Open windows and doors Evacuate all persons from the vehicle Shut off gas cylinders and or shut off the gas supply from the outside Have the entire gas system inspected and repaired by experts Do not put the gas system back into opera tion until it has been inspected and repaired Working on the appliance in the installation compartment Possible danger from electric shock or explosion as a r...

Page 4: ... relevant national regulations in Germany every 2 years The test must be confirmed on the respective test certificate G 607 Pressure regulating devices and hoses must be replaced with new ones no more than 10 years after their date of manufacture every 8 years if used commercially Inspect hose lines regularly and have them replaced if they are broken Safe operation The exhaust cowl must not be blo...

Page 5: ...le duct must be checked regularly particu larly at the end of long trips Also check the mounting of the appliance and the cowl Operation while driving For heating while driving the directive UN ECE R 122 for motor caravans and cara vans specifies a safety shut off device in order to prevent the uncontrolled escape of gas in the event of an accident The Truma MonoControl CS gas pressure regulator s...

Page 6: ...red this is possible in hot water mode In hot water mode the water is heated at the lowest burner setting Once the water temperature has been reached the burner switches off In heating mode the appliance automatically selects the required operating level according to the temperature dif ference between the temperature set on the control panel and the current room temperature If the boiler has been...

Page 7: ...nage socket led outside through floor of vehicle Operating instructions Heating mode In heating mode the appliance automatically selects the required operating level according to the temperature differ ence between the temperature set on the control panel and the current room temperature If the water container has been filled the water is automatically heated as well The water temperature depends ...

Page 8: ...al position a or b Filling the water Check whether the safety drain valve is closed see Closing the safety drain valve When the temperature at FrostControl is below approx 7 C first switch on the heater to warm the installation compartment and FrostControl After several minutes when the temperature at FrostControl is above 7 C the safety drain valve can be closed Switch on the power for the pump a...

Page 9: ...on for at least 30 minutes and no hot water may be removed The residual heat in the heat exchanger will heat the water up to 70 C Solar systems When a solar system is used EN 1648 stipulates that a battery with charge regulator or a voltage regulator output voltage 11 V 15 V alternating voltage ripple 1 2 Vss must be connected between the solar system and the heater at all times Otherwise the heat...

Page 10: ...s consumption Combi 2 E UK 160 g h Combi 4 E 160 335 g h Combi 6 E 160 460 g h Standby heat requirement all appliances Gas mode 8 6 g h measured in accordance with EN 15033 Additional information according to EN 624 Combi 2 E UK Qn 2 4 kW Hs 170 g h C13 I3 B P 30 Combi 4 E Qn 4 8 kW Hs 345 g h C13 I3 B P 30 Combi 6 E Qn 6 8 kW Hs 480 g h C13 I3 B P 30 Destination countries Combi 2 E UK GB IE Combi...

Page 11: ...ent for FrostControl The FrostControl can no longer be closed Temperature at FrostControl less than approx 7 C Switch heater on Without heater operation the FrostControl cannot be closed again until the temperature reaches ap prox 7 C Rotary switch is not set to Operation Turn the rotary switch of the FrostControl to Operation then press the pushbutton until it engages If these actions do not reme...

Page 12: ...2 Warranty exclusions No warranty claim shall be applicable under the following circumstances Improper unsuitable faulty or negligent use and any use that is not compliant with the intended purpose Improper installation assembly or commissioning contrary to operating or installation instructions Improper operation or operation contrary to operating or installation instructions particularly any dis...

Page 13: ...89 4617 2020 Telefax 49 0 89 4617 2159 service truma com www truma com EN Should problems occur please contact the Truma Service Centre or one of our authorised service partners see www truma com In order to avoid delays please have the unit model and serial number ready see type plate 34020 00851 00 11 2019 ...

Reviews: