CAPACITIVE TOUCH SERIES

OPERATION INSTRUCTION

ON-OFF VALVE /COMPRESSOR CONTROL

Thermostat acquires the room temperature via its 
integrated sensor and maintains the set-point by 
simple on-off output.

POWER ON OR OFF

By pressing POWER button    

   

INCREASE / DECREASE

In the ON state, press UP      or       

     DOWN to increase or decrease 

the setting parameters.

FAN OPERATION

Fan  can  be  selected  as  manual  or  automatic  3-speed  operation.  In  manual 

mode,  the  fan  will  be  switched  to  the  selected  speed  via  control  output 

Gh,Gm,Gl (by pressing FAN button       ). In automatic mode, the fan speed will 

set-point. When room temperature reaches set-point, valve will be closed and 

changed to low speed instead of turning OFF via ISU mode)"

HEAT/COOL/VENT

Pressing the MODE button         to select heat 
         cool         or ventilation          mode.

TEMPERATURE DISPLAY

Both the room temperature and the set-point 
are displayed.

COMFORT MODE

In the comfort mode, the set point can be
changed by pressing UP      or DOWN      buttons. 

and manual heat/cool changeover.

KEY LOCK

The default status of “Key lock” is all keys available and it can be changed in 
ISU  mode.  Key  lock  function  includes  the  following  settings:  All  keys  are 
available  (Default)  Mode  button  is  locked  out.  Fan  and  Mode  button  are 
locked out. All buttons are locked.

ENERGY SAVING MODE

By pressing MODE button        for 3 seconds can activate the energy saving mode with      icon appearing on the screen. If energy saving 

is activated by button pressed, pressing POWER      button will stop energy saving mode. For heating mode, if energy saving function is 

enabled, the set-point will be changed to remote setback heating set-point. The range of remote setback heating set-point is from 10 °C 

to 21 °C and default value is 18 °C. The value can be changed in ISU mode with step of 1 °C . For cooling mode, if energy saving function 

is enabled, the set-point will be changed to remote setback cooling set-point. The range of remote setback cooling set-point is from 22°C 

to 32°C and default value is 26 °C. The value can be changed in ISU mode with step of 1 °C .

FREEZE PROTECTION MODE

Freeze  protection  can  be  disable(default)  or 
enabled  via  ISU  mode.  If  freeze  protection  is 
enabled(  it  is  not  available  in  cooling  only 
application) and thermostat is in OFF mode while 
the  room  temperature  is  below  6  °C  ,  the 
thermostat  will  open  heating  device  before  the 
temperature rises to 8 °C

TIME SETTING

In ON/OFF states, press       and        for 5 seconds, the time area           will 
be flashing, press      to select minutes, hours or week, then press       or       
to adjust the relevant time, press         to confirm.

TO SELECT MANUAL AND PROGRAMMABLE

In the thermostat ON status, Press and hold         and       for more than 5 
seconds, the icon of         or        will be flashing, press       to select 
manual       or programmable         and press         to confirm.

ADJUSTING OF WEEKLY PROGRAMMABLE

After selected programmable mode, press         for more than 5 seconds enter into program schedule setting then press           to 

select setting item of periods, time and temp. Press        or          to adjust the relevant value, press           to confirm. The program 

schedule is a weekly (7days) cycle, it can be selected for 5+2 days, 6+1 days or 7 days. 5+2 is 5 workdays plus 2 days holiday a week, 

6+1 is for 6 workdays plus 1 day holiday a week, 7 is for 7 workdays a week. There’s 6 periods for workdays and 2 periods for 

holidays. 

Setting sequence when enter program setting

Workdays 1st period time adjusting -> temperature adjusting -> 2nd period time adjusting -> temperature adjusting……6th period time 

adjusting -> temperature adjusting -> holidays 1st period time adjusting -> temperature adjusting -> 2nd period time adjusting  -> 

temperature adjusting

3

Summary of Contents for TX1000 Series

Page 1: ...e sensor key card can be chosen as per site requirements FEATURES Modern touch pad design residential buildings Applicable for 2 pipe FCU cooling heating Simple on off valve or compressor Black LCD an...

Page 2: ...f valve or compressor Suitable Valve 2 line 3 line valve Relative Humidity 10 90 Installed on 75mm x 75mm box ORDERING PART NUMBERS TX1000 OF220 V21CE 85 240VAC 2 PIPE SINGLE STAGE 2 PIPE SINGLE STAGE...

Page 3: ...ault value is 18 C The value can be changed in ISU mode with step of 1 C For cooling mode if energy saving function is enabled the set point will be changed to remote setback cooling set point The ran...

Page 4: ...ILABLE DEFAULT 1 MODE BUTTON IS LOCKED OUT 2 FAN AND MODE BUTTON ARE LOCKED OUT 3 ALL BUTTONS ARE LOCKED 5 REMOTE SETBACK ENABLE METHOD NO HOTEL CARD NO NC HOTEL CARD NC BU BUTTON DEFAULT 6 FREEZE PRO...

Page 5: ...OWER OFF WHILE ELECTRIFIED THE THERMOSTAT WILL BE OFF SU ON USER SETTING WILL BE KEPT WHEN POWER OFF WHILE ELECTRIFIED THE THERMOSTAT WILL BE ON DEFAULT IS OF 21 22 23 24 25 26 20 BACK LIGHT SETTINGS...

Page 6: ...PRESSOR OPEN 6 VALVE COMPRESSOR CLOSE 7 COM FOR EXTERNAL SENSOR 8 NEUTRAL IN 9 L FM FH FL NO NC COM N AI EXTERNAL SENSOR TERMINALS NO 1 LIVE IN 3 MEDIUM SPEED FAN HIGH SPEED FAN 4 LOW SPEED FAN 2 DESC...

Page 7: ...n Wait five minutes for the cooling system to respond The Mode button does not work Check whether the Fan mode is set to Auto Check whether the heating or cooling system works well Check whether the k...

Reviews: