CAPACITIVE TOUCH  SERIES

9 TERMINAL POWER BOX

*wiring is subject to change without notice based on addons

PRODUCT DIMENSION

6

NOTE:

♦ The thermostat is high voltage input, please do wiring with technician.

♦ If the thermostat was burned by accidently, please do not wiring it again by yourself, try to check it with a professional technician or contact    
with our manufacturer.

NO

1

LIVE IN

3

MEDIUM SPEED FAN

HIGH SPEED FAN 

4

LOW SPEED FAN  

2

DESCRIPTION

5

VALVE/COMPRESSOR OPEN

6

VALVE/COMPRESSOR CLOSE

7

COM FOR EXTERNAL SENSOR 

8

NEUTRAL IN 

9

L

FM

FH

FL

NO

NC

COM

N

AI

EXTERNAL SENSOR

TERMINALS

NO

1

LIVE IN

3

MEDIUM SPEED FAN

HIGH SPEED FAN 

4

LOW SPEED FAN  

2

DESCRIPTION

5

VALVE/COMPRESSOR OPEN

6

VALVE/COMPRESSOR CLOSE

7

COM FOR KEY CARD

8

NEUTRAL IN 

9

L

FM

FH

FL

NO

NC

COM

N

DI

EXTERNAL SENSOR

TERMINALS

NO

1

24V ACTIVE

3

HIGH SPEED FAN

220V LINE FOR 220V FAN 

4

MEDIUM SPEED FAN  

2

DESCRIPTION

5

LOW SPEED FAN

6

24V NEUTRAL

7

8

VALVE/COMPRESSOR OPEN

VALVE/COMPRESSOR CLOSE

9

R

FH

LINE

FM

FL

C

NC

NO

TERMINALS

WIRING DIAGRAM

TX1000OF220-V21CE

Fan

85-240VAC

TX1000OF220-V21CK

Fan

85-240VAC

TX1000OF024-V21C

Fan

24VAC

Summary of Contents for TX1000 Series

Page 1: ...e sensor key card can be chosen as per site requirements FEATURES Modern touch pad design residential buildings Applicable for 2 pipe FCU cooling heating Simple on off valve or compressor Black LCD an...

Page 2: ...f valve or compressor Suitable Valve 2 line 3 line valve Relative Humidity 10 90 Installed on 75mm x 75mm box ORDERING PART NUMBERS TX1000 OF220 V21CE 85 240VAC 2 PIPE SINGLE STAGE 2 PIPE SINGLE STAGE...

Page 3: ...ault value is 18 C The value can be changed in ISU mode with step of 1 C For cooling mode if energy saving function is enabled the set point will be changed to remote setback cooling set point The ran...

Page 4: ...ILABLE DEFAULT 1 MODE BUTTON IS LOCKED OUT 2 FAN AND MODE BUTTON ARE LOCKED OUT 3 ALL BUTTONS ARE LOCKED 5 REMOTE SETBACK ENABLE METHOD NO HOTEL CARD NO NC HOTEL CARD NC BU BUTTON DEFAULT 6 FREEZE PRO...

Page 5: ...OWER OFF WHILE ELECTRIFIED THE THERMOSTAT WILL BE OFF SU ON USER SETTING WILL BE KEPT WHEN POWER OFF WHILE ELECTRIFIED THE THERMOSTAT WILL BE ON DEFAULT IS OF 21 22 23 24 25 26 20 BACK LIGHT SETTINGS...

Page 6: ...PRESSOR OPEN 6 VALVE COMPRESSOR CLOSE 7 COM FOR EXTERNAL SENSOR 8 NEUTRAL IN 9 L FM FH FL NO NC COM N AI EXTERNAL SENSOR TERMINALS NO 1 LIVE IN 3 MEDIUM SPEED FAN HIGH SPEED FAN 4 LOW SPEED FAN 2 DESC...

Page 7: ...n Wait five minutes for the cooling system to respond The Mode button does not work Check whether the Fan mode is set to Auto Check whether the heating or cooling system works well Check whether the k...

Reviews: