background image

CAPACITIVE TOUCH SERIES

ADJUSTING OF WEEKLY 
PROGRAMMABLE

MON

TUE

WED

THU

FRI

SAT

SUN

IN PROGRAMMABLE MODE, SET-POINT
AND TIME COULD NOT BE ADJUSTED

06:00AM

08:00AM

11:30AM

12:30PM

17:00PM

22:00PM

06:00AM

23:00PM

1

2

3

4

5

6

1

2

PERIODS

WORKDAYS

WEEKEND

SYMPOLS

DEFAULT TIME DEFAULT TEMP.

26  0C

26  0C

26  0C

26  0C

26  0C

26  0C

26  0C

26  0C

PERIODS 
DESCRIPTION

1

ST

 PERIOD, WAKE UP

2

ND

 PERIOD, LEAVE

3

RD

 PERIOD, 

BACK FOR LUNCH

4

TH

 PERIOD, LEAVE 

5

TH

 PERIOD, 

BACK FOR DINNER

6

TH

 PERIOD, WAKE UP

SYMPOLS

DESCRIPTION

ISU CODE 

DESCRIPTION 

POSSIBLE OPTIONS

1

SYSTEM TYPE

0 HEAT ONLY

1 COOL ONLY

2 TWO PIPES 1H1C MANUAL(DEFAULT)

2

TEMPERATURE UNIT 

F  :  ° F

C  :  ° C(DEFAULT)

3

FAN CONTROL TYPE 

AO :  AUTO  ONLY

CO :  CONSTANT  ONLY

BO :  BOTH(DEFAULT)

4

KEYPAD LOCK OUT 

0  :  ALL KEYS ARE AVAILABLE (DEFAULT)

1  :  MODE BUTTON IS LOCKED OUT

2  :  FAN AND MODE BUTTON ARE LOCKED OUT

3  :  ALL BUTTONS ARE LOCKED

5

REMOTE SETBACK ENABLE METHOD 

NO :   HOTEL CARD NO

NC :   HOTEL CARD NC

BU :   BUTTON (DEFAULT)

6

FREEZE PROTECTION

OF :   DISABLED(DEFAULT)

ON :    ENABLED

7

DISPLAY TEMP. ADJUSTMENT 

-90C~+90C~(-90F~+90F)DEFAULT IS 00C/00F

8

REMOTE SETBACK HEATING SET-POINT

RANGE 10-21°C DEFAULT 18 ° C(RANGE 50-70°F

DEFAULT 64°F)

9

REMOTE SETBACK COOLING SET-POINT 

RANGE 22-32°C DEFAULT 26 ° C(RANGE 72-90°F

DEFAULT 79°F)

4

SETUP FUNCTION SETTINGS AND OPTIONS

a.  Press        and        key for 5 seconds to enter ISU setting mode, the ISU code will be flashing. 

b. Press         or            to select the setting items from 1-26.

c. Press         and the values of selected item will be flashing with icon      on,

  Press        and          revise the values of the setting items, press          to confirm.

If you want to revise the other setting items, please repeat above step b. and c. while setting, press        to exit, the setting items 

and values as below form shown.

Summary of Contents for TX1000 Series

Page 1: ...e sensor key card can be chosen as per site requirements FEATURES Modern touch pad design residential buildings Applicable for 2 pipe FCU cooling heating Simple on off valve or compressor Black LCD an...

Page 2: ...f valve or compressor Suitable Valve 2 line 3 line valve Relative Humidity 10 90 Installed on 75mm x 75mm box ORDERING PART NUMBERS TX1000 OF220 V21CE 85 240VAC 2 PIPE SINGLE STAGE 2 PIPE SINGLE STAGE...

Page 3: ...ault value is 18 C The value can be changed in ISU mode with step of 1 C For cooling mode if energy saving function is enabled the set point will be changed to remote setback cooling set point The ran...

Page 4: ...ILABLE DEFAULT 1 MODE BUTTON IS LOCKED OUT 2 FAN AND MODE BUTTON ARE LOCKED OUT 3 ALL BUTTONS ARE LOCKED 5 REMOTE SETBACK ENABLE METHOD NO HOTEL CARD NO NC HOTEL CARD NC BU BUTTON DEFAULT 6 FREEZE PRO...

Page 5: ...OWER OFF WHILE ELECTRIFIED THE THERMOSTAT WILL BE OFF SU ON USER SETTING WILL BE KEPT WHEN POWER OFF WHILE ELECTRIFIED THE THERMOSTAT WILL BE ON DEFAULT IS OF 21 22 23 24 25 26 20 BACK LIGHT SETTINGS...

Page 6: ...PRESSOR OPEN 6 VALVE COMPRESSOR CLOSE 7 COM FOR EXTERNAL SENSOR 8 NEUTRAL IN 9 L FM FH FL NO NC COM N AI EXTERNAL SENSOR TERMINALS NO 1 LIVE IN 3 MEDIUM SPEED FAN HIGH SPEED FAN 4 LOW SPEED FAN 2 DESC...

Page 7: ...n Wait five minutes for the cooling system to respond The Mode button does not work Check whether the Fan mode is set to Auto Check whether the heating or cooling system works well Check whether the k...