Mask with welding screening black glass.
Operations manual
This product is in accordance with the relevant EC
Directives
Electrical Connection Warning
This machine MUST be earthed. This welder
must be connected to a 230 V (50 Hz)
supply, having a rated capacity of greater than
12 amps.
A 13 amp (BS1363) plug is NOT supplied for
this device. Connect the three core mains leads to a suitably
fused supply through an isolator and heavy duty plug.
UK only: Ensure the unit is correctly earthed via a three pin
plug.
1. Connect the green/yellow earth wire to the earth terminal
‘E’.
2. Connect the brown live wire to live terminal ‘L’.
3. Connect the blue neutral wire to the neutral terminal ‘N’.
4. After wiring, check that there are no bare wires, that all
wires have been correctly connected, that the cable
external insulation extends beyond the cable restraint and
that the restraint is tight.
Figure 1 UK plug wiring