True North TN10 Installation And Operating Instructions Manual Download Page 9

5055.549-A

TN10 NA 080617-28

9

Do not burn anything but cord wood.  Other fuels, eg.  charcoal, can produce large amounts of carbon 
 monoxide, a  tasteless, odorless gas that can kill.  Under no  circumstances should you attempt to barbecue in 
this heater.

How  to Test Your Wood

Add a large piece of wood to the stove when it has a good large bed of coals.  It is dry if it is burning on more 
than one side within one minute.  It is damp if it turns black and lights within three minutes.  If it sizzles, hisses 
and blackens without igniting in five minutes it is soaked and should not be burned.

Lighting a Fire

Remove the retaining clip on the front of the baffle before lighting for the first time.

1.  Move air control lever to the left-most position  (maximum firing rate) and open door.  

2.  Place crumpled newspaper in the centre of the heater and crisscross with several pieces of dry kindling.  

Add a few small pieces of dry wood on top. 

3.  Ignite the paper and leave the door ajar approximately 1/2"(13mm) - 1"(25mm) until the wood kindling is 

fully engulfed in flame. 

4.  After the kindling is fully engulfed add a few small logs. Close door. 

5.  Begin normal operation after a good coal base exists and wood has charred.

Normal Operation

WARNING:  This wood heater has a manufacturer-set minimum low burn rate that must not be altered. 
It is against federal regulations to alter this setting or otherwise operate this wood heater in a manner 
inconsistent with the operating instructions in this manual.

1.  Set air control to a desired setting. If smoke pours down across the glass (waterfall effect) this indicates 

you have shut the control down too soon or you are using too low a setting. The wide range control panel 
makes finding the desired setting for your application easy. As every home's heating needs vary (ie. 
insulation, windows, climate, etc.) the proper setting can only be found by trial and error and should be 
noted for future burns. 

2.  To refuel, adjust air control to high, and give the fire time to brighten. Open the door slowly, this will pre-

vent back puffing. 

3.  Use wood of different shape, diameter and length (up to 14" (355mm)). Load your wood and try to place 

the logs so that the air can flow between them. Always use dry wood. 

4.  Do not load fuel to a height or in such a manner that would be hazardous when opening the door. 

5.  For extended or overnight burns, unsplit logs are preferred. Remember to char the wood completely on 

maximum setting before adjusting air control for overnight burn.

Summary of Contents for TN10

Page 1: ...restrictions and installation inspection requirements in your area IMPORTANT THESE INSTRUCTIONS ARE TO REMAIN WITH THE HOMEOWNER SAVE THESE INSTRUCTIONS MODEL TN10 SERIAL TESTED and LISTED to CAN ULC...

Page 2: ...26 Rating label location 26 HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS WARNING PLEASE SAVE THESE INSTRUCTIONS This manual describes the installatio...

Page 3: ...s the energy required to vaporize the water in the fuel 3 The range of BTU outputs is based on efficiency using CSA B415 Performance testing of solid fuel burning heating appliances and burn rates fro...

Page 4: ...pe requires only light pressure to seal This will prolong seal life It is important that the door seal be main tained in good condition Periodically inspect seals and replace if necessary Follow instr...

Page 5: ...excessive corrosion burned out sections and exces sive warping Weekly Firebrick Visual for cracking Door Gasket sagging placement damage Monthly Brick rail tabs and brick rails Back side of air wash c...

Page 6: ...he air inlet can be turned down substantially without excessive smoke generation Wood coals create very little creosote producing smoke 2 The cooler the surface over which the wood smoke is passing th...

Page 7: ...imney Fire Have a fire extinguisher handy Contact your local municipal or state provincial fire authority for further information on how to handle a chimney fire It is most important that you have a c...

Page 8: ...natural wood only Higher efficiency and lower emissions generally result when burning air dried seasoned hardwoods as compared to softwoods or to green or freshly cut hardwoods Wood should be properl...

Page 9: ...eration after a good coal base exists and wood has charred Normal Operation WARNING This wood heater has a manufacturer set minimum low burn rate that must not be altered It is against federal regulat...

Page 10: ...uring of the Paint Finish To achieve the best finish the paint on your stove must be baked on with small fires When burning your stove for the first 2 3 times it is very important that the room be wel...

Page 11: ...ly after the following conditions have been met DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE DO NOT INSTALL IN A SLEEPING ROOM THIS ROOM HEATER MUST BE CONNECTED TO 1 A CHIMNEY...

Page 12: ...proval U S NFPA 211 or CAN CSA B365 For for close clearances use a listed double wall connector See Figure 2 Double Wall Connector 2 Mobile Home installation must use listed double wall connector For...

Page 13: ...2 51 mm beyond each side Securing Bracket Installation These will be needed to anchor the stove in a mobile home installation and are recommended when installing combustion air to prevent move ment of...

Page 14: ...d location will not interfere with floor joists ceiling joists or rafters before proceeding further 4 As per the chimney manufacturer s instructions Cut a hole in the ceiling and roof to suit the chim...

Page 15: ...ure specifcations for distance between vent termination heigth and chimney at roof line Also consult local building regulations The chimney may incorporate an offset To do this safely all sections of...

Page 16: ...himney flue serving another appliance Minimum system height is 12 feet 3 0 m measured from top of appliance Fireclay Flue Liner Concrete Cap Chimney Approved Through Wall Installation 36 915mm Minimum...

Page 17: ...DS OF MAINTAINING VAPOUR BARRIER System A Minimum 3 5 in 90 mm thick brick masonry wall framed into combustible wall with a minimum of 12 in 305 mm brick separation from clay liner to combustibles Fir...

Page 18: ...ventilated air channels each 1 25 4 mm construction of sheet steel Chimney connector Masonry chimney constructed to NFPA 211 Chimney flue Minimum chimney clearance from masonry to sheet steel support...

Page 19: ...66 m or as per chimney manufacturers roof clearances whichever is greater NOTE Longer chimney lengths and different pitch flashings may be used Install all components to the connector or chimney manu...

Page 20: ...drill a corresponding hole in the closest exterior wall Install an approved 3 76mm inlet vent cap Attach the outside air adapter to the underside of the stove Connect the adapter to the inlet vent ca...

Page 21: ...rse the process to replace the baffle assembly Installation 1 Insert one half of baffle board above the two back baffle tubes inside the firebox slide over to the right and allow to rest on the baffle...

Page 22: ...10 2 Using the same 4 screws place the blower into the opening in the rear shield with the blower outlet pointing up Figure 11 3 Tighten the screws Blower Operation Proper blower speed matched with a...

Page 23: ...s Install each side brick insert the brick under the retaining flange near the front of the baffle air box on each side of the firebox and then slide the brick to the back of the unit Next install 3 f...

Page 24: ...See 1 2 3 above Low Heat Output 1 Wood is wet Use dry wood 2 Fire too small Build a larger fire 3 Draft too low Chimney plugged or restricted inspect and clean Won t Burn Overnight 1 Air control is s...

Page 25: ...2pcs TN10 RP50987625 3 Baffle Tube Set 4pcs TN10 RP50001105 4 Door Casting Assy c w Handle TRNO DRBK 5 Door Gasket TN19 DGKIT 6 Replacement Glass c w gasket TRNO 7025 7 Glass Clamps 4 pcs TRNO 7608 8...

Page 26: ...LES OFFICIELS DE LA CONSTRUCTION OU DE SERVICE D INCENDIE POUR DES INFORMATIONS QUANT AUX RES TRICTIONS PERMIS D INSTALLATION ET INSPECTIONS DANS VOTRE R GION NE RELIEZ PAS CET APPAREIL UN CONDUIT DE...

Page 27: ...5055 549 A TN10 NA 080617 28 27...

Page 28: ...Web site www truenorthstoves com 2975 Allenby Rd Duncan BC V9l 6V8 2017 Copyright Pacific Energy Fireplace Products LTD Reproduction adaptation or translation without prior written permission is proh...

Reviews: