Double-Wall Connector
•
Use a listed double-wall connector.
•
Install all components to the chimney connector manufacturer's installation requirements.
Single-Wall Connector
Smoke pipe (chimney connector) must be:
•
As short and straight as possible, use 6"(150mm) diameter, minimum 24 gauge black pipe, that is clean
and in new condition.
•
Secured at every joint and collar with 3 sheet metal screws.
•
Installed with the crimped or male ends pointing down. This will carry any liquid creosote or condensation
back into the stove.
•
The Smoke pipe/chimney connector shall not pass through an attic, roof space, closet or similar
concealed space, or a floor, or ceiling. Where passage through a wall, or partition of combustible material
is desired, the installation shall conform to CAN/CSA-B365, INSTALLATION CODE FOR SOLID-FUEL-
BURNING APPLIANCES AND EQUIPMENT or NFPA 211 STANDARD FOR CHIMNEYS, FIREPLACES AND
SOLID FUEL BURNING APPLIANCES
Procedure
1. Position stove and floor protection (with hole for combustion air if required) in accordance with the
clearances as stated on the label and in Figure 2., and Figure 3 or Figure 4.
2. Mark the position for the hole in the ceiling and roof by using a string and plumb-bob.
3. Check that the intended location will not interfere with floor joists, ceiling joists or rafters before
proceeding further.
4. As per the chimney manufacturer's instructions;
•
Cut a hole in the ceiling and roof to suit the chimney system and frame in the sides. The chimney
support is mounted to the framing. If a roof or ceiling support is used in the installation, you will find the
chimney manufacturer's complete instructions packed with the roof support.
•
Assemble the chimney sections so the finished length is resting on the support and protruding through
the roof. Install the radiation shield. Avoid having chimney joints between ceiling and roof.
•
Assemble flashing and storm collar and be sure to secure the flashing and seal with the appropriate
sealant. Attach rain cap and check flashing for leaks.
5. If double-wall connector pipe is to be connected between the stove and the listed insulated chimney,
install all components to the pipe manufacturer's installation requirements.
6. If smoke pipe is being used to connect between the stove and the listed insulated chimney,
•
Install the smoke pipe (chimney connector), crimped edge of the pipe down and inside the stove collar.
Use holes provided in collar to secure pipe with three screws.
•
Install the remaining lengths of pipe, one on top of the other to the finished height of the listed insulated
chimney adapter and secure to each other. A slip-section will make attaching the smoke pipe to the
chimney system adapter easier.