1.  Burn only dry and well seasoned cord wood. The denser or heavier the wood when dry, the greater its 

heat value.  This is why hardwoods are generally preferred. Green or wet wood will cause a rapid buildup 
of creosote. If you feel it is necessary to burn wet or unseasoned wood, do so only with the air inlet set 
open enough to maintain a good strong fire and fairly high chimney temperatures. Do not attempt to burn 
overnight using green wood or wet wood.  Wet wood can cause up to 25% drop in heater output, as well 
as contributing significantly to creosote buildup. 

2.  Remove ashes frequently. Embers can roll out the door and create a fire hazard. Maintain a 1"(25mm) 

minimum ash base. 

3.  If glass becomes darkened through slow burning or poor wood, it can readily be cleaned with fireplace 

glass cleaner when stove is cold. Never scrape with an object that might scratch the glass. The type and 
amount of deposit on the glass is a good indication of the flue pipe and chimney buildup. A light brown 
dusty deposit that is easily wiped off usually indicates good combustion and dry, well-seasoned wood and 
therefore relatively clean pipes and chimney. On the other hand, a black greasy deposit that is difficult to 
remove is a result of wet and green wood and too slow a burning rate. This heavy deposit is building up at 
least as quickly in the chimney. 
  

4.  DOOR GASKETS - The gasket used for the True North (5/8"(16mm) medium density fiberglass rope) 

requires only light pressure to seal.  This will prolong seal life. It is important that the door seal be main-
tained in good condition.  Periodically inspect seals and replace if necessary. Follow instructions included 
in the TN19.DGKIT kit obtainable from your nearest True North dealer. 

5.  DOOR GLASS - Do not slam loading door or otherwise impact glass. When closing door, make sure that 

no logs protrude to impact the glass. If the glass gets cracked or broken, it must be replaced before using 
the stove. Replacement glass can be obtained from your dealer. Use 9-1/4"(235mm) x 13-1/4"(337mm) x 
5 mm. Ceramic glass only.  Do not substitute with any other type. 

• 

-To remove broken glass, undo the four retaining screws and remove clamps, noting  position for 
 re-assembly.  Remove all particles of glass. Be careful as they are very sharp. Install new glass complete 
with gasket. Replace clamps and screws. 

CAUTION: 
  
 

- do not overtighten, tighten screws very carefully 

 

- do not clean glass when hot 

 

- do not use abrasive cleaners on glass 

6.  The area where boost combustion air enters the firebox must be kept clear of excessive ash buildup 

which will block air flow. This area is at the front of the firebox. 

7.  Do not store wood within heater installation  clearances, or within the space required for fuel loading 

and ash  removal. Keep the area around the heater clean and free of loose combustibles, furniture, 
newspapers, etc.

 Safety and Maintenance 

WARNING: Never use chemicals or any other  volatile liquid to start a fire.  Do not burn garbage, or 
 flammable fluids such as gasoline, naptha, or engine oil.  

WARNING: ONLY USE MATERIALS SUPPLIED BY MANUFACTURER WHEN DOING MAINTENANCE OR 
REPLACEMENTS.

Summary of Contents for TN10

Page 1: ...restrictions and installation inspection requirements in your area IMPORTANT THESE INSTRUCTIONS ARE TO REMAIN WITH THE HOMEOWNER SAVE THESE INSTRUCTIONS MODEL TN10 SERIAL TESTED and LISTED to CAN ULC...

Page 2: ...26 Rating label location 26 HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS WARNING PLEASE SAVE THESE INSTRUCTIONS This manual describes the installatio...

Page 3: ...s the energy required to vaporize the water in the fuel 3 The range of BTU outputs is based on efficiency using CSA B415 Performance testing of solid fuel burning heating appliances and burn rates fro...

Page 4: ...pe requires only light pressure to seal This will prolong seal life It is important that the door seal be main tained in good condition Periodically inspect seals and replace if necessary Follow instr...

Page 5: ...excessive corrosion burned out sections and exces sive warping Weekly Firebrick Visual for cracking Door Gasket sagging placement damage Monthly Brick rail tabs and brick rails Back side of air wash c...

Page 6: ...he air inlet can be turned down substantially without excessive smoke generation Wood coals create very little creosote producing smoke 2 The cooler the surface over which the wood smoke is passing th...

Page 7: ...imney Fire Have a fire extinguisher handy Contact your local municipal or state provincial fire authority for further information on how to handle a chimney fire It is most important that you have a c...

Page 8: ...natural wood only Higher efficiency and lower emissions generally result when burning air dried seasoned hardwoods as compared to softwoods or to green or freshly cut hardwoods Wood should be properl...

Page 9: ...eration after a good coal base exists and wood has charred Normal Operation WARNING This wood heater has a manufacturer set minimum low burn rate that must not be altered It is against federal regulat...

Page 10: ...uring of the Paint Finish To achieve the best finish the paint on your stove must be baked on with small fires When burning your stove for the first 2 3 times it is very important that the room be wel...

Page 11: ...ly after the following conditions have been met DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE DO NOT INSTALL IN A SLEEPING ROOM THIS ROOM HEATER MUST BE CONNECTED TO 1 A CHIMNEY...

Page 12: ...proval U S NFPA 211 or CAN CSA B365 For for close clearances use a listed double wall connector See Figure 2 Double Wall Connector 2 Mobile Home installation must use listed double wall connector For...

Page 13: ...2 51 mm beyond each side Securing Bracket Installation These will be needed to anchor the stove in a mobile home installation and are recommended when installing combustion air to prevent move ment of...

Page 14: ...d location will not interfere with floor joists ceiling joists or rafters before proceeding further 4 As per the chimney manufacturer s instructions Cut a hole in the ceiling and roof to suit the chim...

Page 15: ...ure specifcations for distance between vent termination heigth and chimney at roof line Also consult local building regulations The chimney may incorporate an offset To do this safely all sections of...

Page 16: ...himney flue serving another appliance Minimum system height is 12 feet 3 0 m measured from top of appliance Fireclay Flue Liner Concrete Cap Chimney Approved Through Wall Installation 36 915mm Minimum...

Page 17: ...DS OF MAINTAINING VAPOUR BARRIER System A Minimum 3 5 in 90 mm thick brick masonry wall framed into combustible wall with a minimum of 12 in 305 mm brick separation from clay liner to combustibles Fir...

Page 18: ...ventilated air channels each 1 25 4 mm construction of sheet steel Chimney connector Masonry chimney constructed to NFPA 211 Chimney flue Minimum chimney clearance from masonry to sheet steel support...

Page 19: ...66 m or as per chimney manufacturers roof clearances whichever is greater NOTE Longer chimney lengths and different pitch flashings may be used Install all components to the connector or chimney manu...

Page 20: ...drill a corresponding hole in the closest exterior wall Install an approved 3 76mm inlet vent cap Attach the outside air adapter to the underside of the stove Connect the adapter to the inlet vent ca...

Page 21: ...rse the process to replace the baffle assembly Installation 1 Insert one half of baffle board above the two back baffle tubes inside the firebox slide over to the right and allow to rest on the baffle...

Page 22: ...10 2 Using the same 4 screws place the blower into the opening in the rear shield with the blower outlet pointing up Figure 11 3 Tighten the screws Blower Operation Proper blower speed matched with a...

Page 23: ...s Install each side brick insert the brick under the retaining flange near the front of the baffle air box on each side of the firebox and then slide the brick to the back of the unit Next install 3 f...

Page 24: ...See 1 2 3 above Low Heat Output 1 Wood is wet Use dry wood 2 Fire too small Build a larger fire 3 Draft too low Chimney plugged or restricted inspect and clean Won t Burn Overnight 1 Air control is s...