TN10 NA 080617-28
26
5055.549-A
Rating label location
The Rating label is located on the lower portion of the rear cover.
Rating Label
A.
8 IN. / 205 MM 8 IN. / 205 MM
B.
8 IN. / 205 MM
8 IN. / 205 MM
C.
6 IN. / 152 MM
6 IN. / 152 MM
D. 15-5/
8 IN. / 397 MM 15-5/8 IN. / 397 MM
E.
10-1/4 IN. / 260 MM
10-1/4 IN. / 260 MM
F.
13-1/4 IN. / 337 MM 13-1/4 IN. / 337 MM
A.
8 IN. / 205 MM
8 IN. / 205 MM
B.
6 IN. / 155 MM
6 IN. / 155 MM
C.
3IN. / 76 MM
3 IN. / 76 MM
D.
15-5/8 IN. / 394 MM 15-5/8 IN. / 394 MM
E.
8-1/4 IN. / 210 MM 8-1/4 IN. / 210 MM
F.
10-1/4 IN. / 279 MM 10-1/4 IN. / 279 MM
A.
8 IN. / 205 MM
B.
6 IN. / 155 MM
C.
3 IN. / 76 MM
D.
15-5/8 IN. / 394 MM
E.
8-1/4 IN. / 210 MM
F
10-1/4 IN. / 279 MM
CERTIFIED FOR CANADA
AND U.S.A.
- SERIES / SÉRIE:
A
MODEL
/ MODÈLE:
TN10
LISTED ROOM HEA
TER, SOLID FUEL
TYPE.
ALSO FOR USE IN MOBILE HOMES
TESTED T
O/ ÉPROUVÉ SELON: CAN/ULC S627-00
AND IN THE USA
CONFORMS
TO
UL
1482-201
1
•
INST
AL
L
AND USE IN
ACCORDANCE WITH THE MANUF
ACTURER’S INST
ALLA
TION
AND OPERA
TING
INSTRUCTIONS.
•
CONT
ACT LOCAL
BUILDING OR FIRE OFFICIALS
ABOUT RESTRICTIONS, INST
ALLA
TION PERMIT
AND
INSPECTION IN
YOUR
AREA.
•
DO NOT CONNECT THIS UNIT
TO
A
CHIMNEY
FLUE SER
VING
ANOTHER
APPLIANCE.
•
USE 6 INCH / 150MM DIAMETER MINIMUM 24 MSG BLACK OR LISTED CONNECT
OR.
•
CAN BE CONNECTED
TO
A
LINED MASONR
Y
CHIMNEY
SUIT
ABLE FOR USE WITH SOLID FUELS.
•
DO NOT OBSTRUCT THE SP
ACE BENE
AT
H THE HE
AT
ER.
•
SEE LOCAL
BUILDING CODE
AND MANUF
ACTURER'S INSTRUCTIONS FOR PRECAUTIONS REQUIRED
WHEN P
ASSING
A
CHIMNEY
THROUGH
A
COMBUSTIBLE
WA
LL
OR CEILING.
•
DO NOT
PA
SS
A
CHIMNEY
CONNECT
OR THROUGH
A
COMBUSTIBLE
WA
LL
OR CEILING.
•
MINIMUM CLEARANCE BETWEEN SINGLE
WA
LL
CHIMNEY
CONNECT
OR
AND COMBUSTIBLE MA
TE-
RIALS-18INCHES/455MM. CLEARANCE MA
Y
BE REDUCED BY
THE USE OF LISTED PIPE SHIELDS,
WA
LL
PROTECT
ORS OR OTHER MEANS
APPROVED BY
LOCAL
BUILDING OR FIRE OFFICIALS
.
•
COMPONENTS REQUIRED FOR MOBILE HOME
AND
ALCOVE INST
ALLA
TION: OUTSIDE
AIR KI
T.
B
OTH CHIMNEY
SYSTEM
AND CONNECT
OR MUST BE LISTED
TO
:
IN CANADA
- ULC S-641 LISTED CONNECT
OR
AND ULC-S-629 LISTED CHIMNEY
IN US
A
- UL-103 HT LISTED CONNECT
OR
AND CHIMNEY
•
USE COMPONENTS SPECIFIED IN P
ACIFIC ENERGY
INST
ALLA
TION INSTRUCTIONS.
•
OPTIONAL
COMPONENT - BLOWER(TRNO.19BLOW
A), F
AN ELECTRICAL
RA
TING: 1
15V
, 60HZ, .5
AM
P.
•
CAUTION: RISK OF EXCESSIVE TEMPER
AT
URES - KEEP
ASH DUM
P
CLOSED DURING FIRING OF THE
HEA
TER. • DO NOT ROUTE POWER CORD BENEA
TH HEA
TER.
•
OPER
AT
E ON
LY
WITH FEED DOOR CLOSED. OPEN
TO
FEED FIRE ON
LY
.
•
KEEP
FURNISHINGS
AND OTHER COMBUSTIBLE MA
TERIALS WELL
AW
AY
FROM HE
AT
ER.
•
REPLACE GLASS ON
LY
WITH CERAMIC GLASS.
HORIZON
TA
L
CONNECT
OR NOT PERMITTED IN MOBILE HOMES
AS TESTED - PIPE SHIELD MA
Y
BE REQUIRED BY
LOCAL
AUTHORITIES.
*
ALCOVE SIZE : DEPTH - 3 FT
. / .91 M MAX., HEIGHT 5 FT
. / 1.53 M MIN., WIDTH 38 IN. / .97 M MIN.
COMBUSTIBLE FLOOR MUST BE PROTECTED BY
A
CONTINUOUS NON-COMBUSTIBLE MA
TERIAL
EXTENDED
TO
THE FRONT
, SIDES
AND BACK
AS INDICA
TED.
•
FOR USE WITH SOLID WOOD FUEL
ON
LY
. ST
OVE DESIGNED
TO
BURN CORDWOOD ON
LY
. BURNING
OTHER MA
TERIALS MA
Y
CAUSE DAMAGE
TO
ST
OVE OR HOME.
• THIS WOOD HEA
TER NEEDS PERIODIC INSPECTION
AND REP
AIR FOR PROPER OPERA
TION. - CON-
SUL
T THE OWNER’S MANUAL
FOR FURTHER INFORMA
TION.
• IT IS
AGAINST FEDERAL
REGULA
TIONS
TO
OPERA
TE THIS WOOD HEA
TER IN
A
MANNER INCON-
SIST
ANT WITH THE OPERA
TING INSTRUCTIONS IN THE OWNER’S MANUAL
MINIMUM CLEARANCES
TO
COMBUSTIBLE MA
TERIALS/
DÉGAGEMENTS MINIMALES
AUX
MA
TÉRIAUX COMBUSTIBLES
DO NOT
REMOVE
THIS LABEL
RACCORD
VERTICAL
CONNECT
OR
RACCORD
HORIZONT
AL
CONNECT
OR
RESIDENTIAL
CLOSE CLEARANCE INST
ALLA
TION
USING DOUBLE W
ALL
CONNECT
OR/
INST
ALLA
TION
RÉSIDENTIELLE
A
VEC DÉGAGEMENT MINIMAL, UTILISANT
UN RACCORD DE MUR DOUBLE
RESIDENTIAL
INST
ALLA
TION
USING SINGLE W
ALL
CONNECT
OR/
INST
ALLA
TION RÉSIDENTIELLE UTILISANT UN
RACCORD DE MUR SIMPLE
IN CANADA
G.
18 INCHES / 457 MM
AU CANADA
H.
8 INCHES / 200 MM
I.
8 INCHES / 200 MM
IN U.S.A.
G.
16 INCHES / 405 MM
H.
3.5 INCHES / 89 MM
I.
0 INCHES / 0 MM
MOBILE
HOME INST
ALLA
TION
USING DOUBLE
WA
LL
CONNECT
OR/
INST
ALLA
TION
EN MAISON MOBILE UTILISANT
UN RACCORD DE MUR DOUBLE
E
TL#4001507
•
INST
ALLEZ ET UTILISEZ SELON LES INSTRUCTIONS D’INST
ALLA
TION ET D’OPÉR
AT
ION FOURNI
A
VEC
L’APP
AREIL..
•
CONT
ACTEZ LES OFFICIELS DE LA
CONSTRUCTION OU DE SER
VICE D’INCENDIE POUR DES INFORMA
TIONS QUANT
AUX RES-
TRICTIONS. PERMIS D’INST
ALLA
TION ET INSPECTIONS DANS VOTRE RÉGION.
•
NE RELIEZ
PA
S CET
APP
AREIL
À UN CONDUIT DE CHEMINÉE DESSER
V
ANT DÉJÀ UN
AUTRE
APP
AREIL
•
UTILISER UN TUY
AU DE RACCORDEMENT DE 6 PO (150 MM) DIAM., HOMOLOGUÉ OU NOIR 24
MSG (MIN.
)
•
PEUT ÊTRE CONNECTÉ À UNE CHEMINÉE DE MAÇONNERIE GAINÉ PRÊTE À
L’EMPLOI
A
VEC DES COMBUSTIBLES SOLIDES.
•
N’OBSTRUEZ P
AS L
’ESP
ACE SOUS LE CAISSON DU POÊLE
•
CONSUL
TEZ LE CODE LOCAL
DE CONSTRUCTION ET LES INSTRUCTIONS DU F
ABRICANT QUANT
AUX PRÉCAUTIONS À
PRENDRE LORSQUE VOUS F
AITES P
ASSER UNE CHEMINÉE À TRA
VERS D’UN MUR OU D’UN PLAFOND COMPOSÉS DE MA
TÉ-
RIAUX COMBUSTIBLES.
•
LE TUY
AU DE RACCORDEMENT DE CHEMINÉE NE DOIT
PA
S TRA
VERSER UN MUR OU PLAFOND EN MA
TÉRIAUX COMBUS-
TIBLES.
•
DÉGAGEMENT MINIMA
L
ENTRE UN RACCORDEMENT DE CHEMINÉE À SIMPLE P
AROIS ET UN MUR ET
TO
UT MA
TÉRIEL
COM-
BUSTIBLE - 18 POUCES / 455 mm. CE DÉGAGEMENT PEUT ÊTRE RÉDUIT
EN UTILISANT DES PROTECTEURS DE TUY
AUX CLAS-
SÉS, PROTECTEURS DE MUR OU
AUTRES MOYENS
APPROUVÉS P
AR LES OFFICIELS DE LA
CONSTRUCTION OU DU SER
VICE
D’INCENDIE DE VOTRE RÉGION.
CONNECTEUR HORIZON
TA
L
NON PERMIS DANS MAISONS MOBILES
•
PIÈCES REQUISES POUR INST
ALLA
TION EN MAISON MOBILE OU EN
ALCÔVE: PRISE D’AIR EXTÉRIEUR
ET L
’UN DES RACCORDS SUIV
ANTS: EN COMBINAISON
A
VEC
L’
UN DES SYSTÈMES DE CHEMINÉE COM-
PA
TIBLES SUIV
ANTS:
CANADA-TUY
AU DE RACCORDEMENT HOMOLOGUÉ ULC S-641 ET CHEMINÉE HOMOLOGUÉE ULC S-629.
ÉT
AT
S-UNIS - TUY
AU DE RACCORDEMENT ET CHEMINÉE HOMOLOGUÉS UL-103HT
.
• COMPOSANTS OPTIONNELS: VENTILA
TEUR (WODC.BLOW),
ALIMENT
A
TION ÉLECTRIQUE DU VENTILA
TEUR : 1
15
V,
60 HZ, 0.5
AMP
. LE CORDON D’ALIMENT
A
TION ÉLECTRIQUE NE DOIT
PA
S ÊTRE PLACÉ SOUS LE POÊLE.
LE FIL
ÉLECTRIQUE NE DOIT
PA
S ÊTRE PLACÉ SOUS LE POÊL
E
•
AT
TENTION: RISQUE DE TEMPÉR
AT
URES EXCESSIVES - GARDES LE TIROIR DE CENDRES FERMÉ PENDANT
L’
ALLUMAGE DU
POÈLE.
•
OPÉREZ SEULEMENT LORSQUE LA
PORTE D’ALIMEN
TA
TION EST FERMÉE. • OUVREZ SEULEMENT POUR
ALIMENTER LE FEU.
•
GARDEZ LES MEUBLES ET
AUTRES MA
TÉRIAUX COMBUSTIBLES BIEN ÉLOIGNÉS DU POÊLE.
•
REMPLACES LA
VITRE
A
VEC UNIQUEMENT DE LA
VITRE CÉRAMIQUE.
CONNECTEUR HORIZONT
AL
NON PERMIS DANS MAISONS MOBILES
TEL
QUE TESTÉ: UN ISOLANT THERMIQUE POUR TUY
AU PEUT ÊTRE EXIGÉ P
AR LES
AUT
ORITÉS LOCALES. * DIMENSIONS
D’ALCÔVE EN MA
TÉRIAUX COMBUSTIBLES: PROFONDEUR MAX.: 3 PIEDS (0,91 M), HAUTEUR MIN.: 7 PIEDS (2,1 M), LARGEUR
MIN.: 43 PO (1,09 M).
LE PLANCHER COMBUSTIBLE DOIT ÊTRE PROTÉGÉ P
AR UN MA
TÉRIEL
NON-COMBUSTIBLE T
OUT D’UNE PIÈCE QUI DOIT
S’ÉTENDRE DE P
AR LE DEV
ANT
, LES COTÉS ET L
’ARRIÈRE TEL
QU’INDIQUÉ.
·
POUR UTILISA
TION
A
VEC BOIS SOLIDE SEULEMEN
T.
LE POELE CONÇU POUR BRÛLER BOIS DE CORDE
SEULEMENT
. LA
COMBUSTION D’AUTRES MA
TÉRIELS PEUT
.
CET
APPRAREIL
DE CHAUFF
AGE
AU BOIS DOIT F
AIRE L
’OBJETD’ENTRETIENS ET D’INSPECTIONS
P
É
RIODIQUES POUR
UN FONCTIONNEMENT
AD
É
QUA
T.
CONSUL
TEZ LE MANUE
L
D’UTILISA
TION POUR PLUS D’INFORMA
TION.
A.
SIDEW
ALL
TO
UNIT/
MUR DE CÔTE /
APP
AREIL
B.
BACKW
ALL
TO
UNIT/
M
UR DE FOND /
APP
AREIL
C.
CORNER
TO
UNIT/
COIN /
APP
AREIL
D.
SIDEW
ALL
TO
CONNECT
OR/
MUR DE CÔTE / RACCORD
E.
BACKW
ALL
TO
CONNECT
OR/
MUR DE FOND / RACCORD
F.
CORNER
TO
CONNECT
OR/
COIN / RACCORD
BACK I
HEA
TER
G
SIDE
H
FRONT
SIDE
H
COTE
COTE
DEV
ANT
POELE
DOS
RACCORD
VERTICAL
CONNECT
OR
RACCORD
HORIZONT
AL
CONNECT
OR
MADE IN CANADA/
F
ABRIQUÉ
AU CANADA
J
F
M
A
M
J
J
A
S
O
N
D
2
017
2018
2019
2020
2021 2022
DA
TE OF MANUF
ACTURE/
DA
TE DE MANUF
ACTURE
TN10-1
5050.849-A
060217
MANUF
ACTURED BY/
F
ABRIQUÉ P
AR:
P
ACIFIC ENERGY
FIREPLACE PRODUCTS
LT
D.
2975
ALLENBY
RD., DUNCAN, BC V9L
6V8
HOT WHILE IN OPERA
TION. DO NOT T
OUCH. KEEP
CHILDREN, CLOTHING
AND FURNITURE
AW
AY
. CONT
ACT MA
Y
CAUSE SKIN BURNS. SEE NAMEPL
AT
E
AND INSTRUCTIONS.//
CHAUD LORSQU’EN OPÉRA
TION. NE P
AS T
OUCHER, TENEZ LES
ENF
ANTS ET LES VÊTEMENTS BIEN À
L’
ÉCART
. LE CONT
ACT PEUT CAUSER DES BRÛLURES
À LA
PEAU. CONSUL
TEZ LA
PLAQUE CE CONSTRUCTEUR ET LES INSTRUCTIONS.
CAUTION
ADJACENT
W
ALL
BACK W
ALL
D
A
SIDE WALL
B
E
ADJACENT W
ALL
F
C
MUR COTE
MUR
ARRIERE
MUR ADJACENT
MUR
ADJACENT
SN-
410
(T
ype 1 fl
oor
pr
ot
ect
or - ap-
p
rov
ed t
o UL1
61
8)
Minim
um 20G
A
st
eel
U.S. ENVIRONMENT
AL
PROTECTION
AGENCY
.
Certifi
ed to comply with 2020 crib wood particulate emission standards,
using test Method 28R//
Certifi
é conforme aux normes sur les émissions de
particules de 2020.
1.4 g/hr