FIGURE 3.4
EXAMPLE WIRING DIAGRAMS
TI500
A
D
G
E
B
C
28VDC
Case attached to airframe
INVERTER ENABLE
(always active)
28VDC
PROTECTION
&
GFI
OUTLETS
ON
OFF
TI500
30A
30A
3rd Party
equipment
Optional 5A
Circuit Breaker
A
D
G
E
B
C
Case attached to airframe
A
D
G
E
B
C
A
D
G
E
B
C
(not supplied)
Optional 1-2A
Circuit Breakers
110VAC Outlet(s)
(not supplied)
INVERTER ENABLE
(Remote ON/OFF)
3
2
1
A
B
GFI
Ground Fault Indicator
(not supplied)
Optional
Notes:
1. Wiring diagrams above represent various examples of typical installations.
2. Recommended to attach case to metal aircraft structure.
3. Recommended outlet protection may consist of either:
A. single 5A circuit breaker for all outlet(s) (single or double pole breaker),
OR
B. 1-2A circuit breakers for each outlet
4. For Remote On/Off operation, return line can be configured in
one
of three ways:
1. return line connected to pin G
2. return line connceted to pin D
3. return line connected to aircraft ground