background image

 

 

Initial set-up information  

 

Gently remove the model from the carrier case and remove the protective foam placed 
under the manikin head 

 

 

Secure the manikin to a suitable surface by adjusting the screw on the suction cups 
(surface must be non-porous to ensure sufficient suction)

 

 

Loosen the neck locks to provide easier head movement if required. Re-tighten the neck 
lock again once the head is in the desired position

 

 

Check the volume of air in the tongue is sufficient, it can be inflated or deflated by a 
syringe to adjust the difficulty during intubation if desired

 

 

Please ensure two lung bags and one stomach bag are attached to the airway and 
oesophagus respectively 

 

 

Spray generous amounts of lubrication provided with the model (TL001) on the airway 
and equipment prior to use

 

 

List of procedures facilitated by the AirSim Bronchi 

 

Diagnostic bronchoscopy 

 

Lung isolation techniques using left and right endo-bronchial tubes and bronchial 
blockers 

 

Lung suctioning techniques 

 

Single naso-tracheal intubation 

 

Bag valve mask (BVM) ventilation techniques 

 

Full range of supraglottic devices 

 

Direct laryngoscopy 

 

Endotracheal tube insertion 

 

Awake fibre optic examination 

 

Single lung isolation techniques 

 

Combi tube insertion 

 

Care and maintenance 

Store in clean, dry conditions away from heat and direct sunlight; avoid contact with metals, 
solvents, oils or greases and strong detergents. When the product is not in use please store 
in the black carrier case provided.  

Thoroughly wash the AirSim airway in warm water. Please use warm soapy water or 
something similar until all visible foreign matter and residue is removed. 

Summary of Contents for AirSim Bronchi

Page 1: ... constructed AirSim airway for realistic feedback during airway management procedures Visually and anatomically correct the nasal cavity and airway include important internal landmarks for training in endo tracheal and nasotracheal intubations Additionally the model features anatomically correct bronchi to the 4th generation for realistic bronchoscopy training ...

Page 2: ...2 Contents Product specifications 3 Package contents 3 Recommended equipment sizes 3 Initial set up information 4 List of procedures facilitated by the AirSim Bronchi 4 Care and maintenance 4 Warranty 5 ...

Page 3: ...tents 1 AirSim Bronchi ready to use AA51100 1 AirSim Bronchi carrier case ABAG01 1 USB pen drive user manual 100ml bottle of lubrication TL001 Recommended equipment sizes 7 0 7 5mm ID for nasal intubation 8 0 9 0mm ID for oral intubation Sizes 3 5 for LMA laryngeal masks Similar respective sizes for other supraglottic devices Size 35F 37F for endo bronchial tubes ...

Page 4: ...tion provided with the model TL001 on the airway and equipment prior to use List of procedures facilitated by the AirSim Bronchi Diagnostic bronchoscopy Lung isolation techniques using left and right endo bronchial tubes and bronchial blockers Lung suctioning techniques Single naso tracheal intubation Bag valve mask BVM ventilation techniques Full range of supraglottic devices Direct laryngoscopy ...

Page 5: ...orp warrants this unit to be free of defects in materials and workmanship and to give satisfactory service for a period of 1 year from the date of delivery This ensures that our customers receive maximum coverage on each product If the unit should malfunction it must be returned to the factory for evaluation Upon examination by TruCorp if the unit is found to be defective it will be repaired or re...

Page 6: ...6 ...

Reviews: